Product details
Product Overview
- Product Model: FC-D980
- Product Brand: AERA
- Product Series: FC-D980 Series (Digital, piezoelectric, metal-sealed)
- Core Identity: A multi-gas, multi-range digital mass flow controller.
- Valve Type: Piezoelectric valve, normally-open or normally-closed.
- Best Fit: Semiconductor process tools that need fast, stable gas control.
- Key Benefit: High accuracy, strong repeatability and long-term zero stability.
- Typical Applications:
- CVD and PVD
- Etch and diffusion
- Ion implantation
- Sputtering
Technical Data
- Brand and Model: AERA FC-D980
- Full-Scale Flow Range: 3 sccm to 5 slm (N2 equivalent, multi-gas and multi-range)
- Accuracy:
- Within +/-1% of set point from 25% to 100% of full scale
- Within +/-0.25% of full scale from 2% to 25% of full scale
- Repeatability: Within +/-0.2% of full scale
- Response Time: Under 1 sec to within +/-2% of set point; actual-flow settling time is 0.5 sec between set points
- Control Range / Turndown: 2% to 100% of full scale
- Zero Stability: Less than 0.5% of full-scale flow over one year
- Gas Type: Multi-gas, field programmable
- Stores up to eight gases
- Up to 11 calibration points per gas
- Operating Pressure:
- Differential pressure: 7 to 40 psiD (49 to 275 kPaD)
- Max operating pressure: 70 psig (490 kPaG)
- Proof pressure: 140 psig (981 kPaG)
- Wetted Materials: Double VAR type 316L stainless steel; all gas-wetted surfaces electropolished and ultra-cleaned to 1 Ra (0.025 um)
- Seals: All-metal (metal seal)
- Electrical Interface: Analog 0 to 5 VDC input/output plus RS-485 (RS-232 with converter); 20-pin Honda connector
- Heated Option: No (standard unheated version)
- Operating Temperature: 5 to 45 degrees C (41 to 113 degrees F)
- Dimensions: 129 x 38 x 124 mm (H x W x D; port-to-port 124 mm; see outline drawing)
- Weight: 1.0 kg (2.2 lb)
- Power Supply:
- +15 VDC +/-2% at 120 mA min
- -15 VDC +/-2% at 50 mA min
- 1.3 W max
- Leak Integrity: 1 x 10^-10 atm-cc/sec (He) max
Installation Guide
- Mount the unit in the gas line with the flow direction marked on the body.
- Keep the differential pressure between 7 and 40 psiD for stable control.
- Do not exceed 70 psig operating pressure.
- Use the 20-pin Honda connector for power and signal wiring.
- Connect RS-485 for digital control; use a converter for RS-232.
- Allow 5 to 45 degrees C ambient temperature around the device.
- Keep the inlet gas clean and dry to protect the metal seat.
Setup and Maintenance Convenience
- Field-programmable gas settings save changeover time.
- Eight stored gases and 11 calibration points per gas cut setup work.
- Built-in alarm and diagnostic functions help fast fault finding.
- All-metal seal design supports long service life.
- Electropolished, ultra-clean wetted parts reduce particle risk.
- Zero stability under 0.5% per year lowers re-calibration frequency.
Compatibility Notes
- Works with analog 0 to 5 VDC control systems.
- Supports RS-485 digital networks; RS-232 works with a converter.
- Fits multi-gas tools that need several gas recipes on one unit.
- Suits semiconductor tools such as CVD, PVD, etch and implant.
- Use N2-equivalent flow data when comparing ranges.
Certification and Compliance
- RoHS compliant.
- Settling time referenced to SEMI E17-91.
- Leak integrity tested to 1 x 10^-10 atm-cc/sec (He) max.
Packing List
- 1 x AERA FC-D980 mass flow controller
- 1 x 20-pin Honda mating connector
- 1 x Outline drawing and wiring reference
- 1 x Calibration and compliance document set
FAQ
- Q: Can one unit handle different gases?
- A: Yes. The unit stores up to eight gases and 11 calibration points per gas.
- Q: How fast does it reach a new set point?
- A: It settles within +/-2% in under 1 second; step-to-step settling is about 0.5 second.
- Q: Does it need a heated version?
- A: The standard model is unheated. Choose heating only if your process gas needs it.
- Q: What pressure should I supply?
- A: Keep differential pressure between 7 and 40 psiD, and stay under 70 psig.
- Q: How often should I re-calibrate?
- A: Zero drift stays under 0.5% of full scale per year, so yearly checks usually suffice.
- Q: From experience, what causes unstable flow?
- A: Most cases come from low differential pressure or dirty supply gas. Check both first.
- Q: Can I swap it into an existing RS-485 line?
- A: Yes, it supports RS-485 directly. Use a converter only for RS-232 hosts.














There are no reviews yet.