Product details
Product Overview
- Model E94ASHE0174 is a Lenze Servo Drives 9400 HighLine Single Drive axis module.
- It suits cabinet mounting and controls a 7.5 kW 4-pole asynchronous motor in the 400 V class.
- Rated output current reaches 20.6 A at 4 kHz switching frequency.
- Maximum output current reaches 30.9 A. Short-term peak reaches 49.5 A.
- The drive offers a 3× overload factor for demanding motion cycles.
- Built-in CANopen supports fast integration into machine networks.
- Two extension slots accept communication or extension modules from the E94AYC family.
- One memory slot and one safety slot support flexible machine design.
- A USB diagnostic port works through the E94AZCUS adapter.
- This module belongs to the active L-force range. Official catalogue pages remain live as of October 2026.
Technical Specifications
- Brand: Lenze
- Model: E94ASHE0174
- Series: Servo Drives 9400 HighLine Single Drive
- Module type: Single-axis drive module for cabinet mounting
- Rated motor power: 7.5 kW nominal, ASM 4-pole, 400 V class
- Rated output current: 20.6 A at 4 kHz switching frequency
- Maximum output current: 30.9 A
- Maximum short-term output current: 49.5 A
- Overload factor: 3
- Rated mains current: 15 A with mains choke; 21 A without mains choke
- Rated DC-bus current: 25.7 A
- Power loss: 380 W
- Supply voltage: 3/PE AC 180 V to 550 V, 45 Hz to 65 Hz
- Alternative DC supply: DC 260 V to 775 V
- Operating temperature: -10 °C to +55 °C
- Temperature derating: Reduce rated output current by 2.5 % per °C above +45 °C
- Storage temperature: -25 °C to +60 °C
- Transport temperature: -25 °C to +70 °C
- Site altitude: Up to 4000 m AMSL
- Altitude derating: Reduce rated output current by 5 % per 1000 m above 1000 m
- Vibration resistance: Class 2M2; 10 Hz to 57 Hz at ±0.075 mm; 57 Hz to 150 Hz at 1.0 g
- Climatic class: 3K3 per EN 60721-3-3
- Protection rating: IP20 per EN 60529; NEMA 250 type 1
- Dimensions: 350 mm × 120 mm × 288 mm, height includes 507 installation backplane
- Weight: 8.1 kg
Installation Guide
- Mount the module inside a cabinet with the 507 installation backplane.
- Keep the IP20 enclosure closed and protect the drive from dust and moisture.
- Use a mains choke when you need the lower 15 A rated mains current.
- Respect clearance for airflow. The drive dissipates 380 W as heat.
- Connect the CANopen port to the machine network.
- Use the USB diagnostic port with the E94AZCUS adapter for setup.
- Fit communication, memory, or safety modules only in the designated slots.
- Check supply voltage against the 180 V to 550 V AC range before power-up.
Commissioning and Maintenance
- Commission the drive with Lenze engineering tools through the diagnostic interface.
- Set motor data for the 7.5 kW 4-pole asynchronous motor before the first run.
- Monitor overload events. The 3× overload factor supports short peaks, not continuous excess.
- Check fan paths and cabinet filters at regular service intervals.
- Verify terminal torque and cable condition during planned downtime.
- Keep spare extension modules from the E94AYC family for fast replacement.
Compatibility Notes
- Works with Lenze 9400 HighLine Single Drive cabinet systems.
- Supports CANopen as the onboard fieldbus.
- Accepts two E94AYC communication or extension modules.
- Supports one memory module and one safety module.
- Fits 400 V class 4-pole asynchronous motors up to 7.5 kW nominal.
- Use the E94AZCUS adapter for USB diagnostics.
Certifications and Compliance
- Protection rating follows EN 60529 and NEMA 250 type 1.
- Climatic class follows EN 60721-3-3 class 3K3.
- Storage class follows EN 60721-3-1 class 1K3.
- Transport class follows EN 60721-3-2 class 2K3.
- Vibration testing follows EN 60068-2-6 and Germanischer Lloyd rules.
- Audit status: OFFICIAL_VERIFIED.
Packing List and Warranty
- One Lenze E94ASHE0174 drive module.
- One installation backplane, 507 type, as described.
- Documentation set for setup and safety.
- 12-month warranty covers the module.
- Orders ship within 12 to 24 hours after confirmation.
- Express options include FedEx, UPS, and DHL.
Expert Review
- The E94ASHE0174 fits machine builders who need one compact axis module.
- Its 3× overload factor helps with high starting torque and short peaks.
- CANopen keeps wiring simple and cuts integration time.
- Two extension slots give room for fieldbus changes and safety upgrades.
- The wide 180 V to 550 V AC input range suits many global grids.
- Derating rules are clear, so engineers can plan hot cabinets and high sites.
- One weak point: IP20 protection limits use to clean cabinets.
Manager’s Insight
- This module is a strong fit for 7.5 kW asynchronous motor axes in series machines.
- Stock the E94AYC modules and the E94AZCUS adapter to shorten service stops.
- Offer the mains choke option to customers who want the lower 15 A mains current.
- Highlight the 12 to 24 hour dispatch window for urgent retrofit jobs.
- Use FedEx, UPS, or DHL tracking to set clear delivery expectations.
Best Fit Devices and Applications
- Packaging lines with 7.5 kW asynchronous feed axes.
- Material handling conveyors and indexing stations.
- Printing and paper machines with cabinet-mounted drives.
- Woodworking and metal forming machines with CANopen networks.
- Retrofit projects that replace older 400 V class drives.
- Machines that need a safety slot for future upgrades.
FAQ
- Q: What motor does this module drive?
A: It drives a 7.5 kW 4-pole asynchronous motor in the 400 V class. - Q: How much peak current can it deliver?
A: Short-term output reaches 49.5 A, with a 3× overload factor. - Q: Which fieldbus comes built in?
A: CANopen is onboard. Two slots accept E94AYC modules for more options. - Q: Can I use it above +45 °C?
A: Yes. Derate rated output current by 2.5 % per °C above +45 °C. - Q: What about high installation sites?
A: The drive works up to 4000 m AMSL. Derate 5 % per 1000 m above 1000 m. - Q: Is the enclosure sealed?
A: No. It carries IP20 and NEMA 250 type 1 ratings, so mount it in a cabinet. - Q: How fast do orders ship?
A: Orders leave within 12 to 24 hours by FedEx, UPS, or DHL. - Q: What warranty applies?
A: A 12-month warranty covers the module. - Q: What is the key experience tip?
A: Set motor data before the first run and log overload events during ramp-up. - Q: How do I choose the right variant?
A: Match motor power, mains current with or without a choke, and the fieldbus you need. - Q: Should I add a mains choke?
A: Choose it when grid conditions or site rules call for the lower 15 A mains current. - Q: When should I pick another module?
A: Pick a larger frame when continuous current exceeds 20.6 A or the load needs more peaks.
Buying Guide
- Confirm the motor is a 4-pole asynchronous type at 7.5 kW nominal.
- Check mains current needs: 15 A with choke or 21 A without.
- List the fieldbus and safety modules you plan to add.
- Plan cabinet cooling for the 380 W power loss.
- Check site altitude and ambient heat against the derating rules.
- Order the E94AZCUS adapter for USB diagnostics.
- Ask for the 12 to 24 hour dispatch option on urgent builds.
Contact Information
- Email: sales@powergearx.com
- Phone and WhatsApp: +86 18030005825
Copyright © 2026 Powergear X Automation Limited. All rights reserved.