Over 50,000 hot-selling automation module components.

E94ASHE0174 Lenze 9400 Single Drive CANopen Module

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: E94ASHE0174

Product details

Product Overview

  • Model E94ASHE0174 is a Lenze Servo Drives 9400 HighLine Single Drive axis module.
  • It suits cabinet mounting and controls a 7.5 kW 4-pole asynchronous motor in the 400 V class.
  • Rated output current reaches 20.6 A at 4 kHz switching frequency.
  • Maximum output current reaches 30.9 A. Short-term peak reaches 49.5 A.
  • The drive offers a 3× overload factor for demanding motion cycles.
  • Built-in CANopen supports fast integration into machine networks.
  • Two extension slots accept communication or extension modules from the E94AYC family.
  • One memory slot and one safety slot support flexible machine design.
  • A USB diagnostic port works through the E94AZCUS adapter.
  • This module belongs to the active L-force range. Official catalogue pages remain live as of October 2026.

Technical Specifications

  • Brand: Lenze
  • Model: E94ASHE0174
  • Series: Servo Drives 9400 HighLine Single Drive
  • Module type: Single-axis drive module for cabinet mounting
  • Rated motor power: 7.5 kW nominal, ASM 4-pole, 400 V class
  • Rated output current: 20.6 A at 4 kHz switching frequency
  • Maximum output current: 30.9 A
  • Maximum short-term output current: 49.5 A
  • Overload factor: 3
  • Rated mains current: 15 A with mains choke; 21 A without mains choke
  • Rated DC-bus current: 25.7 A
  • Power loss: 380 W
  • Supply voltage: 3/PE AC 180 V to 550 V, 45 Hz to 65 Hz
  • Alternative DC supply: DC 260 V to 775 V
  • Operating temperature: -10 °C to +55 °C
  • Temperature derating: Reduce rated output current by 2.5 % per °C above +45 °C
  • Storage temperature: -25 °C to +60 °C
  • Transport temperature: -25 °C to +70 °C
  • Site altitude: Up to 4000 m AMSL
  • Altitude derating: Reduce rated output current by 5 % per 1000 m above 1000 m
  • Vibration resistance: Class 2M2; 10 Hz to 57 Hz at ±0.075 mm; 57 Hz to 150 Hz at 1.0 g
  • Climatic class: 3K3 per EN 60721-3-3
  • Protection rating: IP20 per EN 60529; NEMA 250 type 1
  • Dimensions: 350 mm × 120 mm × 288 mm, height includes 507 installation backplane
  • Weight: 8.1 kg

Installation Guide

  • Mount the module inside a cabinet with the 507 installation backplane.
  • Keep the IP20 enclosure closed and protect the drive from dust and moisture.
  • Use a mains choke when you need the lower 15 A rated mains current.
  • Respect clearance for airflow. The drive dissipates 380 W as heat.
  • Connect the CANopen port to the machine network.
  • Use the USB diagnostic port with the E94AZCUS adapter for setup.
  • Fit communication, memory, or safety modules only in the designated slots.
  • Check supply voltage against the 180 V to 550 V AC range before power-up.

Commissioning and Maintenance

  • Commission the drive with Lenze engineering tools through the diagnostic interface.
  • Set motor data for the 7.5 kW 4-pole asynchronous motor before the first run.
  • Monitor overload events. The 3× overload factor supports short peaks, not continuous excess.
  • Check fan paths and cabinet filters at regular service intervals.
  • Verify terminal torque and cable condition during planned downtime.
  • Keep spare extension modules from the E94AYC family for fast replacement.

Compatibility Notes

  • Works with Lenze 9400 HighLine Single Drive cabinet systems.
  • Supports CANopen as the onboard fieldbus.
  • Accepts two E94AYC communication or extension modules.
  • Supports one memory module and one safety module.
  • Fits 400 V class 4-pole asynchronous motors up to 7.5 kW nominal.
  • Use the E94AZCUS adapter for USB diagnostics.

Certifications and Compliance

  • Protection rating follows EN 60529 and NEMA 250 type 1.
  • Climatic class follows EN 60721-3-3 class 3K3.
  • Storage class follows EN 60721-3-1 class 1K3.
  • Transport class follows EN 60721-3-2 class 2K3.
  • Vibration testing follows EN 60068-2-6 and Germanischer Lloyd rules.
  • Audit status: OFFICIAL_VERIFIED.

Packing List and Warranty

  • One Lenze E94ASHE0174 drive module.
  • One installation backplane, 507 type, as described.
  • Documentation set for setup and safety.
  • 12-month warranty covers the module.
  • Orders ship within 12 to 24 hours after confirmation.
  • Express options include FedEx, UPS, and DHL.

Expert Review

  • The E94ASHE0174 fits machine builders who need one compact axis module.
  • Its 3× overload factor helps with high starting torque and short peaks.
  • CANopen keeps wiring simple and cuts integration time.
  • Two extension slots give room for fieldbus changes and safety upgrades.
  • The wide 180 V to 550 V AC input range suits many global grids.
  • Derating rules are clear, so engineers can plan hot cabinets and high sites.
  • One weak point: IP20 protection limits use to clean cabinets.

Manager’s Insight

  • This module is a strong fit for 7.5 kW asynchronous motor axes in series machines.
  • Stock the E94AYC modules and the E94AZCUS adapter to shorten service stops.
  • Offer the mains choke option to customers who want the lower 15 A mains current.
  • Highlight the 12 to 24 hour dispatch window for urgent retrofit jobs.
  • Use FedEx, UPS, or DHL tracking to set clear delivery expectations.

Best Fit Devices and Applications

  • Packaging lines with 7.5 kW asynchronous feed axes.
  • Material handling conveyors and indexing stations.
  • Printing and paper machines with cabinet-mounted drives.
  • Woodworking and metal forming machines with CANopen networks.
  • Retrofit projects that replace older 400 V class drives.
  • Machines that need a safety slot for future upgrades.

FAQ

  • Q: What motor does this module drive?
    A: It drives a 7.5 kW 4-pole asynchronous motor in the 400 V class.
  • Q: How much peak current can it deliver?
    A: Short-term output reaches 49.5 A, with a 3× overload factor.
  • Q: Which fieldbus comes built in?
    A: CANopen is onboard. Two slots accept E94AYC modules for more options.
  • Q: Can I use it above +45 °C?
    A: Yes. Derate rated output current by 2.5 % per °C above +45 °C.
  • Q: What about high installation sites?
    A: The drive works up to 4000 m AMSL. Derate 5 % per 1000 m above 1000 m.
  • Q: Is the enclosure sealed?
    A: No. It carries IP20 and NEMA 250 type 1 ratings, so mount it in a cabinet.
  • Q: How fast do orders ship?
    A: Orders leave within 12 to 24 hours by FedEx, UPS, or DHL.
  • Q: What warranty applies?
    A: A 12-month warranty covers the module.
  • Q: What is the key experience tip?
    A: Set motor data before the first run and log overload events during ramp-up.
  • Q: How do I choose the right variant?
    A: Match motor power, mains current with or without a choke, and the fieldbus you need.
  • Q: Should I add a mains choke?
    A: Choose it when grid conditions or site rules call for the lower 15 A mains current.
  • Q: When should I pick another module?
    A: Pick a larger frame when continuous current exceeds 20.6 A or the load needs more peaks.

Buying Guide

  • Confirm the motor is a 4-pole asynchronous type at 7.5 kW nominal.
  • Check mains current needs: 15 A with choke or 21 A without.
  • List the fieldbus and safety modules you plan to add.
  • Plan cabinet cooling for the 380 W power loss.
  • Check site altitude and ambient heat against the derating rules.
  • Order the E94AZCUS adapter for USB diagnostics.
  • Ask for the 12 to 24 hour dispatch option on urgent builds.

Contact Information

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE94ASHE0174
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E94ASHE0174 Lenze 9400 Single Drive CANopen Module”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart