Product details
Product Overview
- Model E94AMHE0174 is a Lenze 9400 HighLine MultiDrive axis module.
- It drives a 7.5 kW 4-pole asynchronous motor in the 400 V class.
- It mounts in a DC-bus cabinet and saves panel space.
- Rated output current is 20.6 A at 4 kHz switching frequency.
- Max output current reaches 30.9 A. Short-term peak reaches 49.5 A.
- Overload factor is 3. This handles heavy starts with confidence.
- Built-in CANopen port supports fast fieldbus integration.
- Two extension slots accept E94AYC communication modules.
- One memory slot and one safety slot are ready for expansion.
- This module suits multi-axis machines that share one DC bus.
- Typical uses include packaging, printing, textile and handling systems.
- It also fits palletizers, winders and continuous web lines.
Key Technical Data
- Brand: Lenze
- Model: E94AMHE0174
- Series: Servo Drives 9400 HighLine MultiDrive
- Module type: Axis module for DC-bus cabinet mounting
- Rated motor power: 7.5 kW nominal, ASM 4-pole, 400 V class
- Rated output current: 20.6 A nominal at 4 kHz
- Max output current: 30.9 A maximum
- Max short-term output current: 49.5 A maximum short-term
- Overload factor: 3
- Rated DC-bus current: 25.7 A nominal
- Power loss: 320 W
- Supply voltage: DC 260 V to 775 V, DC-bus operation
- Built-in port: CANopen on board
- Diagnostic port: USB via E94AZCUS adapter
- Protocols: CANopen
- Expansion: Two E94AYC slots, one memory slot, one safety slot
- Operating temperature: -10 °C to +55 °C, class 3K3
- Current derating: 2.5 % per °C above +45 °C
- Storage temperature: -25 °C to +60 °C, class 1K3
- Transport temperature: -25 °C to +70 °C, class 2K3
- Site altitude: up to 4000 m AMSL
- Altitude derating: 5 % per 1000 m above 1000 m
- Vibration resistance: class 2M2, EN 60721-3-2 and EN 60068-2-6
- Humidity: climatic class 3K3, no specific %RH published
- Protection rating: IP20 per EN 60529, NEMA 250 type 1
- Dimensions H x W x D: 350 mm with 507 backplane x 120 mm x 288 mm
- Weight: 8.1 kg
Installation Guide
- Mount the module on the 507 installation backplane inside the cabinet.
- Keep the IP20 enclosure closed during operation.
- Connect the DC bus within 260 V to 775 V. Check polarity first.
- Use shielded motor cables. Keep them short and well grounded.
- Route CANopen wiring away from motor power cables.
- Respect clearance above and below the module for airflow.
- Derate current 2.5 % per °C when cabinet air exceeds +45 °C.
- Derate current 5 % per 1000 m above 1000 m site altitude.
- Tighten terminals to the torque stated in the Lenze manual.
- Verify PE bonding before you apply DC-bus power.
Commissioning and Maintenance
- Use the USB diagnostic port with the E94AZCUS adapter for setup.
- Lenze engineering tools load parameters quickly over this port.
- Set motor data and switching frequency before the first run.
- Run an autotune cycle to match the 4-pole motor.
- Check CANopen node ID and baud rate twice before power-up.
- Monitor DC-bus current and heatsink temperature during trials.
- Clean air filters on a fixed schedule. Dust raises internal temperature.
- Inspect fan and cable shields every six months.
- Replace worn fans early. Heat is the main lifetime factor.
- Store spare modules in a dry place within -25 °C to +60 °C.
Compatibility Notes
- Works inside the Lenze 9400 HighLine MultiDrive system.
- Pairs with E94AYC communication and extension modules.
- Uses the E94AZCUS adapter for USB diagnostics.
- Fits 507 installation backplane cabinets.
- Designed for 4-pole asynchronous motors in the 400 V class.
- Speaks CANopen natively. Other protocols need an E94AYC module.
- Shares one DC bus with other 9400 MultiDrive axis modules.
- Check firmware version before you swap modules between machines.
Certifications and Standards
- IP20 per EN 60529 and NEMA 250 type 1.
- Climate classes 3K3, 1K3 and 2K3 per EN 60721-3.
- Vibration class 2M2 per EN 60721-3-2.
- Operation vibration per EN 60068-2-6.
- Marine vibration follows Germanischer Lloyd limits.
- Lifecycle status: active L-force range. Verified 2026-10.
- Audit status: OFFICIAL_VERIFIED.
Packing List and Warranty
- One E94AMHE0174 axis module.
- One printed quick-start sheet. Full manual is online.
- Protective carton with anti-static wrap.
- 12-month warranty covers material and workmanship.
- Orders ship within 12 to 24 hours on business days.
- Express options: FedEx, UPS and DHL.
- Tracking number goes out the same day we ship.
- Questions? Email sales@powergearx.com.
- Call or chat +86 18030005825 on WhatsApp.
Expert Review
- The E94AMHE0174 is a strong pick for shared DC-bus cabinets.
- Its 3x overload factor handles peak torque without oversizing.
- 20.6 A rated current covers most 7.5 kW 4-pole motor duties.
- On-board CANopen cuts wiring and startup time.
- Two extension slots keep future protocol upgrades open.
- The 320 W loss is moderate. Plan cabinet cooling early.
- Above +45 °C, apply the 2.5 %/°C derating without fail.
- High-altitude sites need the 5 %/1000 m derating too.
- USB diagnostics make fault finding fast and simple.
- Overall, it is a reliable module for demanding multi-axis lines.
Manager’s Insight
- Stock this module if your customers run 9400 MultiDrive cabinets.
- It is a common spare. Downtime cost is high on multi-axis lines.
- Bundle it with E94AYC modules for faster project quotes.
- Offer the E94AZCUS adapter. It raises setup satisfaction.
- Most returns come from wrong firmware. Confirm version before shipping.
- Keep two units on hand for packaging and printing clients.
- Fast 12 to 24 hour dispatch wins repeat industrial orders.
Best Fit Devices and Applications
- Packaging machines with many synchronized axes.
- Printing presses and web handling lines.
- Textile machines that need fast torque response.
- Palletizers and pick-and-place gantries.
- Winders and unwinders with shared DC bus.
- Material handling conveyors and sorting systems.
- Machine tools with 400 V class asynchronous motors.
- Any cabinet already running Lenze 9400 HighLine modules.
FAQ
- Q: Can I use this module with a synchronous servo motor?
- A: It is specified for 4-pole asynchronous motors in the 400 V class. Check motor data before you buy.
- Q: What is the maximum DC-bus voltage?
- A: The range is 260 V to 775 V DC. Stay inside it at all times.
- Q: How do I connect a laptop for setup?
- A: Use the USB diagnostic port with the E94AZCUS adapter. The Lenze tool finds the drive quickly.
- Q: Does it support EtherCAT or PROFINET out of the box?
- A: No. CANopen is on board. Add an E94AYC module for other protocols.
- Q: What happens above +45 °C cabinet temperature?
- A: Derate rated output current by 2.5 % per °C. Ignoring this shortens module life.
- Q: How fast do you ship?
- A: We dispatch in 12 to 24 hours on business days via FedEx, UPS or DHL.
- Q: Is a warranty included?
- A: Yes, 12 months cover material and workmanship.
- Q: From experience, what fails first on these modules?
- A: Cooling fans and dirty filters. Clean filters monthly and replace fans early.
- Q: Any tip before I swap a module between machines?
- A: Match firmware and parameter sets first. Mismatches cause most startup faults.
- Q: How do I choose the right variant?
- A: Match rated current to motor current, then confirm DC-bus voltage and needed protocol slots.
- Q: Can I parallel two modules on one motor?
- A: No. Use one module per motor and size it for the load.
Buying Guide
- Start with motor current, not just kW rating.
- Confirm the DC-bus voltage in your existing cabinet.
- List the protocols you need today and next year.
- Count free E94AYC slots in your design.
- Check cabinet air temperature and plan derating.
- Check site altitude for highland installations.
- Order the E94AZCUS adapter if you lack one.
- Ask us for a firmware check before shipping. It avoids surprises.
- Need help? Email sales@powergearx.com or message +86 18030005825.
Contact
- Email: sales@powergearx.com
- WhatsApp: +86 18030005825
- Response time: within one business day.
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
















There are no reviews yet.