E84AYCPMV-S PROFIBUS Communication Module for Lenze Inverter Drives 8400

The E84AYCPMV-S connects Lenze Inverter Drives 8400 to a PROFIBUS network. It fits the MCI slot. It supports StateLine C, HighLine C and TopLine C drives. The module handles fast process data and clear drive control. It suits demanding factory automation.

Key Benefits

  • Simple integration. Plugs into one MCI slot. No extra power supply needed.
  • Fast bus speed. Auto-detects baud rates from 9.6 kbit/s to 12000 kbit/s.
  • Flexible data use. Supports 1 to 16 process data words.
  • Wide network reach. Up to 31 slaves per segment without repeater. Up to 125 with repeaters.
  • Coated version. The V suffix marks the coated variant for tougher sites.
  • Proven protocol. Works with PROFIBUS DP-V0 (DRIVECOM) and DP-V1 (PROFIdrive).

Technical Specifications

  • Brand: Lenze
  • Model: E84AYCPMV-S
  • Series: Inverter Drives 8400
  • Module type: PROFIBUS communication option module, MCI slot
  • Protocol: PROFIBUS DP-V0 (DRIVECOM) and DP-V1 (PROFIdrive), PROFIdrive V3
  • Ports: 1 x 9-pin Sub-D connector
  • Baud rate: 9.6 kbit/s to 12000 kbit/s, automatic detection
  • Medium: RS 485
  • Node type: Slave
  • Topology: Line or tree with repeater; line without repeater
  • Process data words: 1 to 16 PCD, 16-bit each
  • Bus nodes: Max. 31 slaves per segment without repeater; max. 125 with repeaters
  • Max. cable length: 1200 m per bus segment, depends on baud rate and cable type
  • Address setting: DIP switch, electrically isolated from the bus
  • Free slots on drive: 1 MCI slot
  • Supply voltage: Not applicable, powered by the host drive via the MCI slot
  • Operating temperature: -10 °C to +55 °C (3K3, EN 60721-3-3)
  • Storage temperature: -25 °C to +60 °C (1K3, EN 60721-3-1)
  • Relative humidity: Non-condensing; no specific %RH value published in the official manual
  • Protection rating: IP20 (EN 60529)
  • Insulation voltage: 50 V to reference earth/PE
  • Dimensions (H x W x D): 50 mm x 67 mm x 50 mm
  • Weight: Not published by the manufacturer
  • Lifecycle: Mature. Active in the official Lenze 8400 catalogue as of 2026-10. No replacement listed.

Order Code Structure

  • E84AYCPMV-S
    • E84AYCPM — core PROFIBUS module family
      • V — coated version
      • S — standard version (E84AYCPMS)
  • Protocol and interface data stay the same for both variants.

Installation Guide

  • Power off the Lenze 8400 drive first.
  • Insert the module into the free MCI slot.
  • Set the bus address with the DIP switch.
  • Connect the 9-pin Sub-D plug to the PROFIBUS line.
  • Use a repeater for long runs or many nodes.
  • Check the shield and earth connection.
  • Power on and confirm the bus link.

Setup and Maintenance

  • Address setup takes seconds with the DIP switch.
  • Baud rate detection is automatic. No manual tuning.
  • No battery or wear parts inside the module.
  • Check the Sub-D plug and cable shield at each service.
  • Keep the MCI slot free of dust and moisture.
  • The coated version resists harsh plant air.

Compatibility

  • Fits Lenze Inverter Drives 8400 StateLine C, HighLine C and TopLine C.
  • Uses PROFIBUS DP-V0 with DRIVECOM profiles.
  • Uses PROFIBUS DP-V1 with PROFIdrive profiles.
  • Works with standard PROFIBUS RS 485 networks.
  • Supports line and tree topologies with repeaters.

Approvals and Standards

  • Protection rating IP20 per EN 60529.
  • Climate class 3K3 per EN 60721-3-3 for operation.
  • Climate class 1K3 per EN 60721-3-1 for storage.
  • Designed for PROFIBUS DP and PROFIdrive networks.

Packing List and Warranty

  • 1 x E84AYCPMV-S PROFIBUS module
  • 1 x quick start note
  • 12-month warranty on the module
  • Shipment within 12 to 24 hours after order confirmation
  • Express delivery by FedEx, UPS and DHL

Manager’s Insight

  • This module keeps older 8400 drives on a live PROFIBUS line.
  • It avoids a full drive swap in many upgrade projects.
  • The coated variant cuts downtime in dusty or humid rooms.
  • Stock one spare per line. Swap time is very short.

Expert Review

  • The module does one job well: clean PROFIBUS access for the 8400 family.
  • Auto baud detection removes common setup errors.
  • Up to 16 process words give enough speed for most drive tasks.
  • The 1200 m segment limit fits large plant layouts.
  • Weak point: no published weight, so plan rack space by size.

Best Fit Devices and Applications

  • Lenze 8400 StateLine C, HighLine C and TopLine C drives.
  • Conveyor lines and material handling cells.
  • Packaging and printing machines.
  • Textile and plastic lines with central PLC control.
  • Retrofit projects that keep an existing PROFIBUS network.

FAQ

  • Does this module fit any 8400 drive?
    • It fits drives with a free MCI slot, mainly StateLine C, HighLine C and TopLine C.
  • Do I need a separate power supply?
    • No. The host drive powers the module through the MCI slot.
  • What does the V in the order code mean?
    • V marks the coated version. S marks the standard version.
  • How fast can the bus run?
    • From 9.6 kbit/s up to 12000 kbit/s. The module detects the rate itself.
  • Can I use more than 31 nodes?
    • Yes, with repeaters. The limit rises to 125 nodes.
  • How do I set the address?
    • Use the DIP switch. It is isolated from the bus.
  • Experience tip: my drive shows no bus link. What first?
    • Check the DIP address and the Sub-D plug. Most faults sit there.
  • Experience tip: long cable, weak signal. What helps?
    • Add a repeater and keep the shield earthed at both ends.
  • Buying tip: coated or standard?
    • Pick the coated V version for dust, humidity or washdown areas. Pick S for clean cabinets.
  • Buying tip: how many spares?
    • Keep one spare per production line. Swap time is short.

Buying Guide

  • Confirm your drive series and a free MCI slot first.
  • Match the module to your PLC network: DP-V0 or DP-V1.
  • Choose the coated V version for harsh rooms.
  • Plan repeaters for long cable runs or many nodes.
  • Order a spare to cut line downtime.

Contact Us

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE84AYCPMV-S
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E84AYCPMV-S Lenze Inverter Drives 8400 PROFIBUS DP Communication Card Lenze Inverter Drives”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart