Over 50,000 hot-selling automation module components.

E84AYCPMV Lenze PROFIBUS Module for 8400 Inverter Drives

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: E84AYCPMV

Product details

E84AYCPMV PROFIBUS Communication Option Module for Lenze 8400 Inverter Drives

The E84AYCPMV is a PROFIBUS communication option module from Lenze, part of the Inverter Drives 8400 series. It plugs into the MCI slot of 8400 StateLine C, HighLine C and TopLine C drives. The module connects the drive to a PROFIBUS network. It supports PROFIBUS DP-V0 with DRIVECOM and DP-V1 with PROFIdrive. This gives users a proven path for fast, reliable drive integration in factory automation.

The module suits machine builders and plant operators who need a compact, bus-powered interface. It handles process data exchange without extra cabling. Baud rate detection runs automatically from 9.6 kbit/s to 12 Mbit/s. Up to 16 process data words are available for cyclic communication.

Need stock or a quote? Contact sales@powergearx.com or +86 18030005825 on WhatsApp. Orders ship in 12 to 24 hours via FedEx, UPS or DHL.

Technical Specifications

  • Brand: Lenze
  • Model: E84AYCPMV
  • Series: Inverter Drives 8400
  • Module type: PROFIBUS communication option module, MCI slot
  • Protocol: PROFIBUS DP-V0 (DRIVECOM) / DP-V1 (PROFIdrive)
  • Port: 1 × 9-pin Sub-D connector
  • Baud rate: 9.6 kbit/s to 12000 kbit/s, automatic detection
  • Medium: RS 485
  • Node type: Slave
  • Process data words: 1 to 16, each 16-bit
  • Max bus nodes: 31 slaves per segment without repeater; 125 with repeaters
  • Max cable length per segment: 1200 m, depending on baud rate and cable type
  • Address setting: DIP switch, electrically isolated from the bus
  • Free slots on drive: 1 MCI slot
  • Supply voltage: Not applicable, powered by host drive via MCI slot
  • Operating temperature: -10 °C to +55 °C (3K3, EN 60721-3-3)
  • Storage temperature: -25 °C to +60 °C (1K3, EN 60721-3-1)
  • Relative humidity: Non-condensing; no specific %RH published in official manual
  • Protection rating: IP20 (EN 60529)
  • Insulation voltage to reference earth/PE: 50 V
  • Dimensions (H × W × D): 50 mm × 67 mm × 50 mm
  • Weight: Not published by manufacturer

Order Code Structure

  • E84AYCPMV
    • Coated version
    • Core PROFIBUS interface data identical to the standard version
  • E84AYCPMS
    • Standard version
    • Same protocol and interface performance as the coated version

User input “E84AYCPMV-S” maps to the E84AYCPM family. Both variants share the same PROFIBUS protocol and interface data. Check the suffix before ordering to confirm the coating requirement.

Installation Guide

  • Power down the Lenze 8400 drive before fitting the module.
  • Insert the module into the free MCI slot.
  • Set the PROFIBUS address with the DIP switch.
  • Connect the 9-pin Sub-D port to the PROFIBUS line.
  • Use a repeater for segments above 31 slaves.
  • Respect the 1200 m segment limit at the selected baud rate.
  • Keep the module isolated from the bus when setting the address.

Commissioning and Maintenance

  • The module detects baud rate automatically, which shortens setup time.
  • DIP switch addressing makes node changes quick and tool-free.
  • The module takes power from the drive, so no separate supply is needed.
  • PROFIBUS DP-V1 and PROFIdrive V3 support easy parameter access.
  • Maintenance is minimal; the module has no user-serviceable parts.
  • Check the Sub-D connection during routine cabinet inspections.

Compatibility Notes

  • Fits Lenze 8400 StateLine C drives.
  • Fits Lenze 8400 HighLine C drives.
  • Fits Lenze 8400 TopLine C drives.
  • Works with PROFIBUS DP-V0 and DP-V1 networks.
  • Supports DRIVECOM and PROFIdrive profiles.
  • Uses one MCI slot on the host drive.
  • Not a stand-alone unit; a host drive is required.

Certifications and Compliance

  • Protection rating IP20 under EN 60529.
  • Operating climate class 3K3 under EN 60721-3-3.
  • Storage climate class 1K3 under EN 60721-3-1.
  • Insulation voltage to reference earth/PE: 50 V.
  • Audit status: OFFICIAL_VERIFIED.

Packing List and Warranty

  • 1 × E84AYCPMV PROFIBUS communication option module
  • 12-month warranty
  • Orders ship in 12 to 24 hours
  • Courier options: FedEx, UPS, DHL

Expert Review

The E84AYCPMV is a practical choice for plants that already run PROFIBUS. It brings Lenze 8400 drives onto the bus with little setup effort. Automatic baud rate detection removes a common source of errors. DIP switch addressing keeps node changes simple. The 16 process data words cover most standard drive control and feedback tasks. Engineers who value a stable, well-documented interface will find this module easy to work with. The coated version adds protection in tougher cabinet environments. Contact sales@powergearx.com for help matching the module to your drive variant.

Manager’s Insight

This module stays in the current Lenze portfolio as of 2026-10. There is no replacement listed. That makes it a safe pick for new builds and for spares. Buyers should confirm the drive series and the coating requirement before ordering. The standard and coated variants share the same protocol data, so a quick suffix check avoids returns. Our team ships fast, usually within 12 to 24 hours. Call +86 18030005825 to confirm stock.

Best Fit Applications and Devices

  • Lenze 8400 StateLine C inverter drives
  • Lenze 8400 HighLine C inverter drives
  • Lenze 8400 TopLine C inverter drives
  • Factory automation lines with PROFIBUS DP backbones
  • Conveyor and material handling systems
  • Packaging and labeling machines
  • Pumping and fan control panels
  • Retrofit projects that keep existing PROFIBUS networks

FAQ

Q: Which Lenze drive series accept this module?

A: It fits the 8400 StateLine C, HighLine C and TopLine C drives through the MCI slot.

Q: Does the module need a separate power supply?

A: No. The host drive powers it through the MCI slot.

Q: Can I use it on a DP-V1 network?

A: Yes. It supports PROFIBUS DP-V1 with PROFIdrive V3.

Q: How many process data words does it handle?

A: It supports 1 to 16 process data words, each 16-bit.

Q: What is the top baud rate?

A: The module reaches 12000 kbit/s and detects the rate automatically.

Q: From experience, what should I check first if the drive does not appear on the bus?

A: Check the DIP switch address and the Sub-D connector seating. A wrong address or a loose plug is the usual cause.

Q: Is the coated version worth it?

A: Choose the coated E84AYCPMV when the cabinet sees moisture, dust or corrosive air. For clean cabinets, the standard E84AYCPMS works well.

Q: How should I choose between this module and another option card?

A: Match the card to the network you already run. If your plant uses PROFIBUS, this module keeps wiring and engineering effort low.

Q: Do you ship fast?

A: Yes. We dispatch in 12 to 24 hours via FedEx, UPS or DHL. Email sales@powergearx.com for lead time on larger orders.

Purchasing Guidance

  • Confirm the host drive series is 8400 StateLine C, HighLine C or TopLine C.
  • Decide on the coated E84AYCPMV or the standard E84AYCPMS version.
  • Count your process data needs; stay within 16 words.
  • Plan segment length and repeater use for large networks.
  • Keep one spare module for critical lines.
  • Ask our team for a compatibility check before ordering.

Contact sales@powergearx.com or +86 18030005825 for quotes, stock and shipping options.

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE84AYCPMV
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E84AYCPMV Lenze PROFIBUS Module for 8400 Inverter Drives”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart