Over 50,000 hot-selling automation module components.

E82EV552K2C200 Lenze 8200 Vector Inverter 5.5 kW

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: E82EV552K2C200

Product details

E82EV552K2C200 – Lenze 8200 vector Frequency Inverter for 5.5 kW Motors

The E82EV552K2C200 is a panel-mounted frequency inverter from the Lenze 8200 vector series. It drives a 5.5 kW four-pole asynchronous motor with reliable V/f and vector control. This 2xx design variant comes without an integrated EMC filter. It suits OEM machines, retrofits, and spare-part programs. The unit is a legacy Lenze product. Lenze confirms a migration path to the i950 generation. No drop-in same-order-code replacement exists. For urgent projects, stock is ready for 12–24 hour dispatch via FedEx, UPS, or DHL. Questions? Reach sales@powergearx.com or chat on +86 18030005825.

Why This Inverter Stands Out

  • Proven 8200 vector platform with linear/quadratic V/f, vector control, and sensorless torque control.
  • 22.5 A rated output current at 8 kHz switching frequency for a 5.5 kW motor.
  • 33.8 A max output current for 60 s in periodic load cycles.
  • 1.8 x rated torque overload for 60 s when motor and controller power match.
  • Switching frequency 2/4/8/16 kHz with a noise-optimised setting.
  • Output frequency up to 650 Hz for flexible speed ranges.
  • 230 V class supply from 1/N/PE or 3/PE AC, 180–264 V, 45–65 Hz.
  • Compact panel unit at 240 × 125 × 140 mm and 3.6 kg.
  • IP20 protection, upgradeable to IP41 with push-through mounting.
  • Wide temperature window from -10 to +55 °C with derating above +40 °C.

Technical Specifications

  • Brand: Lenze
  • Model: E82EV552K2C200
  • Series: 8200 vector
  • Module type: Panel-mounted frequency inverter, E design, 2xx variant without integrated EMC filter
  • Rated motor power: 5.5 kW typical, four-pole three-phase asynchronous motor
  • Rated output current: 22.5 A nominal at 8 kHz switching frequency
  • Max output current: 33.8 A for 60 s, periodic load change cycle
  • Motor control: V/f characteristic control (linear/quadratic), vector control, sensorless torque control
  • Switching frequency: 2 / 4 / 8 / 16 kHz, noise-optimised setting
  • Output frequency range: 0 to 650 Hz
  • Overload capability: 1.8 x rated torque for 60 s when rated motor power equals rated controller power
  • Supply voltage: 1/N/PE or 3/PE AC 180–264 V nominal, 230 V class, 45–65 Hz
  • Power loss: 250 W at rated current and 8 kHz
  • Operating temperature: -10 to +55 °C, derated by 2.5 %/°C above +40 °C
  • Storage temperature: -25 to +60 °C
  • Relative humidity: average 85 % RH, no condensation, climatic class 3K3 per EN 50178
  • Protection rating: IP20 per EN 60529; IP41 with push-through, thermally separated mounting
  • Dimensions (H × W × D): 240 × 125 × 140 mm
  • Weight: 3.6 kg
  • Built-in ports: control terminals X3 with digital inputs, analog input/output, relay output K1
  • Onboard fieldbus: none
  • Integrated protocols: none
  • Communication expansion: via plug-in I/O or fieldbus option modules, for example E82ZAFSC010 Standard I/O and E82ZAFAC010 Application I/O
  • Lifecycle status: legacy product, official Lenze previous-products page active, migration path to i950
  • Audit status: OFFICIAL_VERIFIED

Installation Guide

  • Mount the unit vertically on a panel with free airflow above and below.
  • Use push-through mounting to reach IP41 protection when heat separation is needed.
  • Keep the 2xx variant in mind: add an external EMC filter where EMC limits apply.
  • Wire control signals to terminals X3 for digital inputs, analog signals, and relay output K1.
  • Confirm supply class 230 V before power-up: 1/N/PE or 3/PE, 180–264 V.
  • Respect derating above +40 °C at 2.5 %/°C to protect the drive.

Commissioning and Maintenance Convenience

  • Parameter setup follows the familiar 8200 vector structure, which shortens technician training.
  • Select V/f or vector mode to match simple pumps, fans, or higher-torque loads.
  • Set the switching frequency to 2/4/8/16 kHz to balance noise and losses.
  • Use relay output K1 for ready or fault signalling to a controller.
  • Keep the heatsink clear of dust; check fan and airflow at each service interval.
  • Log parameters before replacement to speed up migration to the i950 platform.

Compatibility Notes

  • Designed for a 5.5 kW four-pole asynchronous motor with 22.5 A rated current.
  • Works in 230 V class networks with 1/N/PE or 3/PE supply.
  • Fieldbus and extra I/O come through plug-in options such as E82ZAFSC010 and E82ZAFAC010.
  • No onboard Ethernet or fieldbus; plan network access through option modules.
  • No drop-in same-order-code successor; Lenze points to the i950 with PROFIBUS module or L_ICIP library for emulation.
  • Check motor insulation and cable length when output frequency rises toward 650 Hz.

Certification Information

  • Protection rating tested to EN 60529: IP20 standard, IP41 with push-through mounting.
  • Climatic class 3K3 per EN 50178 for humidity and environmental robustness.
  • Legacy status is confirmed on Lenze official previous-products documentation.
  • Migration guidance is documented in Lenze AKB articles 321231 and 316137.

Packing List

  • 1 × Lenze E82EV552K2C200 frequency inverter
  • 1 × terminal and wiring documentation set
  • 1 × protective packaging for transit
  • Note: option modules such as E82ZAFSC010 and E82ZAFAC010 are not included unless ordered.

Warranty and Shipping

  • 12-month warranty covers manufacturing defects under normal use.
  • 12–24 hour dispatch for stocked units after order confirmation.
  • Express delivery by FedEx, UPS, or DHL with tracking.
  • Order help: sales@powergearx.com or +86 18030005825 on WhatsApp.

Manager’s Insight

  • This drive is a smart choice for plants that already run 8200 vector machines and need fast spares.
  • Buyers should budget for an external EMC filter on the 2xx variant in sensitive environments.
  • For new designs, compare the i950 migration path early to avoid long-term support gaps.
  • Stocking one or two units protects uptime on 5.5 kW process equipment.

Expert Review

  • The E82EV552K2C200 keeps the practical strengths of the 8200 vector family: clear terminals, proven control modes, and easy service.
  • Its 22.5 A rating and 1.8 x torque overload suit mixers, conveyors, and pumps with moderate starting loads.
  • The lack of onboard fieldbus is the main limit; plan a plug-in option from day one.
  • As a legacy item, it rewards buyers who value continuity over new-platform features.

Best-Fit Equipment and Applications

  • Conveyors and material handling lines with 5.5 kW asynchronous motors.
  • Pumps and fans using linear or quadratic V/f control.
  • Mixers and agitators that need sensorless torque control.
  • OEM machines already built around the Lenze 8200 vector platform.
  • Retrofit and spare-part programs for legacy production cells.
  • Panel builders needing a compact IP20 drive with optional IP41 mounting.

FAQ

  • Q: Is this inverter new or used?
    A: It is offered as a legacy Lenze unit. Confirm condition and test reports with the sales team before ordering.
  • Q: Can I use it with a 5.5 kW motor?
    A: Yes. The 22.5 A rated current matches a typical four-pole 5.5 kW asynchronous motor.
  • Q: Does it include an EMC filter?
    A: No. This is the 2xx variant without an integrated EMC filter. Add an external filter where needed.
  • Q: How do I connect to a fieldbus?
    A: Use a plug-in option module. There is no onboard fieldbus or Ethernet port.
  • Q: What is the overload capacity?
    A: 1.8 x rated torque for 60 s when motor and controller power match, plus 33.8 A max current for 60 s.
  • Q: Can I replace a failed 8200 vector with an i950?
    A: Yes, Lenze confirms an i950 migration path with PROFIBUS module or L_ICIP library, but not a drop-in same-order-code swap.
  • Q: How fast do you ship?
    A: Stocked units leave in 12–24 hours by FedEx, UPS, or DHL.
  • Q: What does the warranty cover?
    A: A 12-month warranty covers manufacturing defects under normal use.
  • Q: How do I choose between V/f and vector control?
    A: Use V/f for simple pumps and fans. Use vector control for higher starting torque or tighter speed control.
  • Q: What should I check before buying a legacy drive?
    A: Confirm motor current, supply class, EMC needs, and the long-term migration plan. Ask for a test record and compare the i950 path for new builds.
  • Q: Do you support urgent plant shutdowns?
    A: Yes. Contact sales@powergearx.com or +86 18030005825 for priority handling.

Buying Guide

  • Match the drive to motor current first: 22.5 A rated and 33.8 A peak for 60 s.
  • Check supply: 230 V class, 1/N/PE or 3/PE, 180–264 V, 45–65 Hz.
  • Decide on EMC early; the 2xx variant needs an external filter in noisy or regulated sites.
  • Plan communication with a plug-in module such as E82ZAFSC010 or E82ZAFAC010.
  • For new machines, compare total cost against the i950 migration path.
  • For urgent repairs, confirm stock and dispatch time before purchase.

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE82EV552K2C200
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E82EV552K2C200 Lenze 8200 Vector Inverter 5.5 kW”

Your email address will not be published. Required fields are marked *

Back to Top