Product details
E82EV552K2C200 – Lenze 8200 vector Frequency Inverter for 5.5 kW Motors
The E82EV552K2C200 is a panel-mounted frequency inverter from the Lenze 8200 vector series. It drives a 5.5 kW four-pole asynchronous motor with reliable V/f and vector control. This 2xx design variant comes without an integrated EMC filter. It suits OEM machines, retrofits, and spare-part programs. The unit is a legacy Lenze product. Lenze confirms a migration path to the i950 generation. No drop-in same-order-code replacement exists. For urgent projects, stock is ready for 12–24 hour dispatch via FedEx, UPS, or DHL. Questions? Reach sales@powergearx.com or chat on +86 18030005825.
Why This Inverter Stands Out
- Proven 8200 vector platform with linear/quadratic V/f, vector control, and sensorless torque control.
- 22.5 A rated output current at 8 kHz switching frequency for a 5.5 kW motor.
- 33.8 A max output current for 60 s in periodic load cycles.
- 1.8 x rated torque overload for 60 s when motor and controller power match.
- Switching frequency 2/4/8/16 kHz with a noise-optimised setting.
- Output frequency up to 650 Hz for flexible speed ranges.
- 230 V class supply from 1/N/PE or 3/PE AC, 180–264 V, 45–65 Hz.
- Compact panel unit at 240 × 125 × 140 mm and 3.6 kg.
- IP20 protection, upgradeable to IP41 with push-through mounting.
- Wide temperature window from -10 to +55 °C with derating above +40 °C.
Technical Specifications
- Brand: Lenze
- Model: E82EV552K2C200
- Series: 8200 vector
- Module type: Panel-mounted frequency inverter, E design, 2xx variant without integrated EMC filter
- Rated motor power: 5.5 kW typical, four-pole three-phase asynchronous motor
- Rated output current: 22.5 A nominal at 8 kHz switching frequency
- Max output current: 33.8 A for 60 s, periodic load change cycle
- Motor control: V/f characteristic control (linear/quadratic), vector control, sensorless torque control
- Switching frequency: 2 / 4 / 8 / 16 kHz, noise-optimised setting
- Output frequency range: 0 to 650 Hz
- Overload capability: 1.8 x rated torque for 60 s when rated motor power equals rated controller power
- Supply voltage: 1/N/PE or 3/PE AC 180–264 V nominal, 230 V class, 45–65 Hz
- Power loss: 250 W at rated current and 8 kHz
- Operating temperature: -10 to +55 °C, derated by 2.5 %/°C above +40 °C
- Storage temperature: -25 to +60 °C
- Relative humidity: average 85 % RH, no condensation, climatic class 3K3 per EN 50178
- Protection rating: IP20 per EN 60529; IP41 with push-through, thermally separated mounting
- Dimensions (H × W × D): 240 × 125 × 140 mm
- Weight: 3.6 kg
- Built-in ports: control terminals X3 with digital inputs, analog input/output, relay output K1
- Onboard fieldbus: none
- Integrated protocols: none
- Communication expansion: via plug-in I/O or fieldbus option modules, for example E82ZAFSC010 Standard I/O and E82ZAFAC010 Application I/O
- Lifecycle status: legacy product, official Lenze previous-products page active, migration path to i950
- Audit status: OFFICIAL_VERIFIED
Installation Guide
- Mount the unit vertically on a panel with free airflow above and below.
- Use push-through mounting to reach IP41 protection when heat separation is needed.
- Keep the 2xx variant in mind: add an external EMC filter where EMC limits apply.
- Wire control signals to terminals X3 for digital inputs, analog signals, and relay output K1.
- Confirm supply class 230 V before power-up: 1/N/PE or 3/PE, 180–264 V.
- Respect derating above +40 °C at 2.5 %/°C to protect the drive.
Commissioning and Maintenance Convenience
- Parameter setup follows the familiar 8200 vector structure, which shortens technician training.
- Select V/f or vector mode to match simple pumps, fans, or higher-torque loads.
- Set the switching frequency to 2/4/8/16 kHz to balance noise and losses.
- Use relay output K1 for ready or fault signalling to a controller.
- Keep the heatsink clear of dust; check fan and airflow at each service interval.
- Log parameters before replacement to speed up migration to the i950 platform.
Compatibility Notes
- Designed for a 5.5 kW four-pole asynchronous motor with 22.5 A rated current.
- Works in 230 V class networks with 1/N/PE or 3/PE supply.
- Fieldbus and extra I/O come through plug-in options such as E82ZAFSC010 and E82ZAFAC010.
- No onboard Ethernet or fieldbus; plan network access through option modules.
- No drop-in same-order-code successor; Lenze points to the i950 with PROFIBUS module or L_ICIP library for emulation.
- Check motor insulation and cable length when output frequency rises toward 650 Hz.
Certification Information
- Protection rating tested to EN 60529: IP20 standard, IP41 with push-through mounting.
- Climatic class 3K3 per EN 50178 for humidity and environmental robustness.
- Legacy status is confirmed on Lenze official previous-products documentation.
- Migration guidance is documented in Lenze AKB articles 321231 and 316137.
Packing List
- 1 × Lenze E82EV552K2C200 frequency inverter
- 1 × terminal and wiring documentation set
- 1 × protective packaging for transit
- Note: option modules such as E82ZAFSC010 and E82ZAFAC010 are not included unless ordered.
Warranty and Shipping
- 12-month warranty covers manufacturing defects under normal use.
- 12–24 hour dispatch for stocked units after order confirmation.
- Express delivery by FedEx, UPS, or DHL with tracking.
- Order help: sales@powergearx.com or +86 18030005825 on WhatsApp.
Manager’s Insight
- This drive is a smart choice for plants that already run 8200 vector machines and need fast spares.
- Buyers should budget for an external EMC filter on the 2xx variant in sensitive environments.
- For new designs, compare the i950 migration path early to avoid long-term support gaps.
- Stocking one or two units protects uptime on 5.5 kW process equipment.
Expert Review
- The E82EV552K2C200 keeps the practical strengths of the 8200 vector family: clear terminals, proven control modes, and easy service.
- Its 22.5 A rating and 1.8 x torque overload suit mixers, conveyors, and pumps with moderate starting loads.
- The lack of onboard fieldbus is the main limit; plan a plug-in option from day one.
- As a legacy item, it rewards buyers who value continuity over new-platform features.
Best-Fit Equipment and Applications
- Conveyors and material handling lines with 5.5 kW asynchronous motors.
- Pumps and fans using linear or quadratic V/f control.
- Mixers and agitators that need sensorless torque control.
- OEM machines already built around the Lenze 8200 vector platform.
- Retrofit and spare-part programs for legacy production cells.
- Panel builders needing a compact IP20 drive with optional IP41 mounting.
FAQ
- Q: Is this inverter new or used?
A: It is offered as a legacy Lenze unit. Confirm condition and test reports with the sales team before ordering. - Q: Can I use it with a 5.5 kW motor?
A: Yes. The 22.5 A rated current matches a typical four-pole 5.5 kW asynchronous motor. - Q: Does it include an EMC filter?
A: No. This is the 2xx variant without an integrated EMC filter. Add an external filter where needed. - Q: How do I connect to a fieldbus?
A: Use a plug-in option module. There is no onboard fieldbus or Ethernet port. - Q: What is the overload capacity?
A: 1.8 x rated torque for 60 s when motor and controller power match, plus 33.8 A max current for 60 s. - Q: Can I replace a failed 8200 vector with an i950?
A: Yes, Lenze confirms an i950 migration path with PROFIBUS module or L_ICIP library, but not a drop-in same-order-code swap. - Q: How fast do you ship?
A: Stocked units leave in 12–24 hours by FedEx, UPS, or DHL. - Q: What does the warranty cover?
A: A 12-month warranty covers manufacturing defects under normal use. - Q: How do I choose between V/f and vector control?
A: Use V/f for simple pumps and fans. Use vector control for higher starting torque or tighter speed control. - Q: What should I check before buying a legacy drive?
A: Confirm motor current, supply class, EMC needs, and the long-term migration plan. Ask for a test record and compare the i950 path for new builds. - Q: Do you support urgent plant shutdowns?
A: Yes. Contact sales@powergearx.com or +86 18030005825 for priority handling.
Buying Guide
- Match the drive to motor current first: 22.5 A rated and 33.8 A peak for 60 s.
- Check supply: 230 V class, 1/N/PE or 3/PE, 180–264 V, 45–65 Hz.
- Decide on EMC early; the 2xx variant needs an external filter in noisy or regulated sites.
- Plan communication with a plug-in module such as E82ZAFSC010 or E82ZAFAC010.
- For new machines, compare total cost against the i950 migration path.
- For urgent repairs, confirm stock and dispatch time before purchase.
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/














There are no reviews yet.