E82EV402K2C Lenze 8200 Vector Frequency Inverter – 4.0 kW Panel-Mounted Drive
The E82EV402K2C is a Lenze 8200 vector frequency inverter. It is a panel-mounted E-design unit. It runs a 4.0 kW four-pole asynchronous motor. The drive supports V/f control, vector control, and sensorless torque control. It is a proven workhorse for industrial speed control.
Key Technical Data
- Brand: Lenze
- Model: E82EV402K2C
- Series: 8200 vector
- Module type: Panel-mounted frequency inverter (E design)
- Rated motor power: 4.0 kW typical (4-pole three-phase async motor)
- Rated output current: 16.5 A at 8 kHz switching frequency; 19.8 A at 2/4 kHz (increased rating)
- Max output current: 24.8 A for 60 s (periodic load cycle)
- Overload: 1.8 x rated torque for 60 s
- Switching frequency: 2 / 4 / 8 / 16 kHz, noise-optimised
- Output frequency range: 0 to 650 Hz
- Supply voltage: 1/N/PE or 3/PE AC 180 to 264 V (230 V class, 45 to 65 Hz)
- Power loss: 190 W at rated current / 8 kHz
- Operating temperature: -10 to +55 °C (derate 2.5%/°C above +40 °C)
- Storage temperature: -25 to +60 °C
- Humidity: 85 % RH average, no condensation (climatic class 3K3)
- Protection rating: IP20; IP41 with push-through mounting
- Dimensions (H×W×D): 240 × 100 × 140 mm
- Weight: 2.9 kg
Core Performance Information
- Measurement range: 0 to 650 Hz output frequency
- Frequency response: fast torque response via sensorless vector control
- Sensitivity and linearity: stable V/f linear and quadratic curves
- Resolution: fine speed steps across the full output range
- Temperature range: -10 to +55 °C operating
- Environmental tolerance: 3K3 climatic class, 85 % RH
- Interference immunity: built for industrial EMC environments per EN 50178
Communication and Compatibility
- Built-in ports: X3 control terminals with digital inputs, analog input/output, and relay output K1
- Onboard fieldbus: none
- Ethernet: none
- Protocols: no integrated fieldbus protocol
- Expansion: plug-in I/O and fieldbus option modules, e.g. E82ZAFSC010 Standard I/O and E82ZAFAC010 Application I/O
- Migration path: Lenze confirms the i950 emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library (AKB articles 321231/316137)
- Drop-in replacement: none; order codes differ across generations
Installation Guide
- Mount the unit vertically on a panel with clear airflow.
- Keep the heatsink free; use push-through mounting for IP41.
- Wire supply to 1/N/PE or 3/PE AC 180 to 264 V.
- Connect the motor to the output terminals with shielded cable.
- Land control wiring on X3: digital inputs, analog signals, relay K1.
- Derate 2.5 % per °C above +40 °C ambient.
- Follow local EMC rules for cable routing and grounding.
Commissioning and Maintenance
- Set motor data first; the drive auto-tunes key parameters.
- Pick V/f linear, V/f quadratic, or vector mode per load.
- Set switching frequency to balance noise and heat.
- Check fan paths and terminal torque at each service visit.
- Clean heatsink fins in dusty plants.
- No special tools are needed for routine checks.
Certifications and Packaging
- Protection rating IP20 per EN 60529; IP41 with push-through mounting
- Climatic class 3K3 per EN 50178
- Package contents: one E82EV402K2C inverter, mounting and terminal documentation
- Warranty: 12 months
- Dispatch: ships within 12 to 24 hours
- Couriers: FedEx, UPS, DHL
Manager’s Insight
This unit suits plants that still run the 8200 vector family. It is a safe spare-part pick. Stock it before a line stops. The 4.0 kW class covers pumps, fans, and conveyors. Buyers who plan a long upgrade should ask about the i950 path at the same time.
Expert Review
Our engineers rate the E82EV402K2C as a robust, simple drive. Vector control gives good torque at low speed. Terminal-based control keeps wiring clear. The main limit is the missing onboard fieldbus. Plan an option module if your network needs one.
Best Fit Applications
- Pumps and fans with variable flow demand
- Conveyors and material handling lines
- Packaging and textile machines
- Legacy 8200 vector retrofit and spare-part pools
- Panel builders needing a compact 4.0 kW drive
Buying Guide
- Confirm 4.0 kW motor power and 16.5 A rated current first.
- Check your supply: 1/N/PE or 3/PE AC 180 to 264 V.
- List needed I/O; add E82ZAFSC010 or E82ZAFAC010 if short.
- Pick fieldbus modules only if the machine network requires them.
- Order spares early; this series is a previous product.
- Ask us about the i950 migration route for new builds.
FAQ
- Q: Is the E82EV402K2C still supported?
A: Yes. Lenze keeps a previous-products page and an i950 migration path. - Q: Does it have a built-in fieldbus?
A: No. Add a plug-in option module for fieldbus or extra I/O. - Q: What motor does it drive?
A: A 4.0 kW four-pole three-phase asynchronous motor. - Q: Can I swap it for an i950 with the same order code?
A: No. The i950 emulates 8200 vector behaviour, but codes differ. - Q: How fast do you ship?
A: Within 12 to 24 hours by FedEx, UPS, or DHL. - Q: Experience tip — what fails first in the field?
A: Dust on heatsink fins. Clean them at every service. - Q: Experience tip — how do I avoid nuisance trips?
A: Set switching frequency to 4 kHz in hot panels and derate above +40 °C. - Q: Buying tip — spare or upgrade?
A: Buy this unit to keep a running line alive. Choose i950 for new projects.