Product details

ATV930C25N4C Altivar Process ATV930 Drive: Built for Heavy Process Loads

Quick Overview

  • Brand: Schneider Electric
  • Model: ATV930C25N4C
  • Series: Altivar Process ATV930
  • Type: Three-phase variable speed drive
  • Mount: IP00, cabinet only
  • Duty: Dual ND / HD rating

Spec Tree

  • Power
    • Normal Duty: 250 kW (400 HP)
    • Heavy Duty: 200 kW (300 HP)
    • ND overload: 120% for 60 s
    • HD overload: 150% for 60 s
  • Supply
    • Voltage: 380 to 480 V, three-phase
    • Tolerance: -15% / +10%
    • Line frequency: 50 / 60 Hz
  • Output
    • Frequency band: 0.1 to 599 Hz
    • Switching: 2.5 kHz nominal
    • ND current: 481 A continuous
    • ND boost: 577 A for 60 s
    • HD current: 387 A continuous
    • HD boost: 581 A for 60 s
  • Input current
    • ND: 451 A at 380 V
    • ND: 366 A at 480 V
    • HD: 365 A at 380 V
    • HD: 301 A at 480 V
  • Power quality
    • ND apparent power: 279 kVA at 380 V
    • HD apparent power: 229 kVA at 380 V
    • SCCR: 50 kA max
    • EMC filter: C3 built in

Control and Motor Tree

  • Motor types
    • Async induction motor
    • Synchronous PM motor
    • Synchronous reluctance motor
  • Control modes
    • Open loop, sensorless vector
    • Closed loop with encoder
    • Constant torque and variable torque
  • Safety
    • 1 STO function
    • SIL3, Cat. PL e
    • 2 safety inputs
  • Braking
    • No built-in chopper
    • External unit for C11 and above

I/O Tree

  • Analog in
    • 3 ports total
    • 2 x 0 to 10 V or 0/4 to 20 mA
    • Probe input: PTC, PT100, PT1000, KTY84
    • 1 x 0 to ±10 V
  • Digital in
    • 8 ports, 24 V DC
    • Positive or negative logic
  • Outputs
    • 1 digital, pulse train ready
    • 2 analog, V or mA
    • 3 relay: 1 NO/NC plus 2 NO
  • Expansion
    • Up to 3 extra I/O modules

Network Tree

  • Built-in
    • 1 Ethernet dual-port switch, RJ45
    • 1 Modbus serial port, RJ45
    • EtherNet/IP and Modbus TCP
    • Modbus RTU
  • Option slot
    • PROFINET
    • PROFIBUS DP V1
    • CANopen
    • DeviceNet
    • EtherCAT
    • POWERLINK
  • Security
    • Achilles Level 2

Environment Tree

  • Running conditions
    • Ambient: 0 to +40 C
    • Derate: +40 to +50 C
    • Humidity: 5 to 95%, no condensation
    • Class: 3C3 / 3S3 / 3M3
  • Altitude
    • 0 to 1000 m: full load
    • 1000 to 3000 m: -1% current per 100 m
  • Storage
    • -40 to +70 C

Physical Tree

  • Size
    • Height: 1195 mm
    • Width: 598 mm
    • Depth: 380 mm
    • Weight: 203 kg
  • Thermal
    • Loss ND: 5983 W
    • Loss HD: 4493 W
    • Air flow: 1260 m3/h
  • Fixing
    • Busbar torque: 41 N·m, M10
    • Clearance: 200 mm top
    • Clearance: 150 mm bottom
    • Clearance: 10 mm front

Where It Fits

  • Water and waste
    • Booster pumps
    • Sewage pumps
    • Aeration blowers
  • Process plant
    • Compressors
    • Mixers and agitators
    • Centrifuges
  • Material handling
    • Long conveyors
    • Crushers
    • Bucket elevators
  • HVAC and energy
    • Large fans
    • Chillers
    • District heating pumps

Certificates

  • UL 508C
  • UL 61800-5-1
  • EN/IEC 61800-3, C2 / C3
  • EN/IEC 61800-5-1
  • IEC 61508
  • ISO 13849-1
  • Achilles Level 2
  • REACH
  • SEMI F47-0706

In the Box

  • ATV930C25N4C drive, IP00
  • Manual NHA80932
  • Safety sheet
  • M10 busbar hardware
  • Sold apart: brake unit, line reactor, IP21 kit

FAQ

  • Q: Will this unit run a 250 kW motor at full torque all day?
    A: Yes, in Normal Duty. For constant torque duty, treat it as a 200 kW drive. Always match the motor curve to the chosen duty.
  • Q: Can I skip the line reactor on a weak grid?
    A: Not wise. A weak supply brings voltage dips and harmonics. Fit the reactor to protect the DC bus and the input rectifier.
  • Q: What happens if I exceed 50 C inside the panel?
    A: The drive derates above 40 C. Beyond 50 C, it may trip on over-temperature. Add forced cooling or split the load.
  • Q: Is encoder feedback worth the extra cable?
    A: It depends on the load. Hoists and positioning axes gain real value. Plain pumps and fans usually run fine in sensorless mode.
  • Q: What is the usual mistake on long motor cables?
    A: Ignoring cable length limits. Long runs add voltage spikes at the motor terminals. Use a dv/dt filter or a shorter route.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV930C25N4C Schneider Electric Altivar Process VSD 250 kW”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart