Product details
ATV930C25N4C Altivar Process ATV930 Drive: Built for Heavy Process Loads
Quick Overview
- Brand: Schneider Electric
- Model: ATV930C25N4C
- Series: Altivar Process ATV930
- Type: Three-phase variable speed drive
- Mount: IP00, cabinet only
- Duty: Dual ND / HD rating
Spec Tree
- Power
- Normal Duty: 250 kW (400 HP)
- Heavy Duty: 200 kW (300 HP)
- ND overload: 120% for 60 s
- HD overload: 150% for 60 s
- Supply
- Voltage: 380 to 480 V, three-phase
- Tolerance: -15% / +10%
- Line frequency: 50 / 60 Hz
- Output
- Frequency band: 0.1 to 599 Hz
- Switching: 2.5 kHz nominal
- ND current: 481 A continuous
- ND boost: 577 A for 60 s
- HD current: 387 A continuous
- HD boost: 581 A for 60 s
- Input current
- ND: 451 A at 380 V
- ND: 366 A at 480 V
- HD: 365 A at 380 V
- HD: 301 A at 480 V
- Power quality
- ND apparent power: 279 kVA at 380 V
- HD apparent power: 229 kVA at 380 V
- SCCR: 50 kA max
- EMC filter: C3 built in
Control and Motor Tree
- Motor types
- Async induction motor
- Synchronous PM motor
- Synchronous reluctance motor
- Control modes
- Open loop, sensorless vector
- Closed loop with encoder
- Constant torque and variable torque
- Safety
- 1 STO function
- SIL3, Cat. PL e
- 2 safety inputs
- Braking
- No built-in chopper
- External unit for C11 and above
I/O Tree
- Analog in
- 3 ports total
- 2 x 0 to 10 V or 0/4 to 20 mA
- Probe input: PTC, PT100, PT1000, KTY84
- 1 x 0 to ±10 V
- Digital in
- 8 ports, 24 V DC
- Positive or negative logic
- Outputs
- 1 digital, pulse train ready
- 2 analog, V or mA
- 3 relay: 1 NO/NC plus 2 NO
- Expansion
- Up to 3 extra I/O modules
Network Tree
- Built-in
- 1 Ethernet dual-port switch, RJ45
- 1 Modbus serial port, RJ45
- EtherNet/IP and Modbus TCP
- Modbus RTU
- Option slot
- PROFINET
- PROFIBUS DP V1
- CANopen
- DeviceNet
- EtherCAT
- POWERLINK
- Security
- Achilles Level 2
Environment Tree
- Running conditions
- Ambient: 0 to +40 C
- Derate: +40 to +50 C
- Humidity: 5 to 95%, no condensation
- Class: 3C3 / 3S3 / 3M3
- Altitude
- 0 to 1000 m: full load
- 1000 to 3000 m: -1% current per 100 m
- Storage
- -40 to +70 C
Physical Tree
- Size
- Height: 1195 mm
- Width: 598 mm
- Depth: 380 mm
- Weight: 203 kg
- Thermal
- Loss ND: 5983 W
- Loss HD: 4493 W
- Air flow: 1260 m3/h
- Fixing
- Busbar torque: 41 N·m, M10
- Clearance: 200 mm top
- Clearance: 150 mm bottom
- Clearance: 10 mm front
Where It Fits
- Water and waste
- Booster pumps
- Sewage pumps
- Aeration blowers
- Process plant
- Compressors
- Mixers and agitators
- Centrifuges
- Material handling
- Long conveyors
- Crushers
- Bucket elevators
- HVAC and energy
- Large fans
- Chillers
- District heating pumps
Certificates
- UL 508C
- UL 61800-5-1
- EN/IEC 61800-3, C2 / C3
- EN/IEC 61800-5-1
- IEC 61508
- ISO 13849-1
- Achilles Level 2
- REACH
- SEMI F47-0706
In the Box
- ATV930C25N4C drive, IP00
- Manual NHA80932
- Safety sheet
- M10 busbar hardware
- Sold apart: brake unit, line reactor, IP21 kit
FAQ
- Q: Will this unit run a 250 kW motor at full torque all day?
A: Yes, in Normal Duty. For constant torque duty, treat it as a 200 kW drive. Always match the motor curve to the chosen duty. - Q: Can I skip the line reactor on a weak grid?
A: Not wise. A weak supply brings voltage dips and harmonics. Fit the reactor to protect the DC bus and the input rectifier. - Q: What happens if I exceed 50 C inside the panel?
A: The drive derates above 40 C. Beyond 50 C, it may trip on over-temperature. Add forced cooling or split the load. - Q: Is encoder feedback worth the extra cable?
A: It depends on the load. Hoists and positioning axes gain real value. Plain pumps and fans usually run fine in sensorless mode. - Q: What is the usual mistake on long motor cables?
A: Ignoring cable length limits. Long runs add voltage spikes at the motor terminals. Use a dv/dt filter or a shorter route.















There are no reviews yet.