Product details
Product Overview
- Model ATV930C22N4C is a high-performance variable speed drive from Schneider Electric.
- This model belongs to the Altivar Process ATV930 series, which is built for demanding industrial applications.
- In addition, it is a three-phase drive for 380…480 V supplies, and it is ideal for cabinet mounting with IP00 protection.
- Moreover, the dual rating design supports both Normal Duty (ND) and Heavy Duty (HD) motor control.
- However, it requires an external braking unit for C11 frame size and above.
Technical Specifications
- Brand: Schneider Electric
- Model: ATV930C22N4C
- Series: Altivar Process ATV930
- Motor Power (ND): 220 kW (350 HP), and it allows 120% overload for 60 s.
- Motor Power (HD): 160 kW (250 HP), and it allows 150% overload for 60 s.
- Output Frequency: 0.1…599 Hz.
- Switching Frequency: 2.5 kHz nominal, with automatic derating above this value.
- Motor Control: It supports asynchronous, PM synchronous, and synchronous reluctance motors.
- Control Modes: Open-loop sensorless flux vector and closed-loop with encoder are both available.
- Safety: The integrated STO function is certified to SIL3 / Cat. PL e.
- Analog Inputs: There are 3 total; 2 are configurable for 0…10 V or 0/4-20 mA, and 1 is configurable for 0…±10 V.
- Digital Inputs: 8 inputs, 24 V DC, with positive or negative logic.
- Digital Output: 1 assignable output, which is configurable as Pulse Train Output.
- Analog Outputs: 2 outputs, and each is configurable for 0…10 V or 0/4-20 mA.
- Relay Outputs: 3 outputs in total (1 NO/NC + 2 NO).
- Safety Inputs: 2 dedicated inputs for the STO function.
- Communication Ports: 1 Ethernet dual-port switch (RJ45) and 1 Modbus serial port (RJ45).
- Protocols: EtherNet/IP, Modbus TCP, and Modbus RTU/TCP are supported.
- Expansion Slot: 1 slot for PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT, or POWERLINK.
- Supply Voltage: 380…480 V three-phase (-15%/+10%), 50/60 Hz.
- ND Input Current: 397 A at 380 V, and 324 A at 480 V.
- ND Output Current: 427 A maximum continuous, and 512 A transient for 60 s.
- HD Input Current: 296 A at 380 V, and 246 A at 480 V.
- HD Output Current: 302 A maximum continuous, and 453 A transient for 60 s.
- SCCR: 50 kA maximum.
- EMC Filter: Category C3 integrated.
- Operating Temperature: 0 to +40 °C standard, and derating applies up to 50 °C.
- Storage Temperature: -40 to +70 °C.
- Relative Humidity: 5 to 95% non-condensing.
- Altitude: Up to 1000 m without derating; above this, derate 1% per 100 m.
- Protection Rating: IP00 for cabinet mounting, and an IP21/UL Type 1 kit is available.
- Power Dissipation: 5214 W (ND) or 3735 W (HD) at nominal load.
- Required Air Flow: 860 m³/h minimum.
- Dimensions (H×W×D): 1195 x 440 x 380 mm.
- Weight: 172.000 kg (as printed in catalog).
- Terminal Torque: 41 N·m (360 lbf·in) for M10 busbars.
- Installation Clearance: 200 mm above, 150 mm below, and 10 mm front.
Installation Guide
- First, mount the drive inside an electrical cabinet with IP00 protection.
- Then, use the conformity kit for IP21/UL Type 1 wall mounting if needed.
- Also, maintain 200 mm clearance above and 150 mm below the drive.
- In addition, keep 10 mm free space in front for proper airflow.
- Therefore, ensure minimum air flow of 860 m³/h for cooling.
- Moreover, tighten M10 supply and output busbars to 41 N·m.
- Finally, connect the external braking unit if the application requires braking.
- For safety, use the integrated STO inputs for safe torque off functionality.
Commissioning and Maintenance
- To start, use the built-in Modbus serial port or Ethernet for quick setup.
- Then, use the dual-port Ethernet switch for daisy-chain network topology.
- Also, configure analog and digital I/O via the keypad or software tools.
- In addition, monitor drive status through the integrated communication ports.
- Moreover, check cooling fan and air filters regularly to maintain airflow.
- Therefore, verify terminal torque during routine maintenance.
- Finally, update firmware through the Ethernet port for the latest features.
Compatibility Notes
- The drive works with asynchronous motors, PM synchronous motors, and synchronous reluctance motors.
- In addition, it supports open-loop and closed-loop vector control.
- Moreover, it accepts PTC, PT100, PT1000, and KTY84 probe inputs for motor temperature monitoring.
- For fieldbus integration, modules are available for PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT, and POWERLINK.
- Also, it integrates with EtherNet/IP and Modbus TCP networks.
- However, an external braking unit is required for C11 frame and above.
Certifications
- The drive is UL 508C and UL 61800-5-1 certified.
- Also, it complies with EN/IEC 61800-3 (category C2/C3).
- Moreover, it meets EN/IEC 61800-5-1 requirements.
- For functional safety, it follows IEC 61508 and IEC 13849-1.
- In addition, it holds Achilles Level 2 cybersecurity certification.
- Furthermore, it is REACH and SEMI F47-0706 compliant.
- Finally, it meets environmental class 3C3 / 3S3 / 3M3 per IEC 60721-3-3 (except frame size 7).
Package Contents
- 1 x ATV930C22N4C variable speed drive.
- In addition, 1 x Installation manual (NHA80932).
- Also, 1 x Safety function terminal block.
- Moreover, 1 x EMC filter (integrated).
- However, the conformity kit is sold separately for IP21/UL Type 1 mounting.
- Similarly, the external braking unit is sold separately for C11 frame and above.
FAQ
- What is the difference between ND and HD ratings?
- ND (Normal Duty) provides 120% overload for 60 seconds for standard loads.
- In contrast, HD (Heavy Duty) offers 150% overload for 60 seconds for high-demand applications.
- Can I mount this drive directly on a wall?
- The drive is IP00 rated for cabinet mounting only.
- However, an optional conformity kit enables IP21/UL Type 1 wall mounting.
- What type of braking is available?
- This model does not have a built-in brake chopper.
- Therefore, an external braking unit is required for dynamic braking applications.
- How do I connect the drive to my network?
- First, use the built-in dual-port Ethernet switch for EtherNet/IP or Modbus TCP.
- Also, use the Modbus serial port for RTU communication.
- Finally, add a fieldbus module for PROFINET, EtherCAT, or other protocols.
- What is the maximum ambient temperature?
- The drive operates up to 40 °C without derating.
- However, between 40 °C and 50 °C, derate the output current according to the manual.
- Does the drive support motor temperature sensors?
- Yes, analog inputs accept PTC, PT100, PT1000, and KTY84 probes.
- This helps protect the motor from overheating.
- What is the weight of this drive?
- The catalog lists 172.000 kg (319.195 lb).
- However, the pound figure appears to be a catalog misprint, so treat the kilogram value as reliable.
- Can I use this drive with a synchronous motor?
- Yes, it supports PM synchronous motors and synchronous reluctance motors.
- In addition, both open-loop and closed-loop vector control are available.
- What is the STO function?
- STO stands for Safe Torque Off, a safety function that prevents motor torque generation.
- Moreover, it is certified to SIL3 / Cat. PL e for high safety integrity.
- How many I/O expansion modules can I add?
- You can add up to 3 additional I/O modules.
- Therefore, this provides flexible adaptation to different control requirements.
















There are no reviews yet.