Over 50,000 hot-selling automation module components.

ATV610C11N4Z Schneider Easy Altivar 610 110 kW Pump Fan Drive

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: ATV610C11N4Z
Brands:

Product details

ATV610C11N4Z: Big Power for Pumps and Fans

ATV610C11N4Z is a Schneider Electric drive for large pump and fan jobs. It runs at 110 kW (150 HP) normal duty on 380…460 V three-phase. A heavy duty rating of 90 kW is also available. The drive has an integrated C3 EMC filter. It comes without a display to keep the price low. You can add the VW3A1113 keypad later. The case is IP00. Add the IP21 kit for touch safety. Also, a built-in DC choke cuts harmonics. However, THDi under 10% needs the optional passive filter. Therefore, plan that part if power quality matters. The fan is field-replaceable in under 5 minutes.

Technical Specifications

  • Brand: Schneider Electric
  • Model: ATV610C11N4Z
  • Series: Easy Altivar 610
  • Type: Variable speed drive (AC frequency inverter) for pumps and fans
  • Motor Power: 110 kW (150 HP) normal duty; 90 kW (125 HP) heavy duty
  • Supply: 380…460 V three-phase, 50/60 Hz
  • Input Current: 201 A at 380 V; 175.7 A at 460 V (ND)
  • Output Current: 211 A continuous (ND); 173 A (HD)
  • Transient Current: 232 A for 60 s (ND); 260 A (HD)
  • Apparent Power: 140 kVA at 460 V
  • SCCR: 50 kA
  • Output Frequency: 0.1…500 Hz
  • Switching Frequency: 1…8 kHz adjustable; 2.5 kHz nominal (derate above)
  • Control Modes: U/f STD, U/f 5-point, U/f quadratic, open-loop PMSM, reluctance motor
  • Motor Cable: 150 m shielded / 200 m unshielded; output filter advised above 50 m
  • Analog Inputs: 3, configurable 0…10 V / 0…20 mA
  • Digital Inputs: 6, 24 V DC (2 can be pulse inputs)
  • Analog Outputs: 2, configurable 0…10 V / 0…20 mA
  • Relay Outputs: 3, configurable logic
  • I/O Expansion: Slot A for VW3A3203 (extended I/O) or VW3A3204 (extended relay)
  • Ports: 2 RJ45 Modbus serial-link ports (field network + HMI)
  • Protocol: Modbus RTU over RS485
  • Expansion: Slot A for PROFIBUS DP V1 module VW3A3607
  • Braking: external resistor terminals PA/+, PB
  • Power Loss: 2290 W at nominal current (enclosed cabinet)
  • Operating Temperature: -15…+45 °C no derating; up to +60 °C with derating
  • Storage Temperature: -40…+70 °C
  • Humidity: 5…95%, no condensation
  • Altitude: 1000 m no derating; 1000…3000 m with derating
  • Protection: IP00 (IP21 kit optional)
  • Coating: conformal coated boards
  • Size (H×W×D): 850 x 300 x 375 mm (frame 6)
  • Weight: 85.445 kg (188.4 lb)
  • Terminal Torque: 27 N·m (frame 6)
  • Clearance: top 250 mm, bottom 250 mm, front 100 mm; mount vertical ±10°

Installation Guide

  • Mount the drive vertical. Tilt no more than ±10°.
  • Keep 250 mm free at top and bottom. Keep 100 mm in front. This keeps the fan working well.
  • Tighten power terminals to 27 N·m.
  • Use shielded cable up to 150 m. Add an output filter above 50 m.
  • Fit the IP21 kit if people can touch the drive.
  • Keep relay supply at OVC II. Use an isolation transformer if not.
  • Add the external resistor on PA/+ and PB for braking.

Setup and Service

  • Set switching frequency from 1 to 8 kHz. Nominal is 2.5 kHz.
  • Derate power above 2.5 kHz.
  • Derate load above 45 °C or 1000 m altitude.
  • Plug the VW3A1113 keypad into the HMI RJ45 port for setup.
  • Change the fan in under 5 minutes. No special tools needed.
  • Clean the heatsink at each service visit. Dust cuts cooling.

Compatibility Notes

  • Runs asynchronous motors, PMSM, and reluctance motors in open loop.
  • Ships with Modbus RTU on two RJ45 ports.
  • Add the VW3A3607 module for PROFIBUS DP V1. Thus it fits plant networks.
  • Add the VW3A3203 or VW3A3204 in Slot A for more I/O.
  • Works with the optional passive filter VW3A46xxx for THDi under 10%.

Certifications

  • CE (EMC directive)
  • CSA C22.2 No. 274 (Canada)
  • IEC/EN 60721 class 3C3 / 3S3; mechanical class 3M3 (frames 1-6)
  • IEC/EN 61800-5-1 overvoltage category II for relay supply
  • UL listing: not published in the official catalog.

Package Contents

  • ATV610C11N4Z drive
  • Installation manual EAV64381
  • Safety sheet
  • Quick start guide

Best Fit: Equipment and Applications

  • HVAC fans: air handling and cooling towers
  • Water pumps: supply, booster, and irrigation stations
  • Wastewater: aeration blowers and transfer pumps
  • District energy: circulation pumps in plants
  • Process cooling: large fans in dry or wet rooms

FAQ

  • Q: My pump motor overheats at low speed. What should I check?
    A: Fans on motors cool less at low speed. Check the motor rating for variable torque. Then set the U/f quadratic curve. If heat persists, add a forced-air fan to the motor.
  • Q: The drive trips on overvoltage during pump stop. Why?
    A: Fluid in the pipe pushes the motor after stop. Add a 27 N·m-checked external resistor on PA/+ and PB. Or set a longer deceleration ramp. Both steps reduce the trip risk.
  • Q: Harmonic levels at my site are too high. Can this drive help?
    A: The built-in DC choke lowers harmonics. But THDi under 10% needs the passive filter VW3A46xxx. Check your grid code first. Then size the filter for the load.
  • Q: Can I add a keypad after I buy the drive?
    A: Yes. The VW3A1113 keypad plugs into the HMI RJ45 port. This N4Z version ships without a display. Add the keypad when local setup is needed.
  • Q: The fan makes noise after two years. Is that a problem?
    A: It may be dust on the blades. Clean the fan and heatsink first. If the noise stays, swap the fan. It takes under 5 minutes and needs no special tools.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV610C11N4Z Schneider Easy Altivar 610 110 kW Pump Fan Drive”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart