ATV320U40N4W: Compact 4 kW Drive for Demanding Machines

The ATV320U40N4W is a Schneider Electric variable speed drive from the Altivar Machine ATV320 series. It delivers 4 kW (5 HP) on a 380 to 500 V three-phase supply. Moreover, the IP66 wall-mount enclosure suits dusty and wet plant areas. An integrated category C2 EMC filter also cuts wiring effort. Therefore, this model fits conveyors, pumps, fans, and simple machine axes.

Key Technical Data

Below are the core ratings. In addition, the list covers I/O, communication, and physical data.

  • Brand: Schneider Electric
  • Model: ATV320U40N4W
  • Series: Altivar Machine ATV320
  • Module type: IP66 wall-mounting three-phase variable speed drive
  • Motor power: 4 kW (5 HP) at 380 to 500 V three-phase
  • Supply voltage: 380 to 500 V three-phase, -15%/+10%, 50/60 Hz
  • Nominal output current: 9.5 A at 4 kHz switching frequency
  • Transient output current: 14.3 A for 60 s (150% of In)
  • Output frequency range: 0.1 to 599 Hz
  • Switching frequency: 2 to 16 kHz, factory set 4 kHz
  • Overload capacity: 150% of nominal current for 60 s
  • Overload torque: up to 200% Tn over-torque, 170% Tn braking torque
  • Control modes: U/F ratio, sensorless flux vector control, sensorless PM motor vector control
  • Analog inputs: 3 inputs, bipolar differential ±10 V, 0 to 10 V, and 0 to 20 mA
  • Digital inputs: 6 inputs, 4 configurable 24 V DC sink/source, 1 PTC probe, 1 pulse input up to 20 kHz
  • Digital output: 1 configurable 24 V DC sink/source, max 100 mA
  • Analog output: 1 output, 0 to 10 V or 0/4 to 20 mA, 10-bit resolution
  • Relay outputs: 1 NO/NC contact plus 1 NO contact, 3 A at 250 VAC
  • Pulse output: 1 output, 24 V, max 32 kHz, 0.1 A
  • Safety inputs: 1 STO input plus 4 configurable safety inputs
  • Built-in ports: 1 RJ45 port for CANopen and Modbus Serial line
  • Expansion slot: 1 slot for Modbus TCP/EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET modules
  • Maximum input current: 13.7 A at 380 V, 10.6 A at 500 V
  • Apparent power: 9.2 kVA at 500 V maximum
  • SCCR: 5 kA maximum
  • Power dissipation: 111 W at In
  • Braking: external resistor connection, 36 Ω minimum
  • Dimensions (H x W x D): 340 x 250 x 235 mm
  • Weight: 7.800 kg (17.196 lb)
  • Terminal torque: 1.4 N·m, Frame 3
  • Wire cross-section: 2.5 to 6 mm², Frame 3
  • Installation clearance: 100 mm minimum around the drive, vertical mounting ±10°

Environmental Tolerance and Noise Immunity

  • Operating temperature: -10 to +50 °C without derating, up to 60 °C with derating
  • Storage temperature: -25 to +70 °C
  • Relative humidity: 5 to 95%, no condensation, no dripping water
  • Protection rating: IP66 enclosure
  • Altitude: no derating up to 1000 m, then 1% current derating per 100 m up to 3000 m
  • EMC filter: integrated category C2 filter
  • Shielded motor cable: 10 m maximum at 4 kHz, category C2 or C3
  • Immunity: built to EN/IEC 61800-3 for industrial environments

Installation Guide

  • First, mount the drive vertically on a wall. Keep ±10° tilt at most.
  • Then leave 100 mm free space on all sides for airflow.
  • Use 2.5 to 6 mm² wire. Also tighten terminals to 1.4 N·m.
  • Connect the motor cable shield to the drive ground plate.
  • Moreover, keep shielded motor cable under 10 m at 4 kHz.
  • Add an external braking resistor of 36 Ω or more if you need fast stops.
  • Finally, use the RJ45 port for CANopen or Modbus Serial line wiring.

Setup and Maintenance Convenience

  • One In rating keeps selection simple. Therefore, no Normal Duty or Heavy Duty split is needed.
  • Factory 4 kHz setting works for most applications. However, raise it only with derating.
  • Six digital inputs and three analog inputs cover common machine signals.
  • The STO input also supports SIL3 and PLe safety architectures.
  • Optional VW3A1111 or VW3A1101 graphic terminals therefore speed up commissioning.
  • The IP66 enclosure allows washdown cleaning in food and packaging lines.
  • Fewer cabinet parts are needed because the EMC filter is inside.

Compatibility Notes

  • The drive works with asynchronous motors and synchronous PM motors.
  • It communicates over CANopen and Modbus Serial line out of the box.
  • Additionally, one module adds Modbus TCP/EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET.
  • It pairs with GV2 circuit breakers using the mounting bracket.
  • Similarly, it fits DIN rail mounting plates and UL Type 1 conformity kits.
  • It also supports external braking resistors from the catalog list.

Certifications

  • UL 508C and UL 61800-5-1
  • CSA 22.2 N274
  • EN/IEC 61800-3 category C2/C3
  • EN/IEC 61800-5-1
  • IEC 61800-5-2 up to SIL3 and IEC 61508 SIL3
  • IEC 13849-1 PLe
  • IEC 60721-3-3 class 3C3/3S2
  • RCM, EAC, KC

Packing List

  • 1 x ATV320U40N4W drive
  • 1 x installation manual NVE41289
  • 1 x safety and compliance leaflet
  • Terminal hardware as shipped by the factory

Optional items ship separately. For example, the display terminal, communication module, braking resistor, and mounting kits.

FAQ

Q: Can this drive run a 5 HP motor on 480 V?

A: Yes. The 4 kW rating matches a 5 HP motor at 380 to 500 V three-phase.

Q: Does it include a braking resistor?

A: No. You must add an external resistor of 36 Ω or more for dynamic braking.

Q: Which network works without an extra module?

A: CANopen and Modbus Serial line run on the built-in RJ45 port.

Q: Can I mount it in a washdown area?

A: Yes. The IP66 enclosure protects against dust and water jets.

Q: What happens above 4 kHz switching frequency?

A: The drive needs power derating. Therefore, check the derating curve before you raise it.

Q: How long can the motor cable be?

A: Keep shielded cable at 10 m or less at 4 kHz for category C2 or C3.

Q: Does it meet machine safety standards?

A: Yes. The STO input reaches SIL3 and PLe. Moreover, SS1, SLS, SMS, and GDL are configurable.

Q: From experience, what do installers check first?

A: They check clearance and torque. For example, tighten terminals at 1.4 N·m and keep 100 mm free space.

Q: From experience, what causes nuisance trips?

A: Long motor cables and poor shielding. Therefore, ground the shield well and stay within 10 m.

Q: From experience, how do teams cut setup time?

A: They save one motor parameter set. Then they copy it to similar drives on the line.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV320U40N4W Schneider Altivar Machine 4 kW IP66 VFD”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart