Over 50,000 hot-selling automation module components.

AI950S ABB S900 4-channel Temperature Input Module 3KDE175521L9500

0 Reviews
10 in stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: AI950S
Brands:

Product details

Product overview

ABB AI950S 3KDE175521L9500 is a high‑integrity S900 I/O module for hazardous areas. It accepts signals from Pt100, Pt1000, Ni100 RTDs and thermocouples types B, E, J, K, L, N, R, S, T, U. The unit fits directly in Zone 1 installations and communicates via PROFIBUS DP. Field mounting reduces marshalling cabinets and wiring cost. The housing is rugged, error‑tolerant and designed for live replacement.

Technical specifications – tree structure

  • Brand: ABB
    • Model: AI950S
      • Order suffix: 3KDE175521L9500
        • Type: Analog input module
          • Channels: 4
            • Input 1‑4: RTD / TC / mV
              • RTD support: Pt100, Pt1000, Ni100, 0‑3kΩ
                • Connection: 2‑wire, 3‑wire, 4‑wire
              • Thermocouple support: B, E, J, K, L, N, R, S, T, U
                • Cold junction: Internal / external
              • mV range: ±100 mV
            • Isolation: Channel‑to‑channel, input/bus, input/power
            • HART: Yes (on each channel)
          • Communication: PROFIBUS DP
            • Redundancy ready: Power & bus (module non‑redundant)
          • Diagnostics: Wire break / short / CJC / FDT/DTM
          • Environment: ATEX Zone 1, G3 coating, –20…+60°C
  • Measurement specifications
    • RTD accuracy: ±0.1 % of span typ.
    • TC accuracy: ±0.5 °C (with CJC)
    • Resolution: 16‑bit
    • Linearity error: < 0.02 %
    • Frequency response: 10 Hz (integrated noise rejection)
  • Physical data
    • Dimensions (W/D/H): 20 / 104 / 104 mm
    • Weight: 0.135 kg
    • Material: G3 coated PCB & housing

Installation & mounting – tree view

  • Area classification: Zone 1 / safe area
    • Mechanics: S900 base plate
      • Mounting: DIN rail TS35
      • Field connection: Screw terminals (intrinsically safe)
  • Wiring: Direct to Zone 0/1/2 sensors
    • Cable type: Shielded recommended for TC/mV

Maintenance & diagnostics – tree

  • Live maintenance: Hot swap & hot config
    • Module exchange: No primary power cut
    • Parameter update: In‑run via PROFIBUS
  • Self‑diagnostics:
    • Per channel: Open / short detection
      • Indication: LED & bus status
    • CJC supervision: Internal sensor watch
    • FDT/DTM: Full waveform & history

Compatibility & system integration – tree

  • System: ABB S900 I/O
    • Network: PROFIBUS DP (any master)
    • Coupler required: e.g. 3KDE175511L9300 (Zone 1)
  • Device support:
    • HART: Yes, transparent
    • Intrinsic safety: Ex ia for all channels

Certifications – tree

  • Hazardous area: ATEX II 2(1) G Ex ia [ia Ga] IIC T4 Gb
    • Zone: 1 (module), 0/1/2 (sensors)
  • Industrial: CE, RoHS, WEEE
    • Corrosion: ISA‑S71.04 G3
    • Climate: 93 % RH @ 40 °C, –20…+60 °C

Package & warranty – tree

  • Included: AI950S module + quick guide
    • Optional: Manual download
  • Warranty: 12 months
    • Shipping: FedEx, UPS, DHL (tracked)

Typical applications – tree

  • Oil & gas: Zone 1 temperature monitoring
    • Example: Wellhead RTDs
  • Chemical: Reactor TC arrays
    • Example: Type K on cracking towers
  • Pharma: Sterilizers with Pt100
    • Example: 3‑wire Pt100 in autoclaves
  • Field replacement: Remote I/O cabinets removal

Diagnostic capabilities – tree

  • Hardware: Per‑channel fault LEDs
    • Wire break / short: Individual flags
  • Software: FDT/DTM detailed logs
    • History: Min/max, trends
    • CJC status: Internal sensor readback

FAQ – experience based selection

  • Can I use AI950S with a redundant coupler?
  • Yes. The module works with redundant PROFIBUS DP couplers; the S900 system supports redundancy at power and bus level.
  • What is the difference between AI950S and AI950?
  • AI950S includes ATEX Zone 1 certification and intrinsic safety per channel. AI950 is for safe area only.
  • Do I need external safety barriers?
  • No. Each channel is galvanically isolated and Ex ia rated. You connect field devices directly.
  • How to select between internal and external CJC?
  • Use internal for short cable runs; use external terminal CJC for long distances or high accuracy.
  • Which RTD connection gives best accuracy?
  • 4‑wire eliminates lead resistance. 3‑wire is good for most industrial needs. 2‑wire is acceptable for short, thick wires.
  • Can this module read potentiometers?
  • Yes, in 0‑3 kΩ mode you can connect 2‑ or 3‑wire potentiometers.
  • Is G3 coating standard?
  • Yes, all AI950S modules ship with ISA‑S71.04 G3 conformal coating.
  • What is the typical lead time?
  • Stock items ship within 24h via FedEx/UPS/DHL. Please inquire for bulk.
  • Which field housings fit S900 mechanics?
  • Standard S900 terminal bases (order separately if needed).

Contact & ordering

Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/

Specifications

  • BrandABB
  • Part NumberAI950S
  • Warranty12 Months

Additional information

Weight1.28 kg
Dimensions273 × 40 × 252 mm
Country Of Origin

United States

Document Download

Customers Reviews

There are no reviews yet.

Be the first to review “AI950S ABB S900 4-channel Temperature Input Module 3KDE175521L9500”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart