VKV021 Vibration Monitor by ifm: Simple Machine Health Guard
- VKV021 watches overall machine vibration. It follows ISO 10816.
- Jedna MEMS akcelerometr axis reads the signal. The range is 0…25 mm/s RMS.
- Pokrývá to 10…1000 XNUMX Hz. That band catches most pump and fan faults.
- Dvě setpoint rings set the trip point. The scale reads direct, so no tool is needed.
- A Výstup 4…20 mA sends live trend data to the PLC.
- A PNP normally closed contact trips an alarm on high vibration.
- Jedno Závit M8 x 1.25 mounts straight into a tapped boss. Torque to 15 Nm.
- Doba odezvy je 1…60 s. You can filter out short shocks and keep real faults.
- Jedno IP 67 housing shrugs off washdown, dust and oil mist.
- This part suits condition monitoring on a budget. It needs no software and no gateway.
Technická data
- Základní identita
- Značka: ifm
- Model: VKV021
- Série: VKV vibration monitor
- Type code: vibration monitor
- Module type: vibration switch with analog output
- Měření výkonu
- Zásada: MEMS akcelerometr, 1 axis
- Rozsah vibrací: 0…25 mm/s RMS
- Frekvenční rozsah: 10…1000 XNUMX Hz
- Chyba měření: < ±3 % of final value
- Linearita: 0.25%
- Dostupnost podpory: 1…60 s, nastavitelný
- Setpoint: two positioning rings with direct scale
- Elektrické údaje
- Zásobování: 18…32 V DC nominální
- Aktuální losování: <50 mA
- Digitální výstup: 1 x PNP, NC
- Pokles napětí: max. 2 V
- Aktuální zatížení: 500 mA stálý
- Analogový výstup: 4…20 mA, max. load 500 Ω
- Ochrana proti zkratu: ano, pulzní
- Ochrana proti přetížení: ano
- Třída ochrany: III
- Teplotní rozsah
- Provozní: -25 ... 80 ° C
- UL use: keep below 80 °C
- Skladování: -25 ... 80 ° C
- Humidity: not published by the manufacturer
- Odolnost vůči prostředí
- Hodnocení ochrany: IP 67
- Šokovat: 400 g
- Bydlení: PBT, PC, FKM, stainless steel 1.4404 / 316L
- MTTF: 510 let
- Odolnost proti hluku
- ESD: 4 kV kontakt / 8 kV vzduch
- VF pole: 10 V / m
- Burst: 2 kV
- Vedená RF: 10 V
- Fyzické údaje
- Montážní závit: M8 x 1.25
- Točivý moment: 15 Nm
- Hmotnost: 113.5 g
- Připojení: M12, A-coded, 4-pin
- Envelope size: not published by the manufacturer
- Interface note
- No IO-Link. No fieldbus. Switching plus analog only.
Nejlepší vybavení a aplikace
- Rotační stroje
- Pumps, fans and blowers in process lines.
- Gearboxes and small motors on conveyors.
- Plant and building services
- HVAC air handlers and cooling tower fans.
- Chillers and compressors in utility rooms.
- Těžký průmysl
- Mixers, agitators and crushers.
- Machine tools with spindle watch needs.
- Typické pracovní pozice
- Early warning of bearing wear and imbalance.
- Alarm on a rise in overall vibration level.
- Trend logging through the 4…20 mA loop.
Montážní průvodce
- Pick a rigid spot on the bearing housing. Thin sheet metal gives false readings.
- Klepněte na a M8 x 1.25 boss. Keep the face flat and clean.
- Apply the sensor. Tighten to 15 Nm. Do not over torque.
- Point the measuring axis along the expected vibration path.
- Zapojte M12 4kolíkový cable. Hand tighten the nut.
- Power up. The zelená LED confirms operation.
Nastavení a údržba
- Turn the two rings to set the trip level. Read the value on the scale.
- Set response time to match the machine. Long times skip start-up shocks.
- Podívejte se žlutá LED during a test run. It shows the switch state.
- Compare the loop current with a meter. This proves the analog path.
- Clean the body with a damp cloth. Avoid high pressure on the connector.
- Recheck torque after the first weeks of service. Vibration can loosen joints.
Certifikace
- CE a UKCA výrazný.
- CULus v seznamu.
- EMC tested to EN-61000 4 parts 2, 3, 4 and 6.
- Třída ochrany III. Uzemněte rám stroje běžným způsobem.
Co se dodává v krabici
- 1 x VKV021 monitor vibrací
- M12 4-pin connector socket on the unit. Cable sold as an option.
Nejčastější dotazy
- Does it need a PC or software to start?
- No. The rings set the limit by hand.
- You can run it with just a power supply and a relay.
- What trip level should I pick?
- Start near the ISO 10816 limit for your machine class.
- Then raise it a little above the normal running value.
- Why does the alarm pulse at start-up?
- Motors shake hard during run-up.
- Set a longer response time to mask that short peak.
- Can I read the trend in my control room?
- Yes. Feed the 4…20 mA loop into an analog input card.
- The current rises as vibration grows, so trends are easy to chart.
- How do I know the mount is good?
- Tap the housing with a screwdriver handle and watch the current move.
- A weak change points to a soft mount or a loose thread.















Nejsou žádné hodnocení.