Produkto detalye
E82EV302-4C200 Lenze 8200 vector Inverter – 3.0 kW Speed Control for Demanding Machines
E82EV302-4C200 ay isang built-in na vector-controlled frequency inverter mula sa Lenze 8200 vector series. It drives a 3.0 kW four-pole asynchronous motor on a 400 V class supply. The unit delivers 7.3 A rated output at 8 kHz. It handles 11.0 A for 60 s. This makes it a solid choice for periodic overload duty.
The drive offers sensorless vector control. It keeps torque stable at low speed. Output frequency reaches 650 Hz. You can select 2, 4, 8 or 16 kHz switching frequency. The factory setting is 8 kHz. A built-in brake transistor saves panel space. The C2xx variant ships without an integrated EMC filter. Add an external filter where class C2 limits apply.
- Brand: Lenze
- Modelo: E82EV302-4C200
- Serye: 8200 vektor
- Tungkulin: built-in na vector-controlled frequency inverter
- Na-rate na kapangyarihan ng motor: 3.0 kW (4-pole asynchronous motor)
- Klase ng boltahe ng pangunahing kuryente: 400 V
- Na-rate na kasalukuyang output: 7.3 A sa 8 kHz
- Max. kasalukuyang output: 11.0 A sa loob ng 60 segundo (pana-panahong siklo ng pagbabago ng karga)
- Kadalasan ng output: 0…650Hz
- Dalas ng paglipat: 2 / 4 / 8 / 16 kHz selectable (8 kHz factory setting)
- Kakayahang mag-overload: 1.8 x na-rate na metalikang kuwintas sa loob ng 60 segundo
- Pinagsamang transistor ng preno: oo (built-in na chopper hanggang 11 kW)
- Pinagsamang pansala ng EMC: no (C2xx variant)
- Supply para sa boltahe: 3/PE 320…550 V AC (45…65 Hz); DC 450…775 V DC alternative
- Pagkawala ng kuryente: 145 W sa na-rate na kasalukuyang / 8 kHz
- Operating temperatura: -10…+55 °C, derated 2.5 %/°C above +40 °C
- Temperatura Storage: -25… + 60 ° C
- Kamag-anak na halumigmig: average 85 % RH, no condensation (climatic class 3K3 per EN 50178)
- Rating ng proteksyon: IP20
- Mga Dimensyon (H × W × D): 240 × 100 × 140 mm
- Timbang: 2.9 kg
Technical Data and Measured Performance
- Saklaw ng kontrol: 0…650 Hz output frequency, full torque down to standstill in vector mode
- Dalas ng tugon: fast current loop for stable torque under shock loads
- Torque sensitivity: 1.8 x rated torque for 60 s supports heavy starts
- Linearity: smooth speed hold across the 320…550 V AC band
- resolution: fine speed steps via serial bus setpoint
- Hanay ng temperatura: -10…+55 °C with 2.5 %/°C derating above +40 °C
- Pagpaparaya sa kapaligiran: 3K3 class, 85 % RH average, no condensation
- Kasanayan sa ingay: meets EN 50178 climate class; add external EMC filter for class C2
- Opsyon sa suplay ng DC: 450…775 V DC rail input for common DC bus systems
Gabay sa Pag-install
- Mount the unit vertically on a flat panel. Keep the IP20 enclosure clear of dust and water.
- Allow free air above and below the 240 × 100 × 140 mm housing for convection.
- Wire the 3/PE 320…550 V AC supply with a suitable breaker and earth conductor.
- Connect the motor cable short and screened. Earth the screen at both ends.
- Fit an external EMC filter when the machine must meet class C2 limits.
- Use the built-in brake chopper with a matched resistor for fast stops.
- Derate output current by 2.5 %/°C when the cabinet runs above +40 °C.
Kadalian ng Pagkomisyon at Pagpapanatili
- Set motor data once. The vector control then adapts to the load.
- Use the RS232/485 system bus for fast parameter upload and clone.
- Two plug-in slots accept function or communication modules. Units above 15 kW carry three.
- Check fan and heatsink every service interval. Clean fins in dusty rooms.
- Store spare parameters on a PC. Swap a failed unit in minutes.
Mga Tala sa Pagkatugma
- motor: 3.0 kW four-pole asynchronous motor, 400 V class
- Fieldbus: PROFIBUS DP, CANopen, DeviceNet, INTERBUS and AS-Interface via plug-in modules
- Native bus: Lenze system bus over RS232/485
- migration: Lenze confirms the i950 emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library (AKB 321231 / 316137)
- Kapalit: no drop-in same-order-code swap. Plan a migration project.
- Type key: this order code uses Lenze short notation. The canonical 8200 vector key is E82EVxxxKx…
Mga Sertipikasyon at Siklo ng Buhay
- Klase ng klima 3K3 ayon sa EN 50178
- IP20 rating ng proteksyon
- Status: legacy product on the official Lenze previous products page
- Migration path to the i950 is officially confirmed
- Data audit status: OPISYAL_NA-VERIFY, last checked 2026-10
Mga Nilalaman ng Pakete at Garantiya
- 1 x E82EV302-4C200 Lenze 8200 vector inverter
- 1 x printed quick start guide
- 1 x terminal and connector set as shipped by the factory
- Warranty: 12 buwan
- Ipadala: ships within 12 to 24 hours
- Mga Courier: FedEx, UPS at DHL
Repasuhin ng Dalubhasa
The 8200 vector still earns respect on the shop floor. Torque hold at low speed is strong for a drive of this age. The 1.8 x overload window covers conveyor jams and mixer starts. The built-in chopper removes one extra box from the panel. The missing EMC filter is the main gap. Budget for an external filter on CE-critical machines. Source units now carry legacy status. Stock spares while you plan the i950 move.
Pananaw ng Tagapamahala
Buy this unit when a machine must stay online and the panel already uses Lenze system bus. The plug-in slot design keeps fieldbus options open. Keep one spare on the shelf. Lead times for legacy stock will only grow. The i950 path is real, but it is a project, not a swap. Price the migration before you promise a delivery date.
Kagamitan at Aplikasyon na Pinakamahusay na Pagkasyahin
- Conveyors and transport lines with frequent starts
- Mga mixer at agitator na may mataas na breakaway torque
- Packaging machines that need 650 Hz top speed
- Pumps and fans on 400 V class supplies
- Textile and wire winders on common DC bus
- Retrofit projects that already run Lenze system bus
FAQ
- May kasama bang EMC filter ang drive na ito?
The C2xx variant ships without one. Add an external filter for class C2 sites. - Can I run a 3.0 kW motor at full load?
Yes. Rated output is 7.3 A at 8 kHz. That suits a standard four-pole 3.0 kW motor. - How long can it deliver 11.0 A?
For 60 s in a periodic load change cycle. Do not hold that current continuously. - What fieldbus options exist?
PROFIBUS DP, CANopen, DeviceNet, INTERBUS and AS-Interface via plug-in modules. - Is a direct replacement still sold?
No. Lenze lists no same-order-code drop-in. The i950 is the official path. - What does the i950 migration involve?
Lenze states the i950 emulates 8200 vector behaviour with the i950 PROFIBUS module and L_ICIP library. - Base sa karanasan, ano ang unang nabibigo?
Cooling paths in dusty rooms. Clean the heatsink each service and the unit runs long. - How do I avoid a wrong buy?
Check the type key E82EVxxxKx… and confirm the C2xx filter variant before you order.
Gabay sa Pagbili
- Match rated current to motor current, not just kW.
- Confirm the supply band: 320…550 V AC or 450…775 V DC.
- Decide on the EMC filter before you mount the panel.
- List the fieldbus you need and order the right plug-in module.
- Plan the i950 migration if the machine must run beyond 2030.
- Order a spare while legacy stock is still available.
Mga Tanong? Email sales@powergearx.com o mensahe + 86 18030005825 sa WhatsApp. Mabilis kaming tumutugon.
Karapatang-ari © 2026 Powergear X Automation Limited. Lahat ng karapatan ay nakalaan.
Orihinal na Pinagmulan: https://www.powergearx.com/