Product details
Product Overview – Honeywell XNXXSC1SS
XNXXSC1SS – Honeywell gas cartridge for CO (carbon monoxide). Smart, selectable range, fast response. Designed for fixed and portable gas detection systems.
Technical Specifications – Hierarchical View
- Gas Type
- Carbon Monoxide (CO)
- Measurement Range
- Selectable full scale: 100 to 500 ppm
- Default range: 300 ppm
- Step increment: 100 ppm
- Sensitivity & Accuracy
- Lower detectable limit: 5 ppm
- Accuracy: ±2 ppm (typical)
- Response Time (T50 / T90)
- T50: < 15 seconds
- T90: < 30 seconds
- Calibration
- Selectable cal gas: 30 % to 70 % of full scale
- Default cal point: 100 ppm
- Environment & Durability
- Operating temp: -40 °C to +55 °C (-40 °F to 131 °F)
- Humidity resistance: 15 % to 90 % RH (non-condensing)
- Pressure range: 0.9 to 1.1 atm
Manager’s Insight – Expert Review
This sensor excels in harsh conditions. Its wide temperature range and fast T90 response make it reliable for safety-critical areas. The selectable range gives flexibility – one cartridge fits many applications. For CO monitoring, this is a cost-effective, proven choice.
Compatible Devices & Applications
- Fixed gas detectors – Honeywell XNX series, other 4-20 mA systems
- Portable gas monitors – personal safety devices
- Industrial environments – parking garages, warehouses, tunnels
- HVAC controls – indoor air quality monitoring
- Process safety – chemical plants, refineries
Professional FAQs
- How do I change the full scale range?Use the configuration menu on the transmitter or software tool. Select 100, 200, 300, 400, or 500 ppm.
- What is the default calibration gas value?Default is 100 ppm CO. You can set it between 30 % and 70 % of the selected range.
- Can I use this cartridge in extreme cold?Yes, it works from -40 °C to +55 °C. No warm-up time needed in that range.
- Is the sensor field-replaceable?Yes, it is a plug-in cartridge. Replacement takes less than 5 minutes.
- What is the expected sensor life?Typical life is 3–5 years in clean air. Reduce exposure to high CO for longer life.
Purchasing & Selection Guide
- Choose XNXXSC1SS for CO only. For other gases, see Honeywell XNX series.
- Select 100 ppm range for low-level monitoring; 500 ppm for high-risk areas.
- Order calibration gas kit separately (CO in air or nitrogen).
- Ensure your transmitter supports XNX cartridge types (4-20 mA or Modbus).
Warranty & Shipping
- Warranty: 12 months against defects.
- Dispatch: 12–24 hours after order.
- Shipping: FedEx, UPS, DHL – with tracking number.
Comparison – Similar Models
- XNXXSC1SS (CO, 100-500 ppm) – this model
- XNXXSC1H2S – Hydrogen sulfide, 0-100 ppm
- XNXXSC1O2 – Oxygen, 0-25 % Vol
- XNXXSC1LEL – Combustible gases, 0-100 % LEL