XNX-AMSE-NHCB1 Universal Transmitter | Catalytic Bead Sensor 0-100% LEL

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: XNX-AMSE-NHCB1
Brands:

Product details

Product Description

The Honeywell XNX-AMSE-NHCB1 is a universal transmitter for gas detection. It offers a HART over 4-20mA output and a local HART interface port. This model includes an MPD catalytic bead sensor for 0-100% LEL range. It comes with ATEX/IECEx/INMETRO approvals for hazardous areas. The housing is made of painted 316 stainless steel with three M25 entries.

Technical Specifications

  • Brand: Honeywell
  • Model: XNX-AMSE-NHCB1
  • Output Signal: HART over 4-20mA
  • Local Interface: HART port for configuration
  • Sensor Type: Catalytic bead (MPD)
  • Measuring Range: 0-100% LEL
  • Frequency Response: Fast T90 response
  • Sensitivity: High sensitivity to combustible gases
  • Linearity: Excellent linear output
  • Resolution: 1% LEL
  • Operating Temperature: -40°C to +70°C
  • Environmental Resistance: IP66/67 rated enclosure
  • Interference Immunity: Resistant to RFI/EMI
  • Enclosure Material: 316 stainless steel with paint
  • Cable Entries: 3 x M25
  • Approvals: ATEX, IECEx, INMETRO
  • Weight: 5 kg

Installation & Setup

  • Mount the transmitter securely with M25 cable glands.
  • Connect power and 4-20mA loop to terminals.
  • Use the local HART port for calibration and configuration.
  • Follow hazardous area installation guidelines (ATEX/IECEx).
  • Ensure proper grounding for EMI protection.

Debugging & Maintenance Ease

  • Front-facing HART interface allows easy diagnostics.
  • Replace the catalytic sensor cartridge quickly.
  • Auto-calibration routine reduces manual effort.
  • Self-diagnostic checks for sensor health and faults.
  • Clear LED status indicators for operational status.

Compatibility

  • Works with Honeywell toxic and oxygen electrochemical sensors.
  • Interfaces with any 4-20mA input control system.
  • Compatible with HART handheld communicators.
  • Supports remote monitoring via HART multiplexers.

Certifications & Approvals

  • ATEX – Zone 1 and 2 hazardous locations
  • IECEx – International certification for explosive atmospheres
  • INMETRO – Brazilian certification for safety
  • CE marked for European compliance

Package Contents

  • XNX-AMSE-NHCB1 Universal Transmitter
  • MPD catalytic bead sensor (0-100% LEL)
  • IS barrier and adaptor for electrochemical cartridges
  • Mounting bracket and hardware
  • Quick start guide and manual (digital)

Warranty & Shipping

12-month warranty covers manufacturing defects. Ships within 12-24 hours via FedEx, UPS, or DHL (express).

Expert Review

The Honeywell XNX-AMSE-NHCB1 stands out for its robust construction and smart HART capabilities. It is a reliable choice for demanding environments like oil refineries or chemical plants. The local HART interface makes configuration and maintenance intuitive, even for field technicians. Its certified safety (ATEX/IECEx) ensures compliance in explosive zones. This transmitter delivers accurate readings with fast response, critical for safety systems.

Manager’s Insight

Investing in XNX-AMSE-NHCB1 reduces downtime with easy sensor swaps and diagnostic features. It is a cost-effective solution for multi-point gas detection systems. The rugged 316SS housing and IP66/67 rating keep it operational in harsh weather and corrosion risks. We recommend this device for fixed installations where reliability and low maintenance are priorities. Its versatility with electrochemical sensors makes it a future-proof asset.

Applications

  • Oil and gas refineries for LEL monitoring
  • Chemical processing plants
  • Pharmaceutical manufacturing
  • Wastewater treatment facilities
  • Mining and tunneling operations
  • Paint and coating industries

Frequently Asked Questions

  • What does the sensor measure?
  • It measures combustible gases from 0 to 100% LEL.
  • Is it suitable for outdoor use?
  • Yes, with IP66/67 protection, it handles rain and dust.
  • Can I use it with other sensor types?
  • Yes, with the electrochemical cartridge adapter.
  • How often should I calibrate?
  • Recommended every 3-6 months, based on usage.
  • What power supply is needed?
  • Standard 24V DC (12-32V DC range).
  • Is the sensor replaceable?
  • Yes, the catalytic bead sensor is user-replaceable.
  • Does it have a display?
  • No display, but HART provides full parameter access.
  • What is the response time?
  • T90 response in less than 30 seconds.

Experience-based Q&A

  • How to avoid false alarms?
  • Ensure proper grounding and avoid sensor contamination from silicones.
  • Best practice for installation?
  • Mount the unit away from direct splash and vibration sources.
  • Can I extend cable length?
  • Up to 300 meters with proper shielded cable.

Selection Guide

  • Choose this model if you need ATEX/IECEx approval for Zone 1.
  • Select for applications requiring 4-20mA with HART diagnostics.
  • Ideal for projects needing a robust, painted stainless steel housing.
  • Consider for easy integration with existing control systems.

For inquiries: sales@powergearx.com | +86 18030005825

Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/

Specifications

  • BrandHoneywell
  • Part NumberXNX-AMSE-NHCB1
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “XNX-AMSE-NHCB1 Universal Transmitter | Catalytic Bead Sensor 0-100% LEL”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart