Over 50,000 hot-selling automation module components.

XNX-AMAI-RNNNN Universal Transmitter by Honeywell – ATEX/IECEx, 4-20mA

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: XNX-AMAI-RNNNN
Brands:

Product details

XNX-AMAI-RNNNN Universal Transmitter by Honeywell

Designed for industrial safety. The XNX-AMAI-RNNNN transmitter delivers reliable gas detection. It supports Searchline Excel, Optima Plus, and generic 4-20mA inputs. This unit offers HART communication via 4-20mA output. It includes 3 fault/alarm relays. Built for harsh environments. ATEX/IECEx approved. Housing is painted aluminium with M25 entries. Surface mount with integral lugs. Optional pipe or ceiling mount available.

Key Features

  • Approval – ATEX and IECEx certified for hazardous areas
  • Entry Type – 5 x M25 cable entries
  • Material – Durable painted aluminium enclosure
  • Personality – Interface for infrared products (Searchline Excel, Optima, 4-20mA)
  • Relay Option – 3 fault/alarm relays included
  • Mounting – Surface mount via integral lugs; optional pipe kit (Ø100-150mm) or ceiling bracket
  • Output – HART over 4-20mA analog signal

Technical Specifications

  • Brand – Honeywell
  • Model – XNX-AMAI-RNNNN
  • Series – XNX Universal Transmitter
  • Measurement Range – Sensor dependent (NNN = none supplied)
  • Frequency Response – Fast response for real-time monitoring
  • Sensitivity – High sensitivity for low gas concentrations
  • Linearity – Excellent linearity over full range
  • Resolution – High resolution for accurate readings
  • Temperature Range – -40ºC to +65ºC (operating)
  • Storage Temperature – -40ºC to 75ºC
  • Humidity – 0-99% RH non-condensing
  • Operating Pressure – 90-110 kPa
  • Environmental Resistance – IP-rated for dust and moisture
  • Immunity – Resistant to EMI/RFI interference
  • Dimensions – 16cm x 19.7cm x 11.4cm (6.1″ x 7.8″ x 4.5″)
  • Weight – 5 kg

Installation Guide

  • Mounting – Use integral lugs for surface mounting. For pipe mounting, order optional kit (Ø100-150mm). Ceiling bracket also available.
  • Cable Entries – 5 x M25 entries for flexible wiring.
  • Positioning – Install in clean, dry area away from direct vibration.
  • Wiring – Connect 4-20mA and relay outputs as per manual.

Commissioning & Maintenance

  • Easy Setup – Intuitive interface for quick configuration.
  • HART Communication – Digital adjustment via 4-20mA loop.
  • Self-Diagnostics – Continuous health checks with fault relay alerts.
  • Maintenance – Minimal routine checks; sensor replacement only.

Compatibility

  • Gas Detectors – Searchline Excel, Searchpoint Optima Plus.
  • Inputs – Generic 4-20mA devices.
  • Control Systems – Works with PLC, DCS, and SCADA.

Certifications

  • ATEX/IECEx – Zone 1 and 2 hazardous areas.
  • CE Mark – Conforms to European standards.

Package Includes

  • XNX-AMAI-RNNNN transmitter unit
  • Mounting lugs (integral)
  • Quick start guide
  • Certificate of conformity

Warranty & Shipping

  • Warranty – 12 months from invoice date.
  • Shipping – 12-24 hours dispatch.
  • Carriers – FedEx, UPS, DHL worldwide.

Expert Review

Manager’s Insight: This transmitter is a workhorse. Its robust aluminium housing and wide temperature range make it ideal for offshore and chemical plants. The HART protocol simplifies integration. Reliable, accurate, and built to last.

Applications

  • Oil and gas platforms
  • Petrochemical refineries
  • Chemical processing plants
  • Water and wastewater treatment
  • Pharmaceutical manufacturing

Frequently Asked Questions

What is the operating temperature range?

-40ºC to +65ºC. Storage up to 75ºC.

Can I use this with third-party sensors?

Yes, it accepts generic 4-20mA inputs.

How many relays are included?

3 fault/alarm relays are standard.

What mounting options are available?

Surface mount with lugs, plus optional pipe or ceiling kit.

Is HART communication supported?

Yes, HART over 4-20mA output is enabled.

What approvals does it hold?

ATEX and IECEx certified for hazardous zones.

Can I get a pipe mount for 6″ pipe?

Yes, the optional kit fits Ø100-150mm (Ø4″-6″).

How soon can it ship?

Within 12-24 hours of order.

Selection Guide

  • Choose model XNX-AMAI-RNNNN for ATEX/IECEx and aluminium housing.
  • Select this variant for infrared gas detector interface.
  • Add relay option for additional alarm outputs.
  • Order pipe mount kit separately if needed.

Contact Information

For inquiries, email sales@powergearx.com or WhatsApp +86 18030005825.

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandHoneywell
  • Part NumberXNX-AMAI-RNNNN
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “XNX-AMAI-RNNNN Universal Transmitter by Honeywell – ATEX/IECEx, 4-20mA”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart