Product details
Product Overview
- ABB UMC22-FBP is a Universal Motor Controller from ABB.
- It protects and controls three-phase AC motors.
- Protection is electronic, not thermal.
- It also monitors the motor while running.
- Settings stay inside the unit.
- Two parts form one body:
- Current Transformer Set
- Controller Unit
- A pluggable FieldBusPlug (FBP) links it to field buses such as DeviceNet.
- Swap the plug to change the bus. No new controller is needed.
Technical Data
- Brand: ABB
- Model: UMC22-FBP
- Type: Universal Motor Controller
- Rated insulation voltage (Ui): 690 V
- Rated operating voltage (Ue): 690 V
- Current setting range (Ie): 0.24 – 63 A
- Trip class: 5, 10, 20, 30
- Poles: 3P
- Auxiliary contacts: 3NO
- Conventional thermal current (Ith): 3 A
Best Fit: Equipment and Scenes
- Pumps and fans in water plants
- Conveyors and mixers in factories
- Compressors and blowers
- Motor control centers with field bus wiring
- Retrofit jobs that need bus options
- Panels where space is tight
- Lines that need remote motor data
Expert Review
- The UMC22-FBP is a smart pick for mixed-bus plants.
- One controller, many bus choices. That cuts spare parts.
- The wide 0.24 – 63 A range covers many small and mid motors.
- Four trip classes let you match the load curve.
- Built-in CTs save wiring time.
- Settings live in the unit, so a swap is fast.
- Check the bus plug type before you order.
Manager’s Insight
- Keep one spare controller and two plug types on site.
- Most callbacks come from a wrong plug, not a bad unit.
- Label each motor with its current setting. Service gets faster.
- Stock the 63 A top end. It covers most urgent jobs.
- Ask us to check the plug code before shipping.
- Reach us at sales@powergearx.com or +86 18030005825.
FAQ
- Q: Can I change the field bus later?
- A: Yes. Change the FieldBusPlug only. The controller stays in place.
- Q: Does it need separate current transformers?
- A: No. The CT set is part of the unit.
- Q: How do I pick a trip class?
- A: Class 5 for fast trips, class 30 for heavy starts. Match the motor data sheet.
- Q: What does 3NO mean for my panel?
- A: You get three normally open contacts for status or interlock signals.
- Q: Is the 3 A Ith value a motor limit?
- A: No. It applies to the auxiliary contact circuit, not the main motor current.
- Q: Experience tip: why does a unit trip at start?
- A: The current setting is often too low, or the trip class is too fast for the load.
- Q: Experience tip: how do I plan spares?
- A: Keep one full unit plus the two bus plugs your plant uses most.