SM6100 IFM Electromagnetic Flow Sensor for Conductive Liquids
The SM6100 is a magnetic-inductive flow sensor from IFM. It measures conductive liquids with high accuracy. Three output types cover many control tasks. A 4-digit LED display shows flow and temperature. The stainless steel body fits tight machine spaces.
Core Specifications
- Brand: IFM
- Model: SM6100
- Series: SM electromagnetic flow sensor
- Type code: SMR12GGXFRKG/US-100
- Measuring principle: Magnetic-inductive
- Best fit for water and water-based media
- Needs conductivity of at least 20 µS/cm
- Viscosity below 70 mm²/s at 40 °C
- Flow range: 0.1 to 25 l/min (0.005 to 1.5 m³/h)
- Display range: -30 to 30 l/min
- Resolution: 0.02 l/min
- Switch points:
- Set point SP: 0.25 to 25 l/min
- Reset point rP: 0.1 to 24.9 l/min
- Analog start ASP: 0 to 20 l/min
- Analog end AEP: 5 to 25 l/min
- Pulse output: 0.00001 to 30000 m³
- Pulse length: 0.01 to 2 s
- Temperature monitoring: -20 to 80 °C
- Resolution: 0.2 °C
- Accuracy: ±2.5 K when flow is above 1 l/min
- Accuracy and response:
- Flow accuracy: ±(0.8% of value + 0.5% of final value)
- Repeatability: ±0.2% of final value
- Response time: 0.15 s
- Delay dS/dr: 0 to 50 s
- Damping dAP: 0 to 5 s
- Process connection: G 1/2 external thread, DN15, flat seal
- Pressure resistance: 16 bar (1.6 MPa)
- CRN max working pressure: 15.3 bar
- Medium temperature: -10 to 70 °C
- Wetted materials: Stainless steel 1.4404 / 316L, PEEK, EPDM
- Housing materials: Stainless steel 1.4404 / 316L, PBT-GF20, PC, FKM, TPE
- Installation runs:
- Inlet run: 3 x DN
- Outlet run: 1 x DN
- Display: 4-digit alphanumeric
- 6 green LEDs for units
- 2 yellow LEDs for switch status
Electrical and Communication
- Supply voltage: 18 to 30 V DC (SELV / PELV)
- Current consumption: 95 mA at 24 V
- Protection class: III, with reverse polarity protection
- Power-on delay: 5 s
- Digital outputs: 2 x PNP/NPN, NO/NC configurable
- Voltage drop: 2 V max
- Continuous current: 200 mA
- Analog output:
- 4 to 20 mA, load 500 Ω max
- 0 to 10 V, load 2000 Ω min
- Pulse output: For flow rate
- Input: Counter reset
- Short-circuit and overload protection: Yes, pulsed type
- Connector: M12, 4-pin, coding A, gold-plated contacts
- IO-Link:
- Revision 1.1, COM2 (38.4 kBaud)
- Standard: IEC 61131-9
- SIO mode: yes
- Master port type: A
- Minimum cycle time: 5 ms
- DeviceID: 569
Environment and Durability
- Operating temperature: -10 to 60 °C
- Storage temperature: -25 to 80 °C
- Protection rating: IP 67
- EMC: DIN EN 60947-5-9
- Shock: DIN IEC 68-2-27, 20 g for 11 ms
- Vibration: DIN IEC 68-2-6, 5 g from 10 to 2000 Hz
- MTTF: 145 years
- Pressure Equipment Directive: Good engineering practice
- Suitable for fluid group 2
- Group 1 fluids on request
- Approvals: CE, UKCA, UL, CRN, DNV, KTW/W270, Reg (EU) 1935/2004
Physical Data
- Dimensions: 110 x 54 x 54 mm
- Flow body: Cylindrical, Ø 54 mm, length 110 mm
- Weight: 548 g
Best Fit Devices and Applications
- Water treatment lines: Filters, dosing skids, and rinse stations
- Cooling circuits: Machine tools, laser systems, and molds
- Food and beverage units: KTW/W270 approval supports potable water contact
- Process skids: Flow plus temperature monitoring on one device
- Pump protection: Dry-run detection with switch and analog outputs
- IO-Link networks: Direct parameter access from the PLC
- Marine and offshore: DNV approval suits shipboard systems
FAQ
Q: What liquid can this flow meter handle?
A: It works with conductive liquids. Water and water-based media are the main target. The liquid needs at least 20 µS/cm conductivity.
Q: How much straight pipe is needed before the sensor?
A: Allow 3 x DN on the inlet side. Allow 1 x DN on the outlet side. Short runs cause swirl and unstable readings.
Q: Can I read flow and temperature at the same time?
A: Yes. The unit tracks flow and medium temperature together. The 4-digit display shows either value. IO-Link sends both to the controller.
Q: What causes a zero-flow reading to drift?
A: Air bubbles are the most common cause. Trapped gas in the pipe disturbs the magnetic field. Mount the sensor in a full pipe and bleed the line first.
Q: How do I set the analog span for my PLC?
A: Set ASP for the low end and AEP for the high end. Choose a span inside 0 to 25 l/min. Match the load to 500 Ω for current or 2000 Ω for voltage.
Q: Is a separate temperature probe needed?
A: Usually no. The built-in temperature channel covers -20 to 80 °C. Accuracy stays within ±2.5 K when flow exceeds 1 l/min.