Product details
Product Overview
- TWDLCAA10DRF is a compact base controller from Schneider Electric Twido series.
- It runs on 100–240 V AC supply and supports expansion modules.
- This unit offers 6 digital inputs (24 V DC) and 4 relay outputs.
- It is a complete, ready‑to‑use PLC for small machines and simple automation.
Key Technical Data
- Brand: Schneider Electric
- Model: TWDLCAA10DRF
- Series: Twido
- Type: Compact base controller (expandable)
- Supply voltage: 100…240 V AC (85…264 V limits)
- Discrete I/O: 6 inputs (24 V DC) + 4 relay outputs
- Input logic: Sink or source
- Input current: 11 mA (I0.0–I0.1), 7 mA (I0.2–I0.5)
- Output load: 2 A per relay (resistive/inductive)
- Program memory: 700 instructions
- Execution speed: 1 ms per 1000 instructions
- Internal RAM: 128 counters, 64 timers, 3000 words
- Counting inputs: 1 at 20 kHz (32‑bit), 3 at 5 kHz (16‑bit)
- Backup: Internal lithium battery (30 days, 10‑year life)
- Serial link: RS485 (Modbus RTU/ASCII), 38.4 kbps
- Power consumption: 20 VA at 100 V, 30 VA at 264 V
- Sensor supply: 0.25 A at 24 V DC
Performance & Accuracy
- Filter time: 35 µs + programmed (ON), 45 µs + programmed (OFF).
- Isolation: 1500 Vrms between channels and logic.
- Insulation resistance: >10 MΩ at 500 V.
- Relay durability: 20 million mechanical, 100,000 electrical cycles.
- Ambient temperature: 0…55 °C operation, -25…70 °C storage.
- Protection: IP20, internal fuse for power.
Installation & Wiring
- Mount on 35 mm DIN rail or panel (fixing kit optional).
- Use non‑removable screw terminal blocks for I/O connections.
- Connect 100–240 V AC supply to L and N terminals.
- Ground the GND terminal for safety.
- Wire inputs to COM_NEG or COM_POS (sink/source).
- Output relays: connect load to common (COM) and normally‑open (NO) contacts.
Compatibility & Expandability
- Accepts memory cartridge or real‑time clock cartridge.
- Works with all Twido expansion I/O modules.
- RS485 port supports Modbus master/slave and ASCII.
- Communicates with HMIs, VFDs, and sensors.
Applications & Suitable Equipment
- Small conveyors – start/stop and belt speed control.
- Packaging machines – counting, filling, and sealing.
- HVAC systems – fan, damper, and valve control.
- Pumping stations – level control and alarm handling.
- Lighting control panels – automatic ON/OFF and dimming.
Manager’s Insight
- “The TWDLCAA10DRF is a reliable choice for small control tasks. Its built‑in power supply saves panel space. Use the counting inputs for high‑speed signals like encoders. Always check the relay load – 2 A max per output.”
- – Product Manager, Powergear X
Expert Review
- “This controller offers great value. The RS485 port makes it easy to connect to Modbus networks. Programming is simple with TwidoSoft. We recommend it for OEMs who need a compact, expandable PLC.”
- – Senior Automation Engineer, Powergear X
Certifications & Standards
- CE, UL, CSA certified – meets global safety requirements.
- IP20 – suitable for control cabinet installation.
- 1500 V dielectric strength – safe isolation.
- Vibration and shock resistant (DIN rail or panel mount).
What’s in the Box
- 1x TWDLCAA10DRF controller.
- 1x set of screw terminal blocks (non‑removable).
- Quick start guide (English).
- No programming cable included – order separately.
Warranty & Shipping
- Warranty: 12 months from delivery.
- Dispatch: 12–24 hours after order.
- Carriers: FedEx, UPS, DHL – tracking provided.
Frequently Asked Questions (FAQ)
- Can this controller be expanded?
Yes, you can add up to 4 expansion modules (digital or analog). - Does it have a real‑time clock?
No, but you can add a clock cartridge (sold separately) for time‑based tasks. - What is the maximum counting frequency?
One input handles 20 kHz (32‑bit), and three inputs handle 5 kHz (16‑bit). - How do I connect a Modbus device?
Use the RS485 mini‑DIN port with a suitable adapter. Set the protocol in TwidoSoft. - What happens if power fails?
Internal battery keeps data for 30 days. It recharges in 10 hours when power returns. - Can I use it with 24 V DC sensors?
Yes, the built‑in 24 V DC output provides 0.25 A for sensors. - Is programming difficult?
No – use TwidoSoft (free) or EcoStruxure Machine Expert. It uses ladder logic or FBD. - What is the relay switching frequency?
Keep below 30 cycles per minute for inductive loads to extend contact life.
Selection Guide
- Count your I/O points – if you need more, choose this expandable base.
- For high‑speed counting, use the 20 kHz input (I0.0).
- If you need analog signals, add an analog expansion module.
- For time‑stamping, order the real‑time clock cartridge.
- Always verify the total current of your outputs – relay contacts share a common.
Compare with Similar Models
- TWDLCAA10DRF (this model) – 6 inputs, 4 relays, expandable.
- TWDLCDA10DRF – similar but with 24 V DC supply.
- TWDLCAA24DRF – more I/O (14 inputs / 10 outputs).
- TWDLMDA20DRT – analog + digital combo.
For inquiries:
sales@powergearx.com |
+86 180 3005 825
Copyright © 2026 Powergear X Automation Limited. All rights reserved.