Product details
Product at a Glance
- PSTX840-600-70 – ABB softstarter for heavy motors
- Rated current: 840 A (in-line) / 1455 A (inside delta)
- Voltage range: 208…600 V AC, 50/60 Hz
- Control supply: 100…250 V AC or 24 V DC
- Built-in bypass saves energy and simplifies wiring
- Detachable graphic display (IP66, outdoor rated)
Key Technical Specifications
- Brand: ABB – PSTX series
- Model: PSTX840-600-70 (ID: 1SFA898119R7000)
- In-line power: 450 kW (400 V) · 600 kW (500 V)
- Inside-delta power: 800 kW (400 V) · 1000 kW (500 V)
- Starting capacity: 4×Ie for 10 seconds
- Current limit: 1.5…7.5×Ie
- Ramp time: 1…120 seconds
- Initial voltage: 10…99 V (adjustable)
- Analog outputs: 0‑10 V, 0‑20 mA, 4‑20 mA
- Communication: Modbus RTU/TCP, Profibus, Profinet, Ethernet/IP, DeviceNet, CANopen, EtherCAT, BACnet
Protection & Diagnostics
- Built-in electronic overload protection
- Earth fault, phase reversal, under/over voltage protection
- Locked rotor, current imbalance, and underload protection
- PT‑100 and PTC inputs for motor thermal monitoring
- Event log with real‑time clock
- LED indicators: Ready (green), Running (green), Protection (yellow), Fault (red)
Advanced Functions
- Torque control soft start/stop
- Kick start, pump cleaning, and emergency mode
- Jog (forward/reverse) with slow speed
- Dynamic brake and stand‑still brake
- Motor heating and pre‑start function
- Limp mode – two‑phase control if one thyristor fails
- Auto phase sequence detection and voltage sag detection
Environmental & Installation
- Operating temperature: -25…+60 °C
- Storage temperature: -40…+70 °C
- Protection degree: IP00 (main terminals)
- Main terminals: copper bars, torque 45 N·m
- Control terminals: rigid 2.5 mm²
- Dimensions: 435×493×369 mm · Weight: 46.5 kg
Certifications & Compliance
- CE, CCC, CQC, DNV certified
- RoHS II, REACH, TSCA compliant
- ETIM 9: EC000640 · eClass V11.0: 27370907
- WEEE category 5 (B2B)
Commissioning & Maintenance
- Full graphic display for easy setup – no PC needed
- Quick‑start wizard guides parameter configuration
- Fieldbus plug‑and‑play with optional ANYBUS modules
- Diagnostic menu shows thyristor runtime and event history
- All terminals are clearly marked for fast wiring
What’s Included
- PSTX840-600-70 softstarter unit
- Detachable graphic display (IP66)
- Mounting hardware and terminal bars
- Quick start guide and installation manual (digital)
Warranty & Delivery
- 12‑month warranty against material or workmanship defects
- Shipping: 12‑24 hours dispatch on business days
- Carriers: FedEx, UPS, DHL – express worldwide
Expert Review – Engineer’s Take
- “This softstarter handles 800 kW inside‑delta without breaking a sweat. The torque ramp and pump cleaning are lifesavers for water applications. Easy to commission via the graphic display.” – Senior Field Application Engineer
Manager’s Insight
- “PSTX840 offers the best price‑to‑power ratio in its class. The communication flexibility and built‑in bypass reduce panel complexity. A reliable choice for plant upgrades.” – Product Line Manager
Typical Applications
- Large centrifugal pumps and deep‑well pumps
- Heavy‑duty fans, blowers, and compressors
- Conveyors, crushers, and mills
- Mixers, extruders, and industrial agitators
- Emergency/fire pump systems
Frequently Asked Questions (FAQ)
- Q: What is the maximum starting current for this model?
A: 4 times the rated current (4×840 A) for 10 seconds. - Q: Can I use PSTX840 for inside‑delta connection?
A: Yes. The switchable inside‑delta mode increases output to 1455 A. - Q: Does it support Ethernet communication out of the box?
A: It comes with Modbus RTU; optional ANYBUS modules add Profinet, Ethernet/IP, etc. - Q: How do I monitor motor temperature?
A: Connect PT‑100 or PTC sensors directly to the built‑in inputs. - Q: What happens if the display fails?
A: The unit continues to run with the last settings; you can replace the display without powering down.
Practical Field Tips
- Tip 1: For pump cleaning, set the ramp time to 5‑8 seconds to avoid water hammer.
- Tip 2: Use the torque control mode for conveyors – it reduces belt stress.
- Tip 3: Enable the emergency mode for fire pumps – it overrides all protections to keep the motor running.
Selection Guide – Choosing the Right PSTX
- Choose PSTX840-600-70 for motors up to 450 kW (in‑line) or 800 kW (inside‑delta).
- For lower currents, consider PSTX570 (570 A) or PSTX370 (370 A).
- Check ambient temperature: this model works from -25 °C to +60 °C.
- Ensure main circuit voltage matches 208…600 V AC, 50/60 Hz.
- Select the appropriate Fieldbus module for your PLC system.
Comparison with Similar Models
- PSTB370-600-70 – 370 A, 200 kW in‑line, built‑in bypass
- PSTX570-600-70 – 570 A, 315 kW in‑line, same advanced features
- PSTX1250-600-70 – 1250 A, 700 kW in‑line, for the largest motors
Ordering & Support
- Minimum order: 1 piece
- Customs tariff: 85371091
- EAN: 7320500510421
- For quotes or technical help:
- 📧 sales@powergearx.com
- 📞 +86 18030005825 (WhatsApp)
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
















There are no reviews yet.