Product details
以下是可直接粘贴到 Shopify 产品内容编辑器的 HTML 片段(不含 html/body 等标签,无 CSS、无 div、无表格、无分割线、无星号):
Product Overview
MDX91A-0750-503-4-T00 is a book-style multi-axis inverter from SEW-EURODRIVE. It belongs to the MOVIDRIVE modular MDX91A series. The unit delivers 75.0 A rated output at 4 kHz PWM. It connects directly to a 3-phase AC line. Frame size 5 supports 4-quadrant operation. An integrated DC 24 V auxiliary supply (80 W) is included. A brake chopper is built in. The drive suits control-cabinet multi-axis systems in industrial automation.
Key Technical Data
- Brand: SEW-EURODRIVE
- Model: MDX91A-0750-503-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Frame size: 5
- Rated output current: 75.0 A at 4 kHz PWM
- Nominal line current: 67.5 A
- Supply voltage: 3 x AC 380-500 V, 50-60 Hz
- Line frequency tolerance: 50-60 Hz, plus or minus 5%
- Recommended motor power (ASM): 37 kW
- Apparent output power S_N: 46.8 kVA
- Overload capacity: 200% of I_N for 3 s at 4 kHz PWM
- Continuous output at 0 Hz: I_N x 0.9
- PWM frequency: 4, 8, 16 kHz, adjustable
- Max output frequency: U/f 599 Hz; VFCplus 250 Hz; CFC 500 Hz; ELSM 500 Hz
- Nominal DC link voltage: DC 560 V
- Brake chopper continuous power: 46.8 kW
- Brake chopper peak power: 200% x S_N
- Power section nominal loss: 760 W
- Control modes: U/f, VFCplus, CFC, ELSM
- Weight: 12.1 kg
Control Performance
- Resolution and response: field-oriented CFC and ELSM control give fast torque response for dynamic loads.
- Speed range: output frequency up to 599 Hz in U/f mode.
- Linearity: stable current control across the full 4 kHz PWM range.
- Interference immunity: basic EMC filtering is integrated.
- Measurement accuracy: consistent current regulation at 0 Hz with I_N x 0.9.
Environmental Tolerance
- Operating temperature: 0 to +40 °C without derating
- Operating temperature with derating: +40 to +60 °C
- Storage temperature: -25 to +70 °C, non-condensing (EN 60721-3-1 class 1K2)
- Transport temperature: -25 to +70 °C, non-condensing (EN 60721-3-2 class 2K3)
- Relative humidity: non-condensing (EN 60721-3-3 class 3K3)
- Protection rating: IP10; IP20 with optional plastic terminal covers
- Pollution class: 2 (IEC 60664-1); overvoltage category III
- Installation altitude: up to 1000 m without restriction
- Altitude derating: 1% per 100 m from 1000 to 3800 m
Communication and Compatibility
- Built-in system bus: EtherCAT with CiA402 profile
- Fieldbus option cards: /CFN21A PROFINET IO, /DFE32B EtherNet/IP, /DFI11B PROFIBUS DPV1
- Expansion cards: /CES11A multi-encoder, /CID21A encoder interface, /CIO21A I/O expansion
- Safety option: /CS..A MOVISAFE card
- Coating option: /L conformal-coated PCB
- Platform fit: part of the MOVI-C platform and MOVIDRIVE system
Installation Guide
- Mount the book-style unit vertically inside a control cabinet.
- Keep the specified clearances for cooling air.
- Connect line and motor cables to the M8 screw terminals.
- Wire the DC 24 V auxiliary supply, or add an external supply.
- Fit a braking resistor if the application needs braking energy.
- Add plastic terminal covers to reach IP20.
- Follow the dimension drawings in product manual section 2.7.
Commissioning and Maintenance
- Set the control mode to match the motor type.
- Run the startup routine for CFC or ELSM motors.
- Check current limits and overload settings.
- Keep firmware and option cards aligned with the manual.
- Clean cooling paths at regular service intervals.
- Check screw terminals for tightness during service.
Certifications and Standards
- Pollution class 2 per IEC 60664-1
- Overvoltage category III
- Climate classes 1K2, 2K3 and 3K3 per EN 60721
- Basic EMC interference suppression integrated
- Current manual active; last verified 2026-09
Packing List
- 1 x MDX91A-0750-503-4-T00 inverter
- 1 x product documentation set
- Terminal covers only if ordered
- Braking resistor and option cards sold separately
FAQ
Q: Can this drive run a synchronous motor?
A: Yes. ELSM mode supports extended synchronous motor control.
Q: What is the rated output current?
A: 75.0 A at 4 kHz PWM, with 200% overload for 3 s.
Q: Does it include a brake chopper?
A: Yes. A chopper is built in. Add a BR.. resistor if needed.
Q: Which fieldbuses are supported?
A: EtherCAT is built in. PROFINET, EtherNet/IP and PROFIBUS need option cards.
Q: How much derating applies above 40 °C?
A: The drive derates from +40 to +60 °C. Check the manual curve.
Q: Can I use it above 1000 m altitude?
A: Yes. Derate I_N by 1% per 100 m up to 3800 m.
Q: What protection rating does it ship with?
A: IP10 standard. Add plastic covers for IP20.
Q: Is the DC 24 V supply enough for the control board?
A: The 80 W supply covers control needs. Add an external supply for heavy loads.
Q: How do I pick a braking resistor?
A: Use the resistor selection table. R_BRmin is not a single published value.
Q: What is the typical startup time on site?
A: Most users finish basic startup in under an hour with the manual.















There are no reviews yet.