Product details
Product Description
- Honeywell XNX-UTAE-NNNNN is a universal gas transmitter for hazardous areas.
- It uses an electrochemical (EC) cartridge for toxic or oxygen gas detection.
- Output: 4-20 mA with HART (sink/source/isolated). Accuracy: ±1% full scale.
- Rugged painted aluminum alloy housing. IP66 / NEMA 4X rated.
- Operates from -40°C to 65°C, 0–99% RH non-condensing.
- Power: 16–32 VDC, max 6.2 W (EC). Weight: 2.8 kg (6.2 lbs).
- Cable entry: 5 x 3/4″ NPT. Mounting: surface, pipe, or ceiling.
- No local HART interface. No extra relays.
Technical Specifications
- Brand: Honeywell
- Model: XNX-UTAE-NNNNN
- Series: XNX Universal Transmitters
- Sensor Type: Electrochemical (EC) for toxic/O₂ cartridges
- Output Signal: 4-20 mA with HART (selectable sink/source/isolated)
- Accuracy: ±1% of full scale
- Voltage: 16 to 32 VDC
- Power Consumption: 6.2 W max (EC)
- Operating Temperature: -40°C to 65°C
- Humidity: 0–99% RH (non-condensing)
- Enclosure Rating: IP66 (NEMA 4X)
- Material: Painted aluminum alloy
- Cable Entry: 5 x 3/4″ NPT
- Mounting: Surface mount with lugs (pipe/ceiling optional)
- Local HART: Not installed
- Relay Output: None (4-20mA/HART only)
- Weight: 2.8 kg (6.2 lbs)
Key Features & Benefits
- Measurement Range: Depends on MPD sensor cartridge (order separately).
- Frequency Response: Fast response for toxic and oxygen gases.
- Sensitivity: High sensitivity with low drift.
- Linearity: Excellent linearity over full range.
- Resolution: Fine resolution for precise readings.
- Temperature Range: -40°C to 65°C for extreme environments.
- Environmental Tolerance: IP66, NEMA 4X, 0–99% RH.
- Immunity: Built-in RFI/EMI protection.
Installation Guide
- Surface mount via integral lugs. Optional pipe or ceiling mount kits available.
- Use 5 x 3/4″ NPT cable entries for wiring.
- Connect 16–32 VDC power supply. Observe polarity.
- Set 4-20 mA output as sink, source, or isolated via DIP switches.
- Mount the sensor cartridge (order separately) into the EC interface.
- Ensure proper sealing to maintain IP66 rating.
Commissioning & Maintenance
- Simple zero and span calibration with magnetic wand (no need to open housing).
- Automatic sensor diagnostics for easy troubleshooting.
- Routine maintenance: check sensor life and clean the enclosure.
- HART communication allows remote configuration and monitoring.
- Firmware updates via HART (if supported).
Compatibility
- Works with all XNX toxic and oxygen electrochemical cartridges.
- Compatible with standard 4-20 mA control systems.
- HART protocol enables integration with asset management software.
- Approved for use with UL/CSA certified systems.
Certifications
- UL / CSA approved for hazardous locations.
- IP66 (NEMA 4X) – dust-tight and weather-resistant.
- CE marked for European compliance.
- ATEX / IECEx optional (verify with factory).
Package Contents
- 1 x XNX-UTAE-NNNNN transmitter unit
- 1 x Mounting hardware kit
- 1 x Quick start guide
- Sensor cartridge not included – order separately by gas type.
- Warranty card (12 months from date of purchase).
Warranty & Shipping
- 12-month warranty against manufacturing defects.
- Ship within 12–24 hours after order confirmation.
- Carriers: FedEx, UPS, DHL – worldwide express.
- Tracking number provided within 24 hours.
Expert Review
“The XNX-UTAE-NNNNN sets a benchmark for reliability. Its rugged build and wide temperature range make it ideal for oil & gas, chemical plants, and wastewater facilities. The magnetic interface simplifies calibration, and HART integration is seamless. A solid choice for safety managers.” – Powergear X Engineering Team
Manager’s Insight
“From a procurement standpoint, this transmitter offers excellent value. The modular design reduces spare parts inventory, and the 12-month warranty gives peace of mind. The 12–24 hour shipping via FedEx/UPS/DHL ensures you get it fast.” – Supply Chain Manager
Applications & Suitable Devices
- Oil refineries, petrochemical plants
- Chemical storage and processing
- Water and wastewater treatment
- Mining and metal processing
- Pharmaceutical manufacturing
- Food and beverage industry (CO₂, O₂ monitoring)
- Compatible with PLCs, DCS, SCADA, and HART handheld communicators.
Frequently Asked Questions
- What gases can this transmitter detect?
- It detects any toxic gas or oxygen using the corresponding MPD sensor cartridge (ordered separately).
- Is the sensor included?
- No. The XNX-UTAE-NNNNN comes without a sensor. You must purchase the correct electrochemical cartridge for your target gas.
- Can I use this in a Class I Division 1 area?
- Yes, it is UL/CSA approved for hazardous locations (verify specific certificate).
- How do I calibrate the transmitter?
- Use the magnetic wand to enter calibration mode without opening the housing. Follow the menu prompts.
- What is the maximum cable length for 4-20 mA?
- Up to 1000 meters (depending on cable gauge and power supply).
- Does it support Modbus?
- No. It supports 4-20 mA with HART only. Modbus requires additional gateway.
Buyer’s Guide & Selection Advice
- Choose the correct sensor cartridge for your specific gas (e.g., H₂S, CO, Cl₂, O₂).
- Verify power supply: 16–32 VDC, 6.2 W max.
- Select mounting option: surface, pipe, or ceiling (accessories sold separately).
- Confirm cable entry type – 5 x 3/4″ NPT is standard.
- For HART communication, ensure your control system supports HART.
- If you need relays or local display, consider other XNX variants.
For inquiries, contact our sales team:
sales@powergearx.com |
+86 18030005825 (WhatsApp)
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
















There are no reviews yet.