  • Honeywell XNX-UTAE-NNNNN is a universal gas transmitter for hazardous areas.
  • It uses an electrochemical (EC) cartridge for toxic or oxygen gas detection.
  • Output: 4-20 mA with HART (sink/source/isolated). Accuracy: ±1% full scale.
  • Rugged painted aluminum alloy housing. IP66 / NEMA 4X rated.
  • Operates from -40°C to 65°C, 0–99% RH non-condensing.
  • Power: 16–32 VDC, max 6.2 W (EC). Weight: 2.8 kg (6.2 lbs).
  • Cable entry: 5 x 3/4″ NPT. Mounting: surface, pipe, or ceiling.
  • No local HART interface. No extra relays.

Technical Specifications

  • Brand: Honeywell
  • Model: XNX-UTAE-NNNNN
  • Series: XNX Universal Transmitters
  • Sensor Type: Electrochemical (EC) for toxic/O₂ cartridges
  • Output Signal: 4-20 mA with HART (selectable sink/source/isolated)
  • Accuracy: ±1% of full scale
  • Voltage: 16 to 32 VDC
  • Power Consumption: 6.2 W max (EC)
  • Operating Temperature: -40°C to 65°C
  • Humidity: 0–99% RH (non-condensing)
  • Enclosure Rating: IP66 (NEMA 4X)
  • Material: Painted aluminum alloy
  • Cable Entry: 5 x 3/4″ NPT
  • Mounting: Surface mount with lugs (pipe/ceiling optional)
  • Local HART: Not installed
  • Relay Output: None (4-20mA/HART only)
  • Weight: 2.8 kg (6.2 lbs)

Key Features & Benefits

  • Measurement Range: Depends on MPD sensor cartridge (order separately).
  • Frequency Response: Fast response for toxic and oxygen gases.
  • Sensitivity: High sensitivity with low drift.
  • Linearity: Excellent linearity over full range.
  • Resolution: Fine resolution for precise readings.
  • Temperature Range: -40°C to 65°C for extreme environments.
  • Environmental Tolerance: IP66, NEMA 4X, 0–99% RH.
  • Immunity: Built-in RFI/EMI protection.

Installation Guide

  • Surface mount via integral lugs. Optional pipe or ceiling mount kits available.
  • Use 5 x 3/4″ NPT cable entries for wiring.
  • Connect 16–32 VDC power supply. Observe polarity.
  • Set 4-20 mA output as sink, source, or isolated via DIP switches.
  • Mount the sensor cartridge (order separately) into the EC interface.
  • Ensure proper sealing to maintain IP66 rating.

Commissioning & Maintenance

  • Simple zero and span calibration with magnetic wand (no need to open housing).
  • Automatic sensor diagnostics for easy troubleshooting.
  • Routine maintenance: check sensor life and clean the enclosure.
  • HART communication allows remote configuration and monitoring.
  • Firmware updates via HART (if supported).

Compatibility

  • Works with all XNX toxic and oxygen electrochemical cartridges.
  • Compatible with standard 4-20 mA control systems.
  • HART protocol enables integration with asset management software.
  • Approved for use with UL/CSA certified systems.

Certifications

  • UL / CSA approved for hazardous locations.
  • IP66 (NEMA 4X) – dust-tight and weather-resistant.
  • CE marked for European compliance.
  • ATEX / IECEx optional (verify with factory).

Package Contents

  • 1 x XNX-UTAE-NNNNN transmitter unit
  • 1 x Mounting hardware kit
  • 1 x Quick start guide
  • Sensor cartridge not included – order separately by gas type.
  • Warranty card (12 months from date of purchase).

Warranty & Shipping

  • 12-month warranty against manufacturing defects.
  • Ship within 12–24 hours after order confirmation.
  • Carriers: FedEx, UPS, DHL – worldwide express.
  • Tracking number provided within 24 hours.

Expert Review

“The XNX-UTAE-NNNNN sets a benchmark for reliability. Its rugged build and wide temperature range make it ideal for oil & gas, chemical plants, and wastewater facilities. The magnetic interface simplifies calibration, and HART integration is seamless. A solid choice for safety managers.” – Powergear X Engineering Team

Manager’s Insight

“From a procurement standpoint, this transmitter offers excellent value. The modular design reduces spare parts inventory, and the 12-month warranty gives peace of mind. The 12–24 hour shipping via FedEx/UPS/DHL ensures you get it fast.” – Supply Chain Manager

Applications & Suitable Devices

  • Oil refineries, petrochemical plants
  • Chemical storage and processing
  • Water and wastewater treatment
  • Mining and metal processing
  • Pharmaceutical manufacturing
  • Food and beverage industry (CO₂, O₂ monitoring)
  • Compatible with PLCs, DCS, SCADA, and HART handheld communicators.

Frequently Asked Questions

  • What gases can this transmitter detect?
    • It detects any toxic gas or oxygen using the corresponding MPD sensor cartridge (ordered separately).
  • Is the sensor included?
    • No. The XNX-UTAE-NNNNN comes without a sensor. You must purchase the correct electrochemical cartridge for your target gas.
  • Can I use this in a Class I Division 1 area?
    • Yes, it is UL/CSA approved for hazardous locations (verify specific certificate).
  • How do I calibrate the transmitter?
    • Use the magnetic wand to enter calibration mode without opening the housing. Follow the menu prompts.
  • What is the maximum cable length for 4-20 mA?
    • Up to 1000 meters (depending on cable gauge and power supply).
  • Does it support Modbus?
    • No. It supports 4-20 mA with HART only. Modbus requires additional gateway.

Buyer’s Guide & Selection Advice

  • Choose the correct sensor cartridge for your specific gas (e.g., H₂S, CO, Cl₂, O₂).
  • Verify power supply: 16–32 VDC, 6.2 W max.
  • Select mounting option: surface, pipe, or ceiling (accessories sold separately).
  • Confirm cable entry type – 5 x 3/4″ NPT is standard.
  • For HART communication, ensure your control system supports HART.
  • If you need relays or local display, consider other XNX variants.

For inquiries, contact our sales team:
sales@powergearx.com  |
+86 18030005825 (WhatsApp)

Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/

Specifications

  • BrandHoneywell
  • Part NumberXNX-UTAE-NNNNN
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “Honeywell XNX-UTAE-NNNNN Universal Gas Transmitter, 4-20mA HART”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart