XNX-AMAV-NHNNN – Universal Transmitter (Sensor Ready)
- Honeywell transmitter without a pre‑installed sensor
- Works with milli‑Volt sensors (MPD, Sensepoint, Model 705)
- HART® over 4‑20 mA plus local HART® port
- ATEX / IECEx approved for hazardous zones
Technical Specifications
- Power & signals
- Standard: HART over 3‑wire 4‑20 mA (sink, source, or isolated)
- Optional: Modbus RS‑485 or FOUNDATION Fieldbus
- 20 mA loop compliant with NAMUR NE43
- Communication options
- Relays: 3 form C (2 alarm, 1 fault), 5A @ 250 VAC / 24 VDC
- Remote reset for alarm silencing
- Modbus RTU over RS‑485 (baud 1200‑38400, default 19200)
- FOUNDATION Fieldbus H1 (31.25 kbit/s)
- Note: relays, Modbus, and Fieldbus are mutually exclusive
- Enclosure & mounting
- Marine‑grade aluminium or SS316
- 5‑coat painted finish
- Integral mounting lugs for wall or pipe mounting
- Optional wall/ceiling bracket
- Cable ports
- 5 ports (2 right, 2 left, 1 bottom)
- Choose 3/4″ NPT or M25
- User interface
- Custom backlit LCD
- Magnetic wand operation (no opening required)
- Optional HART handheld via IS port
- Environmental ratings
- IP66 (dust‑tight, water‑resistant)
- Operating temp: ‑40 to +65 °C (transmitter & MPD‑CB1)
- MPD‑I models: ‑20 to +50 °C
- Storage: ‑40 to +65 °C
- Humidity: 0‑99% RH non‑condensing
- Pressure: 80‑120 kPa
- Air speed: 0‑6 m/s
- Physical
- Dimensions: 159 x 197 x 113.8 mm
- Weight: 2.27 kg (aluminium) / 5 kg (SS316)
- RTC battery backup
- 3 years unpowered at storage temperature
Expert Review
- “The XNX‑AMAV‑NHNNN is a flexible, sensor‑ready platform.”
- “Its multi‑protocol support (HART, Modbus, Fieldbus) covers all plant needs.”
- “The magnetic wand interface makes calibration safe and easy.”
- “IP66 and wide temperature range ensure dependable outdoor use.”
Manager’s Insight
- “Buy this transmitter if you need to change sensors later.”
- “It works with many mV sensors – MPD, Sensepoint, Model 705.”
- “The relay option gives you direct alarm control.”
- “We back it with a 12‑month warranty and ship within 12‑24 hours via FedEx, UPS, or DHL.”
Applications & Compatible Sensors
- Typical uses
- Oil & gas terminals
- Chemical processing plants
- Refineries and storage facilities
- Wastewater treatment (digester gas)
- Compatible sensors (sold separately)
- MPD series (toxic / combustible)
- Sensepoint HT (high‑temperature)
- Model 705 (PPM / LEL)
Frequently Asked Questions (FAQ)
- Does this unit come with a sensor?
- No. It is a transmitter only – you need to buy a separate mV sensor.
- What communication protocols are supported?
- Standard HART, optional Modbus RTU, or FOUNDATION Fieldbus.
- Can I add relays for alarm control?
- Yes, but only if you choose the relay option instead of Modbus or Fieldbus.
- What is the operating temperature range?
- Transmitter: ‑40 to +65 °C. Check the sensor’s data sheet for its limit.
- How do I configure it without opening the enclosure?
- Use the magnetic wand on the backlit LCD – no tools needed.
- What is the warranty and shipping time?
- 12‑month warranty. We dispatch within 12‑24 hours via FedEx, UPS, or DHL.
Selection Guide
- Choose XNX‑AMAV‑NHNNN if you need a versatile transmitter for multiple sensor types.
- For propane / hydrocarbon LEL, see XNX‑AMAV‑NNIF1 (comes with IR sensor).
- For CO₂ 0‑5% vol, pick XNX‑AMAV‑NNIC1.
- For stainless steel housing, order the SS316 version.