Product details
Product Snapshot
- DS200TCTGG1AEE is a turbine trip board from General Electric.
- It belongs to the Speedtronic Mark V series.
- It handles simplex trip relay logic for gas turbines.
- It is a service spare for Mark V control systems.
Hardware Tree
- DS200TCTGG1AEE
- Function
- Turbine trip board (simplex trip)
- Built for the Mark V platform
- Source: GEH-6153 and supplier visual check
- Relays
- 21 plug-in relays
- Electromechanical type; handle with care
- Connectors
- 3 x 50-pin: JLY, JLX, JLZ
- 2 x 12-pin: JN, JM
- Circuits
- ETR relay
- PTR relay
- Generator breaker close
- Manual trip
- External trip
- Operation
- Works with the <P> protective module
- Each module runs on its own logic
- Build
- Normal PCB coating
- A-rated functional revision
- Function
Electrical and Communication
- Power: Mark V system supply
- Backplane: Mark V COREBUS/VME backplane
- Role: Trip signals route through the backplane
Environment (Cabinet Level)
- Panel ambient: 0 to +45 °C continuous
- Panel humidity: 5 to 95% RH, non-condensing
- Enclosure: NEMA 1 / IP20
- These values apply to the host cabinet. They are not board nameplate data.
Documents
- Manual: GEH-6153 Mark V Function Manual (WINSYS Edition)
- Check: Supplier visual inspection report
Application Fit
- Gas turbine trip circuits
- Mark V speed and protection panels
- Power plant maintenance and outage work
- Spare stocking for legacy turbines
Compare With Other Models
- DS200TCTGG1A — earlier revision of the same trip board family.
- DS200TCTGG1AEC — close cousin; check revision letter before swapping.
- DS200TCTG — base trip board line for Mark V.
- DS200DTBBG1A — discrete termination board; pairs in trip paths.
- DS200PTBAG1A — protection terminal board used with trip logic.
- Always match the full part number and revision letter.
Expert Review
- The DS200TCTGG1AEE is a proven Mark V trip board.
- It uses 21 plug-in relays. That gives clear trip paths.
- Simplex design keeps wiring simple.
- Relay contacts wear over time. Plan checks in every outage.
- Keep one spare on site for old turbines.
Manager’s Insight
- Mark V fleets are aging. Trip boards fail at relay level.
- Buy the exact revision. Small letter changes can block a swap.
- Store boards in anti-static bags. Relays are fragile.
- Fast shipping matters more than small price gaps in a shutdown.
FAQ
- Q: How do I know the board fits my rack?
- A: Send the full code and revision letter from your old board. We check it for you.
- Q: What fails most on this type?
- A: Plug-in relays fail first. Burned contacts and weak coils are common.
- Q: Can I test it before shipping out?
- A: Ask us for the test report and photos. We share what the supplier provides.
- Q: What is your warranty and lead time?
- A: 12-month warranty. Orders ship in 12-24 hours by FedEx, UPS, DHL.
- Q: What should I check before buying a used board?
- A: Check relay marks, coating condition, and revision letter. Ask for clear close-up photos.
Contact
- Email: sales@powergearx.com
- WhatsApp: +86 18030005825
- Send your old board photo. We reply fast.
Copyright
- Copyright © 2026 Powergear X Automation Limited. All rights reserved.
- Original Source: https://www.powergearx.com/