FX1S-20MR-001 – Mitsubishi Electric Compact PLC

20 I/O relay-type controller. 24V DC, high-speed counters, UL/CE certified. Built for OEM & small automation.

📋 Product Description – FX1S Series

  • ├─ Mitsubishi FX1S-20MR-001 – all-in-one PLC main unit
  • │ ├─ Total I/O: 20 points (12 digital inputs + 8 relay outputs)
  • │ ├─ Power supply: 24V DC ±10% (sink/source selectable)
  • │ ├─ Output type: Relay – 2A per point, isolated contacts
  • │ └─ Program memory: 2,000 steps EEPROM, no battery needed
  • ├─ Compact footprint for tight panels
  • │ ├─ Dimensions: 75 × 90 × 75 mm (W×H×D)
  • │ └─ Weight: 0.4 kg – easy DIN rail or direct mount
  • ├─ Built-in high-speed counters & timers
  • │ ├─ 2 high-speed counters (60kHz / 10kHz)
  • │ └─ 1 ms timer resolution for precise control
  • └─ Compatible with GX Developer and GX Works2 software

⚙️ Technical Specifications

  • ├─ Brand: Mitsubishi Electric
  • ├─ Model / Catalog No: FX1S-20MR-001
  • ├─ Series: FX1S – ultra-compact PLC series
  • ├─ I/O Configuration
  • │ ├─ Input points: 12 (24V DC sink/source, integrated)
  • │ └─ Output points: 8 relay (2A max per point, 8A total common)
  • ├─ Electrical Ratings
  • │ ├─ Input voltage: 24V DC ±10%
  • │ ├─ Power consumption: ≤ 10W
  • │ └─ Isolation: Photocoupler (inputs) / relay isolation (outputs)
  • ├─ Performance & Speed
  • │ ├─ Basic instruction speed: 0.55–0.7 µs
  • │ ├─ High-speed counters: 2 channels (C235–C255)
  • │ └─ Pulse catch inputs: 6 points (10µs min. pulse width)
  • ├─ Environmental & Durability
  • │ ├─ Operating temperature: 0°C to +55°C
  • │ ├─ Storage temperature: -20°C to +70°C
  • │ ├─ Humidity: 10–90% RH non-condensing
  • │ ├─ Vibration resistance: 5–150 Hz, 0.5 mm amplitude
  • │ ├─ Noise immunity: IEC 61131-2 industrial grade
  • │ └─ Protection class: IP10 (open type, suitable for enclosure)
  • ├─ Resolution & Accuracy
  • │ ├─ Timer resolution: 1 ms / 10 ms / 100 ms selectable
  • │ └─ Counter resolution: up to 60 kHz (hardware counter)
  • ├─ Mounting & Dimensions
  • │ ├─ Mounting: DIN rail (35mm) or direct panel screws
  • │ └─ Dimensions: 75 × 90 × 75 mm (W×H×D)
  • └─ Certifications: CE, UL (E175732), cUL, RoHS

🔧 Installation & Wiring Guide

  • ├─ Mechanical mounting
  • │ ├─ DIN rail: Snap onto 35mm rail – no tools required
  • │ └─ Panel mount: Use M4 screws (2 mounting holes)
  • ├─ Power wiring
  • │ ├─ Connect 24V DC to [L] and [N] terminals (reverse polarity protected)
  • │ └─ Ground terminal to Class D grounding (≤100Ω)
  • ├─ Input wiring
  • │ ├─ Sink/source common selectable per COM terminal
  • │ └─ Input impedance: 4.3kΩ, ON voltage ≥15V DC
  • ├─ Output relay wiring
  • │ ├─ Max load: 2A resistive per point, 8A per common
  • │ └─ Use surge suppressor for inductive loads (diode or RC snubber)
  • └─ Clearance & ventilation: Keep 50mm above/below unit for cooling

🛠️ Commissioning & Maintenance

  • ├─ Programming setup
  • │ ├─ Software: GX Developer (V8.0+) or GX Works2
  • │ └─ Cable: SC-09 or USB-SC09-FX (RS422 connection)
  • ├─ No battery – maintenance free
  • │ ├─ EEPROM retains program without backup battery
  • │ └─ No periodic battery replacement costs
  • ├─ Diagnostic LEDs
  • │ ├─ POWER (green), RUN (green), ERROR (red)
  • │ └─ Input/Output status LEDs for each point
  • └─ Troubleshooting: Built-in watchdog timer and self-diagnostic error code

🔄 Compatibility & Communication

  • ├─ Programming compatibility
  • │ ├─ GX Developer / GX Works2 (full instruction set support)
  • │ └─ Ladder logic, SFC, and instruction list
  • ├─ Communication expansion boards (via BD slot)
  • │ ├─ FX1N-232-BD: RS232C communication
  • │ ├─ FX1N-485-BD: RS485 (Modbus RTU)
  • │ └─ FX1N-422-BD: RS422 for programming panel link
  • └─ I/O expansion: No main extension modules, but functional boards add limited I/O

📜 Certifications & Compliance

  • ├─ UL Listed (E175732) – USA & Canada safety standards
  • ├─ CE Marked – EMC and Low Voltage Directive (EU)
  • ├─ cUL Certified – Canadian electrical code compliance
  • ├─ RoHS – Hazardous substance restriction
  • └─ IEC 61131-2 – Industrial control equipment compliance

🎯 Expert Review & Manager Insight

  • ├─ Automation Engineer Review: “FX1S-20MR-001 packs reliable relay outputs, high-speed counters, and no-battery convenience into a tiny case. Perfect for small packaging lines and conveyor logic. The relay contacts handle moderate loads without extra interfacing.”
  • └─ Product Manager Insight: “For OEMs chasing cost efficiency without losing Mitsubishi robustness, this PLC wins. Simple DIN mount, 12-month warranty, and 24h dispatch ensure project continuity. Choose relay version for mixed voltage loads; MT version if servo pulses needed.”

🏭 Applications & Suitable Equipment

  • ├─ Packaging machinery – small baggers, carton sealers, label applicators
  • ├─ Textile equipment – winding units, knitting machines, tension control
  • ├─ HVAC & building automation – fan coil units, damper actuators
  • ├─ Conveyor systems – motor starters, accumulation logic, safety interlock
  • ├─ Special purpose OEM machines – printing, woodworking, food processing
  • └─ Small process skids – mixing, dosing, and batch control

❓ Frequently Asked Questions

  • ├─ Q1: What is the difference between FX1S-20MR and FX1S-20MT models?
  • │ └─ A: MR = relay outputs (2A, ideal for AC/DC mixed loads). MT = transistor sink output (0.5A, supports 2×100kHz pulses for servo/stepper positioning). Choose MR for general switching, MT for motion control.
  • ├─ Q2: Does this PLC support expansion I/O modules?
  • │ └─ A: No. FX1S series does not accept extension units. However, you can add function boards (RS232/485) via the BD slot. For expandable I/O, consider FX3G series.
  • ├─ Q3: Is program retention battery-free?
  • │ └─ A: Yes. Built-in EEPROM (2,000 steps) stores program permanently. No battery required – zero maintenance.
  • ├─ Q4: What voltage supply does this model use?
  • │ └─ A: 24V DC ±10% (nominal). Do not connect to 110V AC or 220V AC. For AC version, order FX1S-20MR-ES/UL.
  • ├─ Q5: Can I use high-speed counters for encoder feedback?
  • │ └─ A: Yes. Supports up to 2 high-speed counters (60kHz single-phase / 10kHz two-phase). Perfect for positioning or speed monitoring.
  • ├─ Q6: Experience-based – best practices for relay longevity?
  • │ └─ A: For inductive loads (motors, solenoids), always install surge suppression (diode for DC, RC snubber for AC). Reduces contact wear and extends relay life beyond 200k operations.
  • ├─ Q7: Which software is compatible?
  • │ └─ A: GX Developer (version 8.0 or later) and GX Works2. Both support full FX1S instruction set, online monitoring, and diagnostics.
  • └─ Q8: What is the maximum switching frequency for relay outputs?
  • └─ A: Mechanical life: 20 million cycles (no load). Electrical life: 200k cycles at rated load. Avoid PWM or frequent on/off >5Hz.

📌 Selection Guide – Choose the Right PLC

  • ├─ Select FX1S-20MR-001 when:
  • │ ├─ You need 12–20 I/O with relay outputs (2A per point).
  • │ ├─ Power supply is 24V DC available.
  • │ ├─ Compact size and no-battery operation is a priority.
  • │ └─ Application involves solenoids, contactors, lamps, small motors.
  • ├─ Choose FX1S-20MT (transistor) if:
  • │ ├─ You require high-speed pulse outputs (100kHz) for stepper/servo drives.
  • │ └─ Frequent switching (PWM) and longer electrical life.
  • ├─ Consider FX3G or FX3U series when:
  • │ ├─ You need more than 30 I/O points or analog expansion.
  • │ └─ Advanced networking (CC-Link, Ethernet) is required.
  • └─ Pro Tip: For mixed AC/DC load panels, relay version provides isolation and voltage flexibility without external relays.

📦 Package Contents & Shipping Details

  • ├─ In the box
  • │ ├─ 1 × FX1S-20MR-001 PLC unit (relay outputs, 24V DC)
  • │ ├─ 1 × Quick reference manual (English, Japanese, Chinese)
  • │ ├─ 1 × Terminal label sheet & DIN rail stoppers
  • │ └─ Warranty card – 12-month limited warranty
  • ├─ Shipping & dispatch
  • │ ├─ Processing time: 12–24 hours after order confirmation
  • │ └─ Express carriers: FedEx, UPS, DHL worldwide priority
  • └─ Tracking: Tracking number provided within 24h of dispatch

📞 Contact – Sales & Technical Support

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandMitsubishi
  • Part NumberFX1S-20MR-001
  • ConditionOriginal Brand New
  • Warranty12 Months

Additional information

Weight0.3 kg
Dimensions75 × 90 × 75 mm
Country Of Origin

United States

Customers Reviews

There are no reviews yet.

Be the first to review “FX1S-20MR-001 – Mitsubishi Electric FX1S Series Compact PLC, 20 I/O Relay Type”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart