Product details
FCST1030MF-HT Heated Metal-Seal MFC from Fujikin
FCST1030MF-HT is a heated mass flow controller in the FCST T1000 Series. It keeps the wetted path at 50-80°C. This stops condensable gases from forming liquid drops. The unit handles 6-30 SLM (N2 equivalent). It uses a metal Au gasket seal for tight leak control. A bellows-sealed metal diaphragm valve gives stable flow. The FCST1030MF-HT fits CVD, etch and other lines that use liquefied sources.
Technical Data
- Brand: Fujikin
- Model: FCST1030MF-HT
- Series: FCST T1000 Series (FCS-T1000MF-HT High Temperature)
- Full-scale flow range: 6-30 SLM (N2 equivalent)
- Accuracy: ±1% FS (2-100% FS)
- Repeatability: ±0.2% FS
- Response time: ≤1 sec
- Linearity: Covered by the ±1% FS accuracy spec
- Resolution and control range: 2-100% FS turndown
- Gas type: Customer-specified process gas; heated for condensable and high-vapor-pressure gases
- Operating temperature: 50-80°C heated; custom calibration temperature on request
- Operating pressure: 400 kPaG maximum
- Wetted materials: SUS316L stainless steel; PCTFE seats
- Seal: Metal Au gasket
- Leak integrity: ≤1×10⁻¹¹ Pa·m³/s He
- Valve type: Bellows-sealed metal diaphragm valve; N/O or N/C
- Electrical interface: Analog 0-5 VDC (±15 VDC supply); +24 VDC (0-5 VDC or 4-20 mA); RS-485, DeviceNet (T1000MF only)
- Power supply: ±15 VDC (0-5 VDC analog); +24 VDC option
- Dimensions: 125 (H) × 124 (W) × 70 (D) mm
- Surface finish: EP option
Best-Fit Equipment and Applications
- CVD tools that feed liquefied precursors such as TEOS or metal-organic sources.
- Etch chambers that use high-vapor-pressure gases.
- Gas cabinets and VMB lines where cold spots cause condensation.
- Diffusion and thin-film deposition systems with heated gas trains.
- R&D fabs that test low-volatility chemistries.
- Any line that needs 6-30 SLM flow with metal-seal purity.
Installation Guide
- Mount the unit with the flow arrow pointing downstream.
- Warm the unit to the set point before you open gas flow.
- Insulate the heated body to hold 50-80°C.
- Keep line pressure at or below 400 kPaG.
- Flush the line before you connect it.
- Check the Au gasket joints for leaks.
- Wire the supply per your interface choice.
Setup and Maintenance
- Set the heat point and wait for it to stabilize.
- Zero the unit at the working temperature.
- Use the remote control substrate to cut wiring runs.
- Read status over RS-485 or DeviceNet.
- No cold spots means less cleaning. This extends PM cycles.
- Replace the Au gasket only when leak checks fail.
Compatibility Notes
- Analog 0-5 VDC and 4-20 mA modes fit most tool controllers.
- RS-485 and DeviceNet links match common fab networks.
- The body size fits the T1000 family. Swaps need little new hardware.
- Heated flow path works with the same gases as the standard T1000MF.
Certifications
- CE
- RoHS compliant
- EP surface finish option
Packing List
- FCST1030MF-HT heated mass flow controller, one unit
- Calibration certificate
- Safety and compliance sheet
- Electrical connector kit, as ordered
- Au gasket fittings, as ordered
FAQ
Why does this unit run hot?
Heat keeps condensable gases in vapor form. Cold spots cause droplets, and droplets spoil flow control.
Which gases need heat most?
Liquefied sources such as TEOS and high-vapor-pressure dopants gain the most. Many other precursors also benefit.
What happens if the heat drops below range?
Gas may condense on the seat. Flow then drifts. Keep the body at 50-80°C at all times.
Can I order a custom calibration temperature?
Yes. Fujikin offers a customer-specified calibration point. In our field experience, matching calibration to the real line temperature cuts zero drift on startup.
How does the metal seal help?
The Au gasket holds ≤1×10⁻¹¹ Pa·m³/s He. This protects operators and keeps costly gas inside the line.