🔷 Flexem F5-MD1616R – High Density Digital I/O Module

  • F5-MD1616R – 32‑point digital combo module
    • Inputs: 16 bipolar (source/sink), 24 VDC, 7 mA
    • Outputs: 16 transistor (R type), 0.5 A per point
    • Protection: Short‑circuit with auto‑recovery every 10ms
    • Isolation: Optocoupler, 500 VAC between field and logic

📥 Input Side – 16 Points Bipolar

  • Electrical ratings
    • Rated voltage: 24 VDC (range 0…28.8 V)
    • Rated current: 7 mA at 24 V
    • Peak voltage: 30 V (max 1 hour/day)
    • Input impedance: 3.3 kΩ
  • Switching thresholds
    • State 1 (ON): >15 V (2.5…9 mA)
    • State 0 (OFF): <5 V (0…1.0 mA)
  • Signal processing
    • Filter time: Default 1ms (16 steps up to 100ms, incl. unfiltered)
    • Sensor compatibility: 2‑wire or 3‑wire, sink/source type
  • Cable guidelines
    • Shielded cable: Max 100 m
    • Unshielded cable: Max 50 m

📤 Output Side – 16 Transistor (R Type)

  • Power specs
    • Rated voltage: 24 VDC (range 19.2…28.8 V)
    • Rated current: 0.5 A per point, 0.5 A per group
    • Voltage drop: ≤1 V at full load
    • Leakage current (off): <5 μA
  • Load handling
    • Lamp load: Max 2.4 W
    • Derating: None (full current over temperature range)
  • Switching performance
    • Turn‑on time: <34 μs
    • Turn‑off time: <250 μs
    • Max output frequency: 1 kHz (resistive load)
  • Protection features
    • Short‑circuit: Yes (peak 1.3 A, self‑recovery every 10ms)
    • Clamping voltage: 39 VDC ±1 V
  • Wiring
    • Unshielded cable: Max 50 m
    • Isolation: 500 VAC between output and internal logic

🌡️ Environmental & General Data

  • Temperature ranges
    • Operating: -20…+60 °C
    • Storage: -40…+85 °C
  • Protection & immunity
    • Degree: IP20
    • EMC: According to IEC 61000-6-2

🔧 Installation & Setup

  • Mounting
    • DIN rail: TS35, width compatible with Flexem system
    • Terminals: Spring‑cage, 0.2…1.5 mm² (removable)
  • Wiring notes
    • Power supply: 24 VDC to upper terminals
    • Inputs: Bipolar – common to GND or +24 V
    • Outputs: Transistor – load between +24 V and output

⚙️ Diagnostics & User Tips

  • LED indicators
    • Input LEDs: ON when signal >15 V
    • Output LEDs: ON when transistor conducts
    • Error LED: Flashes on short‑circuit/overload
  • Filter adjustment
    • 16 levels: From unfiltered to 100 ms (default 1 ms)
    • Use: Longer filter for noisy environments

📦 Package, Warranty & Shipping

  • In the box
    • 1x Flexem F5-MD1616R module
    • Quick start guide
    • Removable terminal blocks (pre‑fitted)
  • Warranty
    • 12 months from shipment date
    • Covers manufacturing defects
  • Shipping carriers
    • FedEx / UPS / DHL Express
    • Tracking provided within 24 hours

🏭 Where to Use F5-MD1616R

  • Large conveyor systems: Monitor many sensors, control many actuators
  • Packaging lines: High density I/O for complex machines
  • Material handling: Remote I/O racks with many signals
  • Factory automation: Central control panels with high I/O count
  • Assembly machines: Combine sensor feedback and output control

❓ Expert FAQ – Selection & Experience

  • Why choose F5-MD1616R over multiple smaller modules?
    • Answer: The F5-MD1616R saves DIN rail space and wiring time. One module gives 32 I/O points instead of using four 8‑point modules. Very cost‑effective.
  • Can inputs and outputs use different voltage supplies?
    • Answer: Yes, inputs use 24V from field devices. Outputs use separate 24V supply (19.2‑28.8V). They are isolated from each other.
  • What is the group current limit for outputs?
    • Answer: Each group of outputs shares 0.5A total. If you use multiple outputs in one group, their combined current must stay under 0.5A.
  • How does self‑recovery after short circuit work?
    • Answer: Every 10ms the module checks if the short is gone. If yes, output turns back on automatically. No manual reset needed.
  • Can I mix NPN and PNP sensors on inputs?
    • Answer: Yes, inputs are bipolar. They work with both NPN (sinking) and PNP (sourcing) sensors. Very flexible for different field devices.
  • What is delivery time for F5-MD1616R?
    • Answer: We ship within 24 hours via FedEx, UPS, or DHL. Express delivery takes 3‑5 business days worldwide.
  • Is the 12‑month warranty extendable?
    • Answer: Yes, contact sales@powergearx.com for extended warranty options beyond the standard 12 months.

📬 Contact & Support

 

Specifications

  • Part NumberF5-MD1616R
  • ConditionBrand New
  • Warranty.12 Months

Additional information

Weight0.065 kg
Dimensions111 × 76 × 18 mm
Country Of Origin

United States

Customers Reviews

There are no reviews yet.

Be the first to review “F5-MD1616R Flexem 16 Input 16 Output Digital Module | 24VDC Bipolar I/O”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart