Product details

E94AMHE0044 Lenze 9400 HighLine Multi Drive Axis Module

The E94AMHE0044 is a Lenze axis module in the Servo Drives 9400 HighLine Multi Drive series. It mounts in a DC-bus cabinet. It drives a 1.5 kW 4-pole asynchronous motor in the 400 V class. Rated output current is 5 A at 4 kHz. Peak current is 7.5 A. Short-term current reaches 16 A. The overload factor is 4. CANopen is built in. Two slots add function modules. This module suits compact multi-axis machines that need more power than the 0.75 kW class.

Product Structure at a Glance

  • E94AMHE0044
    • Hardware
      • 1.5 kW nominal, ASM 4-pole, 400 V class
      • 5 A rated output current at 4 kHz
      • 7.5 A max output current
      • 16 A max short-term current
      • Overload factor 4
      • 6.7 A rated DC-bus current
      • 150 W power loss
    • Communication
      • CANopen on board
      • USB diagnostics via E94AZCUS adapter
      • Two E94AYC extension slots
      • One memory slot, one safety slot
    • Electrical
      • DC-bus input 260 V to 775 V
    • Environment
      • Operating -10 °C to +55 °C
      • Derate 2.5 %/°C above +45 °C
      • Storage -25 °C to +60 °C
      • Transport -25 °C to +70 °C
      • Altitude up to 4000 m, derate 5 % per 1000 m above 1000 m
      • Vibration class 2M2, EN 60068-2-6
      • Humidity class 3K3, no %RH published
      • IP20, NEMA 250 type 1
    • Physical
      • 350 mm x 60 mm x 288 mm with 507 backplane
      • 4 kg
    • Lifecycle
      • Active L-force range, verified 2026-10

Key Technical Specifications

  • Brand: Lenze
  • Model: E94AMHE0044
  • Series: Servo Drives 9400 HighLine Multi Drive
  • Module type: Axis module for DC-bus cabinet mounting
  • Rated motor power: 1.5 kW nominal (ASM 4-pole, 400 V class)
  • Rated output current: 5 A at 4 kHz switching frequency
  • Max output current: 7.5 A
  • Max short-term output current: 16 A
  • Overload factor: 4
  • Rated DC-bus current: 6.7 A nominal
  • Power loss: 150 W
  • Supply voltage: DC 260 V to 775 V
  • Built-in ports: CANopen; USB diagnostics via E94AZCUS
  • Expansion: Two E94AYC slots, one memory slot, one safety slot
  • Operating temperature: -10 °C to +55 °C, EN 60721-3-3 class 3K3
  • Temperature derating: 2.5 % per °C above +45 °C
  • Storage temperature: -25 °C to +60 °C, EN 60721-3-1 class 1K3
  • Transport temperature: -25 °C to +70 °C, EN 60721-3-2 class 2K3
  • Site altitude: Up to 4000 m AMSL; derate 5 % per 1000 m above 1000 m
  • Vibration resistance: Class 2M2; 10 to 57 Hz at ±0.075 mm; 57 to 150 Hz at 1.0 g
  • Marine vibration: Germanischer Lloyd; 5 to 13.2 Hz at ±1 mm; 13.2 to 100 Hz at 0.7 g
  • Relative humidity: Climatic class 3K3; no specific %RH published
  • Protection rating: IP20 (EN 60529); NEMA 250 type 1
  • Dimensions (H x W x D): 350 mm with 507 backplane x 60 mm x 288 mm
  • Weight: 4 kg

Installation Guide

  • Fix the module on the 507 installation backplane.
  • Keep the 60 mm width clear for airflow.
  • Connect the DC-bus within 260 V to 775 V.
  • Wire a 1.5 kW 4-pole ASM motor.
  • Link the CANopen port to the network.
  • Add E94AYC modules in the free slots.
  • Respect IP20 and use a closed cabinet.
  • Derate above +45 °C or 1000 m.

Commissioning and Maintenance

  • Enter motor data in the Lenze tool.
  • Confirm the 4 kHz switching setting.
  • Set the CANopen node and baud rate.
  • Use the E94AZCUS adapter for diagnostics.
  • Check DC-bus voltage before power-up.
  • Clean the heat sink on schedule.
  • Inspect terminals at each service.
  • Record overload trips for trend checks.

Compatibility Notes

  • Fits Lenze 9400 HighLine Multi Drive systems.
  • Drives 1.5 kW 4-pole ASM motors in the 400 V class.
  • Takes E94AYC communication and extension modules.
  • Supports one memory module and one safety module.
  • Shares a DC-bus with other axis modules.
  • Uses CANopen for field integration.

Approvals and Standards

  • EN 60721-3-3 class 3K3, operation.
  • EN 60721-3-1 class 1K3, storage.
  • EN 60721-3-2 class 2K3, transport.
  • EN 60068-2-6 vibration.
  • EN 60529 IP20.
  • NEMA 250 type 1.
  • Germanischer Lloyd marine vibration.

Packing List and Warranty

  • One E94AMHE0044 axis module.
  • One backplane reference sheet.
  • One safety and compliance note.
  • 12-month warranty from delivery.
  • Ships in 12 to 24 hours after order confirmation.
  • Delivery by FedEx, UPS, or DHL.

Expert Review

The E94AMHE0044 adds real power in the same slim body. It doubles the motor rating of the 0.75 kW class. The 16 A short-term current covers tough starts. The 4x overload factor keeps peaks safe. Built-in CANopen saves wiring time. Two slots keep room for growth. Plan for derating above +45 °C. Cabinet airflow is the main design point. This is a strong choice for mid-size asynchronous motor control.

Manager’s Insight

This unit moves fast in multi-axis retrofit work. Buyers like the Lenze build and the active 9400 lifecycle. Keep spare E94AYC modules in stock. Offer the E94AZCUS adapter as an add-on. Most orders cover two or more axes per cabinet. Fast dispatch in 12 to 24 hours wins urgent jobs. Ask for a quote at sales@powergearx.com.

Best Fit Devices and Applications

  • Multi-axis cabinets with shared DC-bus.
  • Packaging lines with tight spacing.
  • Conveyor and material handling systems.
  • Printing and textile machines.
  • Retrofit projects that keep 400 V motors.
  • Cells that run on CANopen.

FAQ

  • Q: What sets this module apart from the 0.75 kW class?
    A: It drives a 1.5 kW motor and delivers 16 A short-term current.
  • Q: How much power loss should I plan for?
    A: About 150 W per module at rated load.
  • Q: Can I run it on a shared DC-bus?
    A: Yes. It is made for DC-bus cabinet mounting.
  • Q: What is the rated DC-bus current?
    A: 6.7 A nominal.
  • Q: How do I get help with a quote?
    A: Email sales@powergearx.com or message +86 18030005825 on WhatsApp.
  • Q: From experience, what do buyers forget?
    A: They forget the 2.5 %/°C derating above +45 °C.
  • Q: Any tip on cabinet layout?
    A: Leave clear space above and below the 60 mm body.
  • Q: How should I choose the right variant?
    A: Match motor power, current, and bus voltage first. Then pick E94AYC modules for your network.
  • Q: Should I keep spares?
    A: Yes. Hold one spare axis module and one E94AYC module per cabinet.
  • Q: What warranty applies?
    A: 12 months from the delivery date.
  • Q: How fast do you ship?
    A: Within 12 to 24 hours by FedEx, UPS, or DHL.

Buying Guide

  • Check that your motor is a 1.5 kW 4-pole ASM.
  • Confirm the cabinet uses a DC-bus in the 260 V to 775 V range.
  • List the E94AYC modules your network needs.
  • Plan for derating above +45 °C and 1000 m.
  • Order spares for critical lines.
  • Ask for a quote at sales@powergearx.com.

Questions? Reach our team at sales@powergearx.com or +86 18030005825 on WhatsApp. We reply fast and ship in 12 to 24 hours.

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE94AMHE0044
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E94AMHE0044 Lenze Servo Axis Module CANopen DC-Bus Cabinet Drive”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart