Product details
E94AMHE0044 Lenze 9400 HighLine Multi Drive Axis Module
The E94AMHE0044 is a Lenze axis module in the Servo Drives 9400 HighLine Multi Drive series. It mounts in a DC-bus cabinet. It drives a 1.5 kW 4-pole asynchronous motor in the 400 V class. Rated output current is 5 A at 4 kHz. Peak current is 7.5 A. Short-term current reaches 16 A. The overload factor is 4. CANopen is built in. Two slots add function modules. This module suits compact multi-axis machines that need more power than the 0.75 kW class.
Product Structure at a Glance
- E94AMHE0044
- Hardware
- 1.5 kW nominal, ASM 4-pole, 400 V class
- 5 A rated output current at 4 kHz
- 7.5 A max output current
- 16 A max short-term current
- Overload factor 4
- 6.7 A rated DC-bus current
- 150 W power loss
- Communication
- CANopen on board
- USB diagnostics via E94AZCUS adapter
- Two E94AYC extension slots
- One memory slot, one safety slot
- Electrical
- DC-bus input 260 V to 775 V
- Environment
- Operating -10 °C to +55 °C
- Derate 2.5 %/°C above +45 °C
- Storage -25 °C to +60 °C
- Transport -25 °C to +70 °C
- Altitude up to 4000 m, derate 5 % per 1000 m above 1000 m
- Vibration class 2M2, EN 60068-2-6
- Humidity class 3K3, no %RH published
- IP20, NEMA 250 type 1
- Physical
- 350 mm x 60 mm x 288 mm with 507 backplane
- 4 kg
- Lifecycle
- Active L-force range, verified 2026-10
- Hardware
Key Technical Specifications
- Brand: Lenze
- Model: E94AMHE0044
- Series: Servo Drives 9400 HighLine Multi Drive
- Module type: Axis module for DC-bus cabinet mounting
- Rated motor power: 1.5 kW nominal (ASM 4-pole, 400 V class)
- Rated output current: 5 A at 4 kHz switching frequency
- Max output current: 7.5 A
- Max short-term output current: 16 A
- Overload factor: 4
- Rated DC-bus current: 6.7 A nominal
- Power loss: 150 W
- Supply voltage: DC 260 V to 775 V
- Built-in ports: CANopen; USB diagnostics via E94AZCUS
- Expansion: Two E94AYC slots, one memory slot, one safety slot
- Operating temperature: -10 °C to +55 °C, EN 60721-3-3 class 3K3
- Temperature derating: 2.5 % per °C above +45 °C
- Storage temperature: -25 °C to +60 °C, EN 60721-3-1 class 1K3
- Transport temperature: -25 °C to +70 °C, EN 60721-3-2 class 2K3
- Site altitude: Up to 4000 m AMSL; derate 5 % per 1000 m above 1000 m
- Vibration resistance: Class 2M2; 10 to 57 Hz at ±0.075 mm; 57 to 150 Hz at 1.0 g
- Marine vibration: Germanischer Lloyd; 5 to 13.2 Hz at ±1 mm; 13.2 to 100 Hz at 0.7 g
- Relative humidity: Climatic class 3K3; no specific %RH published
- Protection rating: IP20 (EN 60529); NEMA 250 type 1
- Dimensions (H x W x D): 350 mm with 507 backplane x 60 mm x 288 mm
- Weight: 4 kg
Installation Guide
- Fix the module on the 507 installation backplane.
- Keep the 60 mm width clear for airflow.
- Connect the DC-bus within 260 V to 775 V.
- Wire a 1.5 kW 4-pole ASM motor.
- Link the CANopen port to the network.
- Add E94AYC modules in the free slots.
- Respect IP20 and use a closed cabinet.
- Derate above +45 °C or 1000 m.
Commissioning and Maintenance
- Enter motor data in the Lenze tool.
- Confirm the 4 kHz switching setting.
- Set the CANopen node and baud rate.
- Use the E94AZCUS adapter for diagnostics.
- Check DC-bus voltage before power-up.
- Clean the heat sink on schedule.
- Inspect terminals at each service.
- Record overload trips for trend checks.
Compatibility Notes
- Fits Lenze 9400 HighLine Multi Drive systems.
- Drives 1.5 kW 4-pole ASM motors in the 400 V class.
- Takes E94AYC communication and extension modules.
- Supports one memory module and one safety module.
- Shares a DC-bus with other axis modules.
- Uses CANopen for field integration.
Approvals and Standards
- EN 60721-3-3 class 3K3, operation.
- EN 60721-3-1 class 1K3, storage.
- EN 60721-3-2 class 2K3, transport.
- EN 60068-2-6 vibration.
- EN 60529 IP20.
- NEMA 250 type 1.
- Germanischer Lloyd marine vibration.
Packing List and Warranty
- One E94AMHE0044 axis module.
- One backplane reference sheet.
- One safety and compliance note.
- 12-month warranty from delivery.
- Ships in 12 to 24 hours after order confirmation.
- Delivery by FedEx, UPS, or DHL.
Expert Review
The E94AMHE0044 adds real power in the same slim body. It doubles the motor rating of the 0.75 kW class. The 16 A short-term current covers tough starts. The 4x overload factor keeps peaks safe. Built-in CANopen saves wiring time. Two slots keep room for growth. Plan for derating above +45 °C. Cabinet airflow is the main design point. This is a strong choice for mid-size asynchronous motor control.
Manager’s Insight
This unit moves fast in multi-axis retrofit work. Buyers like the Lenze build and the active 9400 lifecycle. Keep spare E94AYC modules in stock. Offer the E94AZCUS adapter as an add-on. Most orders cover two or more axes per cabinet. Fast dispatch in 12 to 24 hours wins urgent jobs. Ask for a quote at sales@powergearx.com.
Best Fit Devices and Applications
- Multi-axis cabinets with shared DC-bus.
- Packaging lines with tight spacing.
- Conveyor and material handling systems.
- Printing and textile machines.
- Retrofit projects that keep 400 V motors.
- Cells that run on CANopen.
FAQ
- Q: What sets this module apart from the 0.75 kW class?
A: It drives a 1.5 kW motor and delivers 16 A short-term current. - Q: How much power loss should I plan for?
A: About 150 W per module at rated load. - Q: Can I run it on a shared DC-bus?
A: Yes. It is made for DC-bus cabinet mounting. - Q: What is the rated DC-bus current?
A: 6.7 A nominal. - Q: How do I get help with a quote?
A: Email sales@powergearx.com or message +86 18030005825 on WhatsApp. - Q: From experience, what do buyers forget?
A: They forget the 2.5 %/°C derating above +45 °C. - Q: Any tip on cabinet layout?
A: Leave clear space above and below the 60 mm body. - Q: How should I choose the right variant?
A: Match motor power, current, and bus voltage first. Then pick E94AYC modules for your network. - Q: Should I keep spares?
A: Yes. Hold one spare axis module and one E94AYC module per cabinet. - Q: What warranty applies?
A: 12 months from the delivery date. - Q: How fast do you ship?
A: Within 12 to 24 hours by FedEx, UPS, or DHL.
Buying Guide
- Check that your motor is a 1.5 kW 4-pole ASM.
- Confirm the cabinet uses a DC-bus in the 260 V to 775 V range.
- List the E94AYC modules your network needs.
- Plan for derating above +45 °C and 1000 m.
- Order spares for critical lines.
- Ask for a quote at sales@powergearx.com.
Questions? Reach our team at sales@powergearx.com or +86 18030005825 on WhatsApp. We reply fast and ship in 12 to 24 hours.
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/