Over 50,000 hot-selling automation module components.

DL35-B15852 Time-of-Flight Sensor 35m | SICK Dx35 100µm Resolution

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: DL35-B15852
Brands:

Product details

DL35-B15852 – SICK Dx35 Time-of-Flight Distance Sensor

Brand: SICK | Model: DL35-B15852 | Series: Dx35 | Type: Time-of-Flight Distance Sensor

200mm to 35,000mm measuring range. 100µm resolution. ±15mm accuracy. Infrared laser (Class 1). IO-Link ready. Analog and digital outputs. Compact and rugged.

  • Range: 0.2 to 35 meters (on reflective tape)
  • Resolution: 100 µm (0.1 mm)
  • Accuracy: ±15 mm typical
  • Response time: 2.5 to 96.5 ms (selectable)
  • Outputs: 1-2 digital (PNP/NPN) + analog (0-10V / 4-20mA)

Technical Specifications

  • General
    • Product ID: DL35-B15852
    • Alternate P/N: 1057658
    • Brand: SICK
    • Series: Dx35
    • Weight: 65 g
  • Measurement
    • Range: 200 mm to 35 m (on diamond-grade reflective tape)
    • Resolution: 100 µm
    • Repeatability: ≥0.5 mm
    • Accuracy: Typ. ±15 mm
  • Laser & Light
    • Light source: Infrared laser, Class 1 (IEC 60825-1)
    • Service life: 100,000 hours (at 25°C)
    • Spot size: 15mm x 15mm (at 2m)
  • Outputs
    • Digital: 1-2 push-pull (PNP/NPN), ≤100 mA
    • Analog: 0-10V (≥50kΩ) or 4-20mA (≤450Ω)
    • Analog resolution: 12-bit
    • IO-Link: V1.1 (process data, parameterization, diagnostics)
  • Timing
    • Response time: Selectable 2.5 / 6.5 / 12.5 / 24.5 / 96.5 ms
    • Switching frequency: 333 / 100 / 50 / 25 / 6 Hz
    • Output time: 1 / 2 / 4 / 8 / 32 ms
    • Init time: ≤500 ms, Warm-up ≤20 min
  • Electrical
    • Supply voltage: 12 to 30V DC
    • Power consumption: ≤1.7W
    • Ripple: ≤5 Vpp
    • Connection: M12 5-pin male connector
  • Mechanical & Environment
    • Dimensions: 32 x 58.67 x 42.7 mm (W x H x D)
    • Housing: ABS/PC plastic, PMMA window
    • IP rating: IP65 / IP67
    • Operating temp: -30 to +55°C (Uv ≤24V)
    • Storage temp: -40 to +75°C
    • Humidity: ≤95% non-condensing
    • Shock & vibration: EN 60068-2-27 / -6 / -64
    • EMC: EN 61000-6-2, -6-3, -6-4

Expert Review

“Precise long-range sensing.” 35m range with 100µm resolution. ±15mm accuracy. Selectable response time from 2.5ms to 96.5ms – adapt to your application. IO-Link enables easy diagnostics and parameterization.

Manager’s Insight

“Versatile and robust.” One sensor covers many tasks – distance, position, fill level. Analog and digital outputs in one device. IP67 rating withstands harsh environments. Compact size saves space. 12-month warranty included.

Typical Applications

  • Distance and position measurement
  • Fill level monitoring (tanks, silos)
  • Crane and hoist positioning
  • Automated guided vehicle (AGV) navigation
  • Stacker crane positioning

Compatibility & Integration

  • IO-Link V1.1 for easy integration with PLCs
  • Analog output: 0-10V or 4-20mA (selectable)
  • Digital output: Push-pull (PNP/NPN) – flexible wiring
  • SOPAS or IO-Link tools for configuration
  • Teach-in function for quick setup

Compare with Other Models

  • DL35-B15852 – 35m, 100µm, IO-Link, analog+digital
  • DL35-B15853 – same but with different output config
  • DL35-B156 – 15m range, lower cost
  • DT35 – standard distance sensor, no IO-Link

Certifications

  • CE, UL, TÜV, EAC
  • Laser Class 1 (IEC 60825-1:2014)
  • EMC compliant with EN 61000-6-2, -6-3, -6-4
  • RoHS compliant

Package & Warranty

  • In box: DL35-B15852 sensor, M12 connector, quick start guide.
  • Warranty: 12 months.
  • Shipping: 12-24h dispatch via FedEx, UPS, DHL (tracking provided).

Frequently Asked Questions

    • What is the maximum range without reflective tape?
    • Range depends on target reflectivity. Max 35m only with “diamond grade” reflective tape. For dark objects, range is shorter.

 

    • Can I use this sensor outdoors in sunlight?
    • Yes. Infrared light and class 1 laser work in sunlight. Avoid direct sunlight on the receiver lens.

 

    • What is the difference between response time and output time?
    • Response time is the measurement cycle. Output time is the update rate of analog/digital signals. Both are configurable.

 

    • Does the sensor have IO-Link?
    • Yes. IO-Link V1.1 is built-in. Use it for parameterization, diagnostics, and process data transfer.

 

    • Can I change the analog output from current to voltage?
    • Yes. Configure output Q2 as 4-20mA or 0-10V via software or teach-in.

 

  • What is the warm-up time?
  • Up to 20 minutes for full accuracy. During warm-up, accuracy may be slightly reduced.

Selection Guide

  • Choose DL35-B15852 if: you need 35m range with 100µm resolution and IO-Link.
  • For shorter range (15m): consider DL35-B156 (lower cost).
  • If you don’t need IO-Link: DT35 series offers basic analog/digital outputs.
  • Check your supply voltage: 12-30V DC – ensure clean power.
  • Mounting: Compact size fits tight spaces. Use M12 connector for quick wiring.

For inquiries: sales@powergearx.com |
+86 18030005825 (WhatsApp)

Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/

Specifications

  • BrandSICK
  • Part NumberDL35-B15852
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “DL35-B15852 Time-of-Flight Sensor 35m | SICK Dx35 100µm Resolution”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart