DECS-100-B15 Basler Electric AVR Digital Voltage Regulator DECS-100

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: DECS-100-B15
Brands:

Product details

Product Overview

  • DECS-100-B15 is a digital automatic voltage regulator from Basler Electric.
  • It controls the exciter field current on brushless AC generators.
  • A microprocessor runs the control loop for steady, repeatable output.
  • The PWM power stage delivers 63 Vdc at 7 Adc.
  • Users can order 10 Adc models for larger fields.
  • It holds voltage tight even with high harmonics.
  • The potted body takes heat, shock and vibration.
  • Setup runs on a PC with the included BESTCOMS software.

Technical Data

  • Brand: Basler Electric
  • Model: DECS-100-B15
  • Type: Digital automatic voltage regulator (AVR)
  • Field output: 63 Vdc at 7 Adc, PWM stage
  • Forcing output, 10 s: Up to 135 Vdc at 15 Adc
  • Minimum field resistance: 9 ohm
  • Input power: 88 to 250 Vac, 1 or 3 phase, 50 to 400 Hz
  • Input burden: 650 VA
  • Minimum build-up voltage: 6.0 Vac
  • Sensing input: 100/120, 200/240, 400/480 and 600 Vac
  • Sensing burden: Under 1 VA per phase, 50/60 Hz
  • Current sensing: 1 A or 5 A CT models, under 1 VA
  • Accessory input: -3 to +3 Vdc, setpoint shift -30 to +30 percent
  • Control modes: AVR, manual FCR 0 to 7 Adc, optional Var, optional PF
  • Stability: 20 standard settings plus 1 custom setting
  • Accuracy: ±0.25 percent from no load to full load
  • THD accuracy: ±0.25 percent at 20 percent THD, ±0.5 percent at 40 percent THD
  • Temperature drift: ±0.5 percent over a 40 C change
  • Response time: Within 1 cycle
  • Limits and protection: Field overvoltage, generator overvoltage, loss of sensing, OEL, UEL, soft start, V/Hz limit to 3X
  • Alarm relay: Form A, 7 A continuous, 240 Vac or 250 Vdc max
  • Port: RS-232 DB-9 on the rear, BESTCOMS on Windows
  • Operating temperature: -40 to +70 C
  • Storage temperature: -40 to +85 C
  • Shock: 20 G on three axes
  • Vibration: 1.2 G at 5 to 26 Hz, 0.036 in at 27 to 52 Hz, 5.0 G at 53 to 500 Hz
  • Salt fog: Per MIL-STD-810E
  • Weight: 2.42 lb (1.10 kg)
  • Size: 5.34 x 10.82 x 2.84 in (135.6 x 274.8 x 72.1 mm)

Certifications

  • UL recognized to UL6200
  • CSA certified
  • CE for EMC and LVD
  • EAC certified
  • Type approved by Bureau Veritas, DNV-GL and RMRS. The 10 Adc models skip these marine approvals.

Installation Guide

  • Mount the unit on a flat panel inside the generator cabinet.
  • Wire power input to a 88 to 250 Vac source.
  • Feed sensing from the generator terminals.
  • Fit a 1 A or 5 A CT for current sensing.
  • Connect the field leads to the output terminals.
  • Keep the field resistance at 9 ohm or more.
  • Hook the RS-232 port to a PC for setup.
  • Check all wires before the first start.

Setup and Maintenance

  • Load BESTCOMS on a Windows PC.
  • Set the sensing voltage to match the site.
  • Pick a stability setting, then fine tune.
  • Set the soft start ramp to protect the set.
  • Turn on OEL and UEL for safe limits.
  • Use the LEDs to read running states.
  • Check terminal torque at each service visit.
  • Back up settings after each change.

Best Fit Devices and Applications

  • Brushless AC generators in standby power.
  • Prime power gensets on ships and rigs.
  • Diesel and gas generator sets.
  • Hydro and steam turbine exciters.
  • Paralleled generator banks that need Var or PF control.
  • Remote sites that see heat, cold and vibration.

Compatibility

  • Works with shunt-fed and PMG-fed exciters.
  • Takes CT secondaries rated 1 A or 5 A.
  • Fits systems with 50/60 Hz sensing.
  • Pairs with Basler BESTCOMS software for setup.

Packing List

  • 1 x Basler DECS-100-B15 voltage regulator
  • 1 x BESTCOMS software
  • 1 x document pack

FAQ

  • Will this unit work on a 50 Hz set?
  • Yes. Sensing runs at 50/60 Hz and the power input spans 50 to 400 Hz.
  • What field resistance is too low?
  • Stay at 9 ohm or above. A lower value can overload the output stage.
  • Can I use it without a PMG?
  • Yes. Shunt feed works as long as build-up voltage reaches 6 Vac.
  • How do I stop voltage hunting?
  • Pick a slower stability setting, then raise it one step at a time.
  • What happens if a sensing wire opens?
  • The unit trips to manual mode and keeps the field current steady.
  • Do I need a laptop at every site?
  • No. The unit keeps its saved settings after power off.
  • Can I run two sets in parallel?
  • Yes. Add the CT input and set Var or PF control for load sharing.
  • Why does the alarm relay chatter?
  • Check for loose sensing wires or unstable input power first.

Specifications

  • BrandBasler Electric
  • Part NumberDECS-100-B15