Product details
Product Overview
The CTO163 is a digital output module from the SIGMATEK C-DIAS series. It gives you 16 outputs with 2A per channel. Each output switches +24V DC in positive (PNP) mode. Short-circuit protection is built in. The module fits the C-DIAS modular bus system. It suits machine builders who need dense, reliable output control.
Why Choose This Module
- 16 outputs in one compact module.
- 2A per channel drives valves, relays, and small loads directly.
- Short-circuit protection guards each output.
- Fast switching under 200µs on and off.
- UL listed for North American projects.
Technical Data
- Brand: SIGMATEK
- Model: CTO163 (also written CTO 163)
- Series: C-DIAS
- Type: Digital output module
- Outputs: 16 channels
- Switching: +24V DC, positive (PNP)
- Current per channel: 2A continuous
- Current per 4 channels: 6A at 100% duty
- Current per module: 24A at 100% duty
- Supply voltage: 18–30V DC, nominal +24V
- Voltage drop when on: ≤1V
- Residual current when off: ≤12µA
- Switch-on delay: under 200µs
- Switch-off delay: under 200µs
- Breaking energy: 0.65 J per channel, 1.95 J per 4 channels (HW V2.0+)
- Short-circuit protection: yes
- Status display: optional LEDs (yellow outputs, red voltage)
- Article numbers: 12-007-163 with LEDs, 12-007-163-O without LEDs
- Hardware version: 1.x to 2.x
- Standard: UL (E247993)
- Storage temperature: -20 to +85°C
- Operating temperature: 0 to +60°C
- Humidity: 0–95%, no condensation
- EMC immunity: EN 61000-6-2 (industrial)
Model Suffix Guide
- 12-007-163
- Standard unit with status LEDs.
- Yellow LEDs show output state.
- Red LED shows low supply voltage.
- 12-007-163-O
- Same module without LEDs.
- Lower cost for hidden installs.
- HW V2.0 or higher
- Adds internal protection for inductive loads.
- Raises breaking energy rating.
Installation Guide
- Snap the module onto the C-DIAS bus rail.
- Wire +24V supply to the 1–4 input terminals.
- Keep load current within 6A per 4-channel group.
- Use flyback diodes on inductive loads in older HW versions.
- Ground the panel before power-up.
- Check the red LED after power-on.
Setup and Maintenance
- Label each channel in your project file.
- Test outputs one by one at first start.
- Check terminal torque every six months.
- Clean dust from the module during shutdowns.
- Log fault events from the bus master.
- Replace modules only with power off.
Best Fit Applications
- Valve and relay banks in machine cells.
- Packaging lines with many actuators.
- Conveyor control panels.
- Test benches with dense I/O needs.
- Small pump and fan control cabinets.
Certification
- UL file E247993.
- EMC immunity per EN 61000-6-2.
Packing List
- 1 x CTO163 digital output module
- 1 x quick start sheet
- Protective packaging
FAQ
Q: Can one channel drive a solenoid valve?
A: Yes. Most 24V valves draw well under 2A. Add a flyback diode on older hardware.
Q: What happens if a load shorts?
A: The output shuts off. It recovers after the fault clears.
Q: Should I pick the LED or non-LED version?
A: Pick LEDs for fast field checks. Pick the -O version for closed panels.
Q: How much current can one 4-channel group take?
A: 6A at full duty. Spread heavy loads across groups.
Q: Does the module need a separate bus supply?
A: The C-DIAS bus uses +5V. The card draws it from the bus backplane.
Q: What is a common install mistake?
A: Overloading one group. Plan loads before wiring.

















There are no reviews yet.