Over 50,000 hot-selling automation module components.

ATV930C13N4 Schneider Altivar Process Drive 132 kW ND/HD VSD

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: ATV930C13N4
Brands:

Product details

Product Overview

  • Model ATV930C13N4 is a high-performance variable speed drive from Schneider Electric.
  • It belongs to the Altivar Process ATV930 series, built for heavy industrial use.
  • Moreover, this three-phase drive supports 380 to 480 V supplies with dual ND/HD ratings.
  • In addition, a built-in dynamic brake transistor saves space and wiring time.
  • For example, you can choose 132 kW (200 HP) in Normal Duty with 120% overload for 60 s.
  • Alternatively, pick 110 kW (150 HP) in Heavy Duty with 150% overload for 60 s.
  • It controls asynchronous motors in open or closed loop vector mode.
  • In addition, it drives synchronous PM and reluctance motors with encoder feedback.
  • Furthermore, an integrated STO safety function reaches SIL3 and Cat. PL e.
  • Also, a built-in Ethernet dual-port switch and Modbus serial port cut extra hardware.
  • Meanwhile, one option slot accepts PROFINET, EtherCAT, CANopen and more.
  • As a result, this drive suits pumps, fans, conveyors and process lines in demanding plants.

Technical Specifications

  • Brand: Schneider Electric
  • Model: ATV930C13N4
  • Series: Altivar Process ATV930
  • Module type: Three-phase variable speed drive
  • Supply voltage: 380 to 480 V three-phase, -15% to +10%, 50/60 Hz
  • Motor power ND: 132 kW (200 HP)
  • Motor power HD: 110 kW (150 HP)
  • Output frequency: 0.1 to 599 Hz
  • Switching frequency: 4 kHz nominal for U07N4 to D45N4; 2.5 kHz for D55N4 to C22N4
  • ND input current: 237 A at 380 V; 213 A at 480 V
  • ND continuous output: 250 A at nominal switching frequency
  • ND transient output: 300 A for 60 s (120% of In)
  • HD input current: 201 A at 380 V; 165 A at 480 V
  • HD continuous output: 211 A at nominal switching frequency
  • HD transient output: 317 A for 60 s (150% of In)
  • Analog inputs: 3 total; 2 configurable 0–10 V or 0/4–20 mA with PTC/PT100/PT1000/KTY84 probe input; 1 configurable 0 to ±10 V
  • Digital inputs: 8, 24 V DC, positive or negative logic
  • Digital output: 1 assignable, usable as Pulse Train Output (PTO)
  • Analog outputs: 2, configurable 0–10 V or 0/4–20 mA
  • Relay outputs: 3 total; 1 NO/NC plus 2 NO
  • Safety inputs: 2 for STO function
  • Expansion: up to 3 extra I/O modules
  • Operating temperature: -15 to +50 °C standard; derating up to 60 °C
  • Storage temperature: -40 to +70 °C
  • Humidity: 5 to 95% non-condensing
  • Altitude: no derating up to 1000 m; derate 1% per extra 100 m up to 3000 m
  • Protection rating: IP20 / UL Type 1
  • EMC filter: C2 for U07N4 to D45N4; C3 above D45N4
  • SCCR: 50 kA maximum
  • Power dissipation: 2987 W ND; 2436 W HD at nominal load
  • Minimum air flow: 600 m³/h
  • Dimensions (H×W×D): 1205 x 320 x 393 mm
  • Weight: 104 kg (229 lb)
  • Terminal torque: 27 N·m main; 13.5 N·m control
  • Minimum brake resistor: 1.9 Ω
  • Interference immunity: Achilles Level 2 certified for cyber security

Installation Guide

  • First, keep 250 mm clearance above and below the drive.
  • Also keep 100 mm clearance in front for airflow.
  • Then mount the unit vertically on a wall or in a cabinet.
  • After that, use the built-in brake chopper with an external resistor of 1.9 Ω minimum.
  • Next, tighten main terminals to 27 N·m.
  • Likewise, tighten control terminals to 13.5 N·m.
  • Meanwhile, follow EMC rules from the installation manual NHA80932.
  • Finally, wire the STO inputs to your safety relay for SIL3 protection.

Commissioning and Maintenance

  • The drive offers open-loop sensorless flux vector control for fast setup.
  • For higher precision, switch to closed-loop with encoder.
  • In addition, use the built-in Ethernet port for quick PC tool access.
  • Also check fan and airflow every 6 months in dusty sites.
  • Then inspect brake resistor wiring at each service interval.
  • After that, review fault logs through the Modbus port or HMI.
  • Finally, clean heatsink fins when ambient exceeds 40 °C.

Compatibility Notes

  • It works with asynchronous motors in standard or optimized torque mode.
  • Moreover, it supports synchronous PM motors in open or closed loop.
  • It also supports synchronous reluctance motors with vector control.
  • Additionally, built-in protocols include EtherNet/IP, Modbus TCP and Modbus RTU.
  • For fieldbus needs, optional modules cover PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT and POWERLINK.
  • In addition, the drive accepts up to 3 I/O expansion modules for more analog and digital points.
  • Finally, it pairs with Schneider Altivar Process accessories and braking resistors.

Certifications

  • UL 508C and UL 61800-5-1
  • EN/IEC 61800-3 category C2/C3
  • EN/IEC 61800-5-1
  • IEC 61508 for functional safety
  • IEC 13849-1 Cat. PL e
  • Achilles Level 2 cyber security
  • REACH compliance
  • SEMI F47-0706 for semiconductor fabs
  • Environmental class 3C3 / 3S3 / 3M3 per IEC 60721-3-3

Package Contents

  • 1 x ATV930C13N4 drive unit
  • 1 x printed installation manual
  • 1 x safety information sheet
  • Terminal covers and mounting hardware
  • Note: braking resistor and fieldbus module sold separately

FAQ

  • Q: Can this drive run a 132 kW motor in heavy duty mode?
    • A: No. Use heavy duty only up to 110 kW. Normal duty handles the 132 kW motor with 120% overload.
  • Q: Do I need to buy a braking resistor?
    • A: Yes. The drive has a built-in chopper, but the resistor itself is external. Therefore, use at least 1.9 Ω.
  • Q: How do I connect the drive to a plant network?
    • A: Use the dual-port Ethernet switch for EtherNet/IP or Modbus TCP. Meanwhile, the RJ45 serial port handles Modbus RTU.
  • Q: What is the highest ambient temperature for full power?
    • A: 50 °C. Above that, derate the drive up to 60 °C per the catalog.
  • Q: Does this model support encoder feedback?
    • A: Yes. Closed-loop vector control is available for asynchronous and PM motors with an encoder option.
  • Q: From experience, what causes nuisance trips at startup?
    • A: Loose main terminals or a missing brake resistor often trip the drive. First torque terminals to 27 N·m and then check resistor wiring.
  • Q: How often should I clean the heatsink in a foundry?
    • A: In dusty air, check monthly. Clogged fins raise internal temperature and shorten capacitor life.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV930C13N4 Schneider Altivar Process Drive 132 kW ND/HD VSD”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart