Product details
Product Overview
- Model ATV930C13N4 is a high-performance variable speed drive from Schneider Electric.
- It belongs to the Altivar Process ATV930 series, built for heavy industrial use.
- Moreover, this three-phase drive supports 380 to 480 V supplies with dual ND/HD ratings.
- In addition, a built-in dynamic brake transistor saves space and wiring time.
- For example, you can choose 132 kW (200 HP) in Normal Duty with 120% overload for 60 s.
- Alternatively, pick 110 kW (150 HP) in Heavy Duty with 150% overload for 60 s.
- It controls asynchronous motors in open or closed loop vector mode.
- In addition, it drives synchronous PM and reluctance motors with encoder feedback.
- Furthermore, an integrated STO safety function reaches SIL3 and Cat. PL e.
- Also, a built-in Ethernet dual-port switch and Modbus serial port cut extra hardware.
- Meanwhile, one option slot accepts PROFINET, EtherCAT, CANopen and more.
- As a result, this drive suits pumps, fans, conveyors and process lines in demanding plants.
Technical Specifications
- Brand: Schneider Electric
- Model: ATV930C13N4
- Series: Altivar Process ATV930
- Module type: Three-phase variable speed drive
- Supply voltage: 380 to 480 V three-phase, -15% to +10%, 50/60 Hz
- Motor power ND: 132 kW (200 HP)
- Motor power HD: 110 kW (150 HP)
- Output frequency: 0.1 to 599 Hz
- Switching frequency: 4 kHz nominal for U07N4 to D45N4; 2.5 kHz for D55N4 to C22N4
- ND input current: 237 A at 380 V; 213 A at 480 V
- ND continuous output: 250 A at nominal switching frequency
- ND transient output: 300 A for 60 s (120% of In)
- HD input current: 201 A at 380 V; 165 A at 480 V
- HD continuous output: 211 A at nominal switching frequency
- HD transient output: 317 A for 60 s (150% of In)
- Analog inputs: 3 total; 2 configurable 0–10 V or 0/4–20 mA with PTC/PT100/PT1000/KTY84 probe input; 1 configurable 0 to ±10 V
- Digital inputs: 8, 24 V DC, positive or negative logic
- Digital output: 1 assignable, usable as Pulse Train Output (PTO)
- Analog outputs: 2, configurable 0–10 V or 0/4–20 mA
- Relay outputs: 3 total; 1 NO/NC plus 2 NO
- Safety inputs: 2 for STO function
- Expansion: up to 3 extra I/O modules
- Operating temperature: -15 to +50 °C standard; derating up to 60 °C
- Storage temperature: -40 to +70 °C
- Humidity: 5 to 95% non-condensing
- Altitude: no derating up to 1000 m; derate 1% per extra 100 m up to 3000 m
- Protection rating: IP20 / UL Type 1
- EMC filter: C2 for U07N4 to D45N4; C3 above D45N4
- SCCR: 50 kA maximum
- Power dissipation: 2987 W ND; 2436 W HD at nominal load
- Minimum air flow: 600 m³/h
- Dimensions (H×W×D): 1205 x 320 x 393 mm
- Weight: 104 kg (229 lb)
- Terminal torque: 27 N·m main; 13.5 N·m control
- Minimum brake resistor: 1.9 Ω
- Interference immunity: Achilles Level 2 certified for cyber security
Installation Guide
- First, keep 250 mm clearance above and below the drive.
- Also keep 100 mm clearance in front for airflow.
- Then mount the unit vertically on a wall or in a cabinet.
- After that, use the built-in brake chopper with an external resistor of 1.9 Ω minimum.
- Next, tighten main terminals to 27 N·m.
- Likewise, tighten control terminals to 13.5 N·m.
- Meanwhile, follow EMC rules from the installation manual NHA80932.
- Finally, wire the STO inputs to your safety relay for SIL3 protection.
Commissioning and Maintenance
- The drive offers open-loop sensorless flux vector control for fast setup.
- For higher precision, switch to closed-loop with encoder.
- In addition, use the built-in Ethernet port for quick PC tool access.
- Also check fan and airflow every 6 months in dusty sites.
- Then inspect brake resistor wiring at each service interval.
- After that, review fault logs through the Modbus port or HMI.
- Finally, clean heatsink fins when ambient exceeds 40 °C.
Compatibility Notes
- It works with asynchronous motors in standard or optimized torque mode.
- Moreover, it supports synchronous PM motors in open or closed loop.
- It also supports synchronous reluctance motors with vector control.
- Additionally, built-in protocols include EtherNet/IP, Modbus TCP and Modbus RTU.
- For fieldbus needs, optional modules cover PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT and POWERLINK.
- In addition, the drive accepts up to 3 I/O expansion modules for more analog and digital points.
- Finally, it pairs with Schneider Altivar Process accessories and braking resistors.
Certifications
- UL 508C and UL 61800-5-1
- EN/IEC 61800-3 category C2/C3
- EN/IEC 61800-5-1
- IEC 61508 for functional safety
- IEC 13849-1 Cat. PL e
- Achilles Level 2 cyber security
- REACH compliance
- SEMI F47-0706 for semiconductor fabs
- Environmental class 3C3 / 3S3 / 3M3 per IEC 60721-3-3
Package Contents
- 1 x ATV930C13N4 drive unit
- 1 x printed installation manual
- 1 x safety information sheet
- Terminal covers and mounting hardware
- Note: braking resistor and fieldbus module sold separately
FAQ
- Q: Can this drive run a 132 kW motor in heavy duty mode?
- A: No. Use heavy duty only up to 110 kW. Normal duty handles the 132 kW motor with 120% overload.
- Q: Do I need to buy a braking resistor?
- A: Yes. The drive has a built-in chopper, but the resistor itself is external. Therefore, use at least 1.9 Ω.
- Q: How do I connect the drive to a plant network?
- A: Use the dual-port Ethernet switch for EtherNet/IP or Modbus TCP. Meanwhile, the RJ45 serial port handles Modbus RTU.
- Q: What is the highest ambient temperature for full power?
- A: 50 °C. Above that, derate the drive up to 60 °C per the catalog.
- Q: Does this model support encoder feedback?
- A: Yes. Closed-loop vector control is available for asynchronous and PM motors with an encoder option.
- Q: From experience, what causes nuisance trips at startup?
- A: Loose main terminals or a missing brake resistor often trip the drive. First torque terminals to 27 N·m and then check resistor wiring.
- Q: How often should I clean the heatsink in a foundry?
- A: In dusty air, check monthly. Clogged fins raise internal temperature and shorten capacitor life.
















There are no reviews yet.