Product details
Product Overview
- Model ATV610C31N4 is a variable speed drive from Schneider Electric.
- Moreover, it belongs to the Easy Altivar 610 series for pumps and fans.
- Rated power is 315 kW (500 HP) in normal duty.
- Supply is 380…460 V three-phase at 50/60 Hz.
- Also, an integrated C3 EMC filter cuts wiring effort and panel space.
- The plain text display terminal VW3A1113 ships with the drive.
- Standard protection is IP00, but an IP21 kit is optional.
- Frame size is 8A, and the unit weighs 180 kg.
- Open-loop control covers async, sync, PMSM and reluctance motors.
- For example, quadratic U/f (UFQ) suits variable-torque fan and pump loads.
Technical Specifications
- Brand and model
- Brand: Schneider Electric.
- Model: ATV610C31N4.
- Series: Easy Altivar 610.
- Also, the product type is AC frequency inverter.
- Power ratings
- Normal duty: 315 kW (500 HP) and 616 A continuous.
- Transient current is 678 A for 60 s.
- Heavy duty: 250 kW (400 HP) and 481 A continuous.
- Meanwhile, heavy duty transient reaches 722 A for 60 s.
- Overload is 110% for 60 s or 120% for 20 s in normal duty.
- However, heavy duty allows 150% for 60 s.
- Input and output
- Input current: 571 A at 380 V and 480 A at 460 V.
- Apparent power is 382.8 kVA at 460 V.
- Short-circuit rating is 50 kA prospective Isc.
- Output frequency range is 0.1…500 Hz.
- Also, switching frequency is 2…8 kHz, 2.5 kHz nominal.
- Control and measurement
- Control modes include STD, UF5, UFQ, SYNU and SRVC.
- Motor cable: 150 m shielded and 200 m unshielded.
- Therefore, fit an output filter above 50 m for safety.
- Input harmonics: a built-in DC choke lowers distortion.
- However, THDi below 10% needs the optional VW3A46xxx passive filter.
- I/O and communication
- Analog inputs: 3, software-configurable 0…10 V or 0…20 mA.
- Digital inputs: 6 at 24 V DC, and two can act as pulse inputs.
- Analog outputs: 2, configurable for voltage or current.
- Relay outputs: 3 with configurable logic.
- Ports: two RJ45 Modbus serial links, one field and one HMI.
- In addition, Slot A takes Extended I/O VW3A3203 or relay module VW3A3204.
- Slot A also accepts the PROFIBUS DP V1 module VW3A3607.
- Protocol is Modbus RTU on RS485, with codes from manual EAV64395.
- Environment and immunity
- Operating temperature: -10…+40 °C without derating.
- Also, operation up to +60 °C is possible with derating.
- Storage temperature range is -25…+70 °C.
- Humidity is 5…95%, without condensation.
- Altitude: 1000 m without derating, and up to 3000 m with derating.
- Chemical and mechanical class is 3C2 / 3S2 per IEC/EN 60721.
- Mechanical class is 3M3 on frames 1-6, while frames 7-8 follow 3C2/3S2.
- Moreover, conformal coating protects the electronic cards.
- Therefore, the relay supply must be Overvoltage Category II, or use an isolation transformer.
Installation Guide
- Mount the drive vertically within ±10° for correct cooling.
- Keep clearances of 200 mm top, 150 mm bottom and 10 mm front.
- Also, tighten power terminals to 41 N·m.
- The fan is field-replaceable in under 5 minutes with no special tools.
- Therefore, plan cabinet heat removal of 6285 W at nominal current.
- Use the IP21 kit where dust or touch safety matters.
- Finally, terminals PA/+ and PB accept an external braking resistor.
Setup and Maintenance
- The VW3A1113 terminal gives two-line plain text menus.
- Also, diagnostic menus MND and MDH show Modbus network and HMI status.
- Three analog inputs accept voltage, current, temperature probe or water level sensor signals.
- Software configuration sets each analog channel, so few parts are needed.
- Moreover, Slot A modules add I/O or fieldbus without a new drive.
- Conformal-coated boards resist harsh plant air.
Compatibility Notes
- It works with three-phase asynchronous and synchronous motors in open loop.
- Also, it supports PMSM (SYNU) and reluctance (SRVC) motor control.
- Modbus RTU runs over the RS485 link with A, B and SGND terminals.
- The HMI RJ45 port supports multidrop terminals, Harmony and Magelis panels, or a configuration loader.
- In addition, PROFIBUS DP V1 module VW3A3607 supports Profidrive and CiA402 profiles.
- Extended I/O module VW3A3203 and relay module VW3A3204 fit Slot A.
Certifications
- CE marking under the EMC directive.
- Also, CSA C22.2 No. 274 covers Canada.
- However, no UL listing appears in the official catalog or installation manual.
Packing List
- One ATV610C31N4 drive, frame 8A.
- One plain text display terminal VW3A1113.
- Also, an integrated C3 EMC filter, factory fitted.
- Installation manual EAV64381.
- Finally, the IP21 kit and expansion modules are optional, not included.
FAQ
- Can one drive run both a fan and a pump?
- Yes. The UFQ curve fits variable-torque loads like these.
- Therefore, set motor data first, then pick the curve in the drive menu.
- Do I need an extra filter to reach low harmonic levels?
- The DC choke helps, but THDi under 10% needs the VW3A46xxx passive filter.
- Also, size the filter for your actual load before you order.
- What length of motor cable works in practice?
- Up to 150 m shielded or 200 m unshielded is allowed.
- However, our panel team fits a dv/dt filter past 50 m to protect the winding.
- How do I read fault codes without a laptop?
- The VW3A1113 terminal lists active faults in plain text.
- Moreover, check menu MND when a network fault appears.
- Is the fan easy to swap on site?
- Yes. A technician can change it in under five minutes.
- Therefore, no special tools are needed, so downtime stays short.
- Can I add a fieldbus later?
- Yes. Slot A takes the PROFIBUS DP V1 module VW3A3607.
- Thus, you keep the same drive and just add the card.
- What should I check before power-up?
- Confirm 41 N·m on the power terminals.
- Also, check the ±10° mounting angle and the clearance gaps.
- Finally, verify the relay supply meets Overvoltage Category II.















There are no reviews yet.