Over 50,000 hot-selling automation module components.

ATV610C31N4 Schneider Easy Altivar 610 315 kW Pump Fan Drive

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: ATV610C31N4
Brands:

Product details

Product Overview

  • Model ATV610C31N4 is a variable speed drive from Schneider Electric.
  • Moreover, it belongs to the Easy Altivar 610 series for pumps and fans.
  • Rated power is 315 kW (500 HP) in normal duty.
  • Supply is 380…460 V three-phase at 50/60 Hz.
  • Also, an integrated C3 EMC filter cuts wiring effort and panel space.
  • The plain text display terminal VW3A1113 ships with the drive.
  • Standard protection is IP00, but an IP21 kit is optional.
  • Frame size is 8A, and the unit weighs 180 kg.
  • Open-loop control covers async, sync, PMSM and reluctance motors.
  • For example, quadratic U/f (UFQ) suits variable-torque fan and pump loads.

Technical Specifications

  • Brand and model
    • Brand: Schneider Electric.
    • Model: ATV610C31N4.
    • Series: Easy Altivar 610.
    • Also, the product type is AC frequency inverter.
  • Power ratings
    • Normal duty: 315 kW (500 HP) and 616 A continuous.
    • Transient current is 678 A for 60 s.
    • Heavy duty: 250 kW (400 HP) and 481 A continuous.
    • Meanwhile, heavy duty transient reaches 722 A for 60 s.
    • Overload is 110% for 60 s or 120% for 20 s in normal duty.
    • However, heavy duty allows 150% for 60 s.
  • Input and output
    • Input current: 571 A at 380 V and 480 A at 460 V.
    • Apparent power is 382.8 kVA at 460 V.
    • Short-circuit rating is 50 kA prospective Isc.
    • Output frequency range is 0.1…500 Hz.
    • Also, switching frequency is 2…8 kHz, 2.5 kHz nominal.
  • Control and measurement
    • Control modes include STD, UF5, UFQ, SYNU and SRVC.
    • Motor cable: 150 m shielded and 200 m unshielded.
    • Therefore, fit an output filter above 50 m for safety.
    • Input harmonics: a built-in DC choke lowers distortion.
    • However, THDi below 10% needs the optional VW3A46xxx passive filter.
  • I/O and communication
    • Analog inputs: 3, software-configurable 0…10 V or 0…20 mA.
    • Digital inputs: 6 at 24 V DC, and two can act as pulse inputs.
    • Analog outputs: 2, configurable for voltage or current.
    • Relay outputs: 3 with configurable logic.
    • Ports: two RJ45 Modbus serial links, one field and one HMI.
    • In addition, Slot A takes Extended I/O VW3A3203 or relay module VW3A3204.
    • Slot A also accepts the PROFIBUS DP V1 module VW3A3607.
    • Protocol is Modbus RTU on RS485, with codes from manual EAV64395.
  • Environment and immunity
    • Operating temperature: -10…+40 °C without derating.
    • Also, operation up to +60 °C is possible with derating.
    • Storage temperature range is -25…+70 °C.
    • Humidity is 5…95%, without condensation.
    • Altitude: 1000 m without derating, and up to 3000 m with derating.
    • Chemical and mechanical class is 3C2 / 3S2 per IEC/EN 60721.
    • Mechanical class is 3M3 on frames 1-6, while frames 7-8 follow 3C2/3S2.
    • Moreover, conformal coating protects the electronic cards.
    • Therefore, the relay supply must be Overvoltage Category II, or use an isolation transformer.

Installation Guide

  • Mount the drive vertically within ±10° for correct cooling.
  • Keep clearances of 200 mm top, 150 mm bottom and 10 mm front.
  • Also, tighten power terminals to 41 N·m.
  • The fan is field-replaceable in under 5 minutes with no special tools.
  • Therefore, plan cabinet heat removal of 6285 W at nominal current.
  • Use the IP21 kit where dust or touch safety matters.
  • Finally, terminals PA/+ and PB accept an external braking resistor.

Setup and Maintenance

  • The VW3A1113 terminal gives two-line plain text menus.
  • Also, diagnostic menus MND and MDH show Modbus network and HMI status.
  • Three analog inputs accept voltage, current, temperature probe or water level sensor signals.
  • Software configuration sets each analog channel, so few parts are needed.
  • Moreover, Slot A modules add I/O or fieldbus without a new drive.
  • Conformal-coated boards resist harsh plant air.

Compatibility Notes

  • It works with three-phase asynchronous and synchronous motors in open loop.
  • Also, it supports PMSM (SYNU) and reluctance (SRVC) motor control.
  • Modbus RTU runs over the RS485 link with A, B and SGND terminals.
  • The HMI RJ45 port supports multidrop terminals, Harmony and Magelis panels, or a configuration loader.
  • In addition, PROFIBUS DP V1 module VW3A3607 supports Profidrive and CiA402 profiles.
  • Extended I/O module VW3A3203 and relay module VW3A3204 fit Slot A.

Certifications

  • CE marking under the EMC directive.
  • Also, CSA C22.2 No. 274 covers Canada.
  • However, no UL listing appears in the official catalog or installation manual.

Packing List

  • One ATV610C31N4 drive, frame 8A.
  • One plain text display terminal VW3A1113.
  • Also, an integrated C3 EMC filter, factory fitted.
  • Installation manual EAV64381.
  • Finally, the IP21 kit and expansion modules are optional, not included.

FAQ

  • Can one drive run both a fan and a pump?
    • Yes. The UFQ curve fits variable-torque loads like these.
    • Therefore, set motor data first, then pick the curve in the drive menu.
  • Do I need an extra filter to reach low harmonic levels?
    • The DC choke helps, but THDi under 10% needs the VW3A46xxx passive filter.
    • Also, size the filter for your actual load before you order.
  • What length of motor cable works in practice?
    • Up to 150 m shielded or 200 m unshielded is allowed.
    • However, our panel team fits a dv/dt filter past 50 m to protect the winding.
  • How do I read fault codes without a laptop?
    • The VW3A1113 terminal lists active faults in plain text.
    • Moreover, check menu MND when a network fault appears.
  • Is the fan easy to swap on site?
    • Yes. A technician can change it in under five minutes.
    • Therefore, no special tools are needed, so downtime stays short.
  • Can I add a fieldbus later?
    • Yes. Slot A takes the PROFIBUS DP V1 module VW3A3607.
    • Thus, you keep the same drive and just add the card.
  • What should I check before power-up?
    • Confirm 41 N·m on the power terminals.
    • Also, check the ±10° mounting angle and the clearance gaps.
    • Finally, verify the relay supply meets Overvoltage Category II.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV610C31N4 Schneider Easy Altivar 610 315 kW Pump Fan Drive”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart