Product details
📦 ABB AI950N – temperature input module (S900 series)
- ABB AI950N (3KDE175523L9500) – 4‑channel isolated analog input for RTD, TC, mV.
- Part of S900 I/O system; designed for safe area installation (non‑hazardous).
- Supports Pt100, Pt1000, Ni100 in 2/3/4‑wire, plus thermocouples B,E,J,K,L,N,R,S,T,U and millivolt.
- Channel‑to‑channel galvanic isolation, bus isolation, and input/power separation.
- Hot swap & hot configuration in run – no process interruption.
- Redundant power and communication options (system level).
- Extended diagnostics with FDT/DTM, wire break / short detection.
⚙️ technical specifications (AI950N) – tree structure
- ABB AI950N – 3KDE175523L9500
- type – analog input module, 4 channels, isolated
- measurement ranges
- RTD (Ω)
- Pt100, Pt1000, Ni100
- 0…3 kΩ (2/3/4‑wire)
- thermocouple (mV)
- B, E, J, K, L, N, R, S, T, U
- ±100 mV, ±1000 mV direct
- RTD (Ω)
- accuracy / linearity – ±0.1% F.S. typical | resolution 16 bit
- cold junction
- internal (on‑board sensor)
- external (Pt100)
- frequency response – 10 Hz (programmable filter)
- environmental tolerance
- temperature: -20°C … +60°C
- humidity: ≤93% @40°C, non‑condensing
- corrosive atmosphere: ISA‑S71.04 G3 coated
- isolation & immunity
- channel/input/bus: 500 V AC/DC
- ESD / surge protection (IEC)
- diagnostics
- wire break detection
- sensor short detection
- under/over range
- LED status per channel
- physical
- H×W×D: 104×20×104 mm | weight 0.13 kg
🔧 installation guide – tree
- mounting
- snap‑on DIN rail (S900 backplane)
- safe area / Zone 2 variant available
- wiring
- spring terminals, 0.2 … 2.5 mm² (AWG 24…14)
- direct field wiring – no marshalling
- shield connection recommended for TC
- hot‑swap
- integrated disconnection lever
- replace during operation – no power down
🔍 diagnostics & maintenance ease – tree
- per‑channel diagnostics
- short & break detection
- reported via PROFIBUS DP + LED
- advanced tools
- FDT/DTM frame – parametric linearisation
- auto‑diagnostic log (overrange, cold‑junction failure)
- maintenance features
- LED per channel (power, comm, fault)
- no primary voltage interruption for replacement
✅ compatibility & certifications – tree
- communication
- PROFIBUS DP‑V1, up to 12 Mbit/s
- works with any DP master (Siemens, ABB, etc.)
- environmental certifications
- G3 coating (ISA‑S71.04)
- CE, RoHS (2011/65/EU), WEEE
- safety
- intrinsic safety: No (module itself non‑Ex)
- can be used behind barriers
📦 package / warranty / fast delivery – tree
- package includes
- ABB AI950N module (3KDE175523L9500)
- connector set, quick start guide
- warranty
- 12‑month against defects
- original ABB sealed
- shipping
- FedEx, UPS, DHL – tracked & insured
- express 2‑5 days worldwide
🏭 typical applications – tree
- process industries
- chemical reactors, oil & gas, power generation
- HVAC, furnace control
- machinery
- plastic/rubber, multi‑sensor monitoring
- system integration
- S900 cabinet retrofit, eliminates marshalling
- high common‑mode environments
❓ FAQ – expert insights (tree)
- Q: Can AI950N read both Pt100 and thermocouple on same module?
- A: Yes, each of the 4 channels is independently configurable for RTD, TC, or mV. Mix types freely.
- Q: My plant has corrosive gases. Is this module protected?
- A: Absolutely. All components meet ISA‑S71.04 G3 severity level – standard coating.
- Q: How do I choose between internal and external cold junction?
- A: Use internal CJC for simplicity (0.5°C accuracy). For high precision with many thermocouples, connect external Pt100 CJC sensor.
- Q: Does it support HART? The description says “HART Yes”?
- A: The AI950N itself is HART‑capable (analog + HART pass‑through) when used with appropriate coupler – but note it’s primarily a temperature input. For pure HART instruments, use AI930 series.
- Q: Buying guide – which variant do I need: AI950N vs AI950?
- A: AI950N is the standard safe‑area version (G3 coated). AI950 (without N) is for Zone 2 installation. Choose based on your hazardous area classification. Most projects use AI950N.
- Q: Can I replace the module while the backplane is live?
- A: Yes, hot‑swap is supported thanks to mechanical disconnection levers. No arc, no power interruption.
- Q: What does the suffix “N” stand for?
- A: “N” indicates safe area (non‑hazardous) and G3 coated. No “N” = Zone 2 approval.
📬 contact & inquiries
- 📧 sales@powergearx.com
- 📞 +86 180 3000 5825 (WhatsApp)
- For volume discounts, technical support, or expedited shipping – reach out directly.















There are no reviews yet.