Product details
Product Overview
- ADV151-E50 – a 32‑channel digital input module from Yokogawa.
- Part of the ADV151 series for reliable field signal acquisition.
- Supports sink or source wiring for flexible system design.
- Compact, rugged, and built for industrial control cabinets.
Key Features
- 32 digital inputs – 24 V DC, sink/source compatible.
- Three operation modes – status, pushbutton, and SOE capture.
- Fast response – 8 ms for status input; 25 Hz max for pushbutton.
- High isolation – 2 kV AC (input‑system), 500 V AC (between commons).
- Flexible connection – pressure clamp, dedicated cable, or MIL connector.
- SOE support – captures time‑stamped events for diagnostics.
- Low power – draws only 500 mA at 5 V DC.
Technical Specifications
- Brand – Yokogawa
- Model – ADV151-E50
- Series – ADV151
- Type – Digital input module
- Channels – 32
- Rated voltage – 24 V DC (sink/source)
- ON voltage range – 18…26.4 V DC
- OFF voltage – ≤5.0 V DC
- Input current – 4.1 mA ±20 % per channel
- Max allowable voltage – 30.0 V DC
- Withstanding voltage – 2 kV AC (input‑system), 500 V AC (commons, per 16 ch)
- Response time (status) – ≤8 ms
- Min ON detection (pushbutton) – 20 ms
- Max ON/OFF cycle – 25 Hz
- Current consumption – 500 mA at 5 V DC
- Weight – 0.3 kg
- Connection types – Pressure clamp, dedicated AKB331 cable, MIL connector
- Suffix codes – E (SOE), 5 (no status display, non‑explosion), 0 (basic)
- Options – /D5A00 (KS Cable Interface Adapter)
Functions & Modes
- Status input – Reads ON/OFF state of field devices.
- Pushbutton input – Counts edges from momentary switches.
- SOE input – Captures Sequence of Events with timestamps.
Environmental & Certifications
- Operating temp – 0…55 °C (typical, refer to manual for derating).
- Storage temp – -20…70 °C.
- Humidity – 5…95 % non‑condensing.
- IP rating – IP20 (with front cover).
- Pollution degree – 2.
- Altitude – ≤2000 m.
- Vibration – 1 gn (10‑150 Hz).
- Shock – 15 gn for 11 ms.
- Standards – IEC 61131‑2, UL 508, CSA C22.2.
- Certifications – CE, UL, CSA (refer to model suffix).
Compatibility
- System – Yokogawa Centum VP, ProSafe‑RS, or STARDOM.
- Backplane – FCS (Field Control Station) or RIO modules.
- Cables – AKB331 dedicated cable or MIL‑type ribbon cable.
Installation & Maintenance
- Mounting – Insert into FCS/RIO base (rack).
- Wiring – Use pressure clamp terminals for tool‑free connection.
- Configuration – Set via engineering software (e.g., CENTUM VP).
- Diagnostics – SOE data and status LEDs help troubleshooting.
Packaging & Delivery
- Includes – 1 ADV151-E50 module, terminal block (optional).
- Warranty – 12 months against manufacturing defects.
- Shipping – 12‑24 hours via FedEx, UPS, or DHL.
Expert Review
- Manager’s Insight: “The ADV151-E50 delivers high channel density with SOE capability—ideal for critical alarm monitoring. Its 2 kV isolation and flexible wiring options make it a top choice for DCS upgrades.”
Applications
- Best for – Process automation, power plants, oil & gas, and water treatment.
- Connects to – Limit switches, proximity sensors, pushbuttons, and relay contacts.
- Used in – DCS remote I/O racks and safety shutdown systems.
Comparison
- ADV151-E50 vs. ADV551-P50 – ADV151 is digital input; ADV551 is digital output. Choose based on signal direction.
- ADV151-E50 vs. ADV151-E00 – E50 includes SOE; E00 does not. For event‑logging, pick E50.
- ADV151-E50 vs. AAV141-S00 – AAV141 is analog input. Use ADV151 for discrete signals only.
- Compare details: Yokogawa DCS Series
FAQ
- Q: What input voltage does this module accept?
A: 24 V DC, with ON from 18 V to 26.4 V. - Q: Can I wire both sink and source sensors?
A: Yes, the module supports both sink and source wiring. - Q: What is the response time for status input?
A: 8 ms or less. - Q: How do I connect the module to my system?
A: Use pressure clamp terminals, AKB331 cable, or MIL connector. - Q: What does the “E50” suffix mean?
A: “E” = with SOE capture; “5” = without status display; “0” = basic type. - Q: Is the module hot‑swappable?
A: Yes, in most Yokogawa systems supporting online replacement. - Q: What is the maximum frequency for pushbutton input?
A: 25 Hz (minimum ON time 20 ms). - Q: What is the warranty period?
A: 12 months from purchase. - Q: How fast is delivery?
A: We ship within 12‑24 hours via FedEx, UPS, or DHL.
Selection Guide
- Choose ADV151-E50 if:
- You need 32 digital inputs for a DCS system.
- You require SOE (Sequence of Events) for diagnostics.
- You want flexible wiring options (clamp, cable, or MIL).
- Consider other models if:
- You need fewer channels – check ADV151‑E10 (16‑channel).
- You don’t need SOE – choose ADV151‑E00 (basic).
- You need explosion protection – select suffix “8” instead of “5”.
- Pro tip: For alarm monitoring, choose the SOE version—it helps trace intermittent faults.