Product details
Product Highlights
- ABB PSTX470-600-70 – 470 A softstarter for 208–600 V AC motors
- Control supply: 100–250 V AC, 50/60 Hz (24 V DC optional)
- Built‑in bypass saves energy and cuts installation time
- Detachable IP66 graphic display – easy to program outdoors
- Torque control, kickstart, pump cleaning, and emergency mode
Core Technical Data
- Brand: ABB
- Model: PSTX470-600-70 (1SFA898116R7000)
- Rated current (Ie): 470 A in‑line / 814 A inside delta
- Rated power @400 V: 250 kW in‑line / 450 kW inside delta
- Rated power @500 V: 315 kW in‑line / 600 kW inside delta
- Voltage range: 208–600 V AC main, 100–250 V AC control
- Frequency: 50/60 Hz
- Starting capacity: 4× Ie for 10 seconds
- Current limit: 1.5–7.5× Ie adjustable
- Ramp time: 1–120 s (start/stop)
- Initial voltage: 10–99 %; step‑down 100–10 %
- Analog outputs: 0–10 V, 0–20 mA, 4–20 mA
- Protection: IP00 (main terminals)
- Temperature: –25…+60 °C operation, –40…+70 °C storage
- Weight: 25 kg; dimensions 361×493×282 mm
Measurement & Performance
- Range: 208–600 V AC – covers global voltages
- Frequency response: stable at 50 or 60 Hz
- Sensitivity: precise current limit from 1.5 to 7.5× Ie
- Linearity: smooth torque or voltage ramp reduces shock
- Resolution: digital settings in 1 % steps
- Ambient tolerance: works from –25 °C to +60 °C
- Immunity: EMC hardened for industrial noise
Installation & Commissioning
- Main terminals: bar type – hole Ø8.5 mm
- Control wiring: rigid 1×2.5 mm²
- Torque: main 35 N·m, control 0.5 N·m
- Built‑in bypass reduces heat and saves panel space
- Detachable graphic display with IP66 rating – outdoor ready
- LED status: green (ready/running), yellow (protection), red (fault)
Maintenance & Service
- Integrated overload and fault relays simplify diagnostics
- Analog outputs enable remote monitoring of current
- Run, bypass, and fault signal relays are standard
- Event log and real‑time clock aid troubleshooting
- No external overload relay needed – fully self‑protected
Communication & Compatibility
- Built‑in Modbus RTU as standard
- Optional ANYBUS modules for Profinet, Profibus, Ethernet/IP, Modbus TCP, BACnet, etc.
- Inside delta connection reduces line current by ~42 %
- Works with all 3‑phase AC motors
- Service factor 100 % for standard duty
Protection & Safety
- Electronic overload, earth fault, under/over voltage
- Current imbalance, locked rotor, and phase reversal protection
- PT‑100 and PTC inputs for motor thermal monitoring
- Bypass open, fieldbus failure, and HMI failure protection
- User‑defined protection profiles available
Certifications
- CE, CCC, CQC, and DNV certified
- RoHS and REACH compliant
- ETIM 7/8/9: EC000640 – Soft starter
- WEEE category 5 – small equipment
Package Contents
- 1× ABB PSTX470‑600‑70 softstarter
- Mounting hardware and terminal bars
- Quick start guide and installation manual (digital)
- Detachable graphic display with IP66 cover
Warranty & Shipping
- 12‑month warranty against defects in material and workmanship
- Dispatch: within 12–24 hours after order
- Carriers: FedEx, UPS, DHL – with tracking
Expert Review
- “The PSTX470 handles heavy loads with ease. Its torque control and built‑in bypass reduce mechanical stress and energy waste. A top pick for large pumps and fans.” – Senior Application Engineer
Manager‘s Insight
- “For 250–450 kW motors, this softstarter offers unmatched flexibility. The IP66 display and wide communication options make it ideal for global projects. Strong value for money.” – Product Line Manager, PowergearX
Ideal Equipment & Applications
- Large centrifugal and submersible pumps
- High‑capacity fans and blowers
- Heavy‑duty compressors (screw and reciprocating)
- Conveyor belts, crushers, and mills
- Mixers, extruders, and shredders
Target Industries
- Water & wastewater treatment plants
- HVAC for large commercial buildings
- Mining, aggregates, and cement
- Food & beverage processing lines
- Automotive stamping and assembly
Frequently Asked Questions
- What is the maximum motor current for this unit?
470 A in‑line or 814 A inside delta. - Can I use this with a 480 V motor?
Yes, the main circuit accepts 208–600 V AC. - What communication protocols are supported?
Modbus RTU is built‑in; optional ANYBUS modules add Profinet, Ethernet/IP, BACnet, and more. - Is the display removable and outdoor‑rated?
Yes, the graphic display is detachable and rated IP66 for outdoor use. - How many starts per hour are possible?
Up to 30 starts at 3.5× Ie for 7 s with 50 % duty cycle.
Buying Guide & Selection Tips
- Select PSTX470 for motors up to 470 A (in‑line) or 814 A (delta).
- At 400 V, it delivers 250 kW in‑line and 450 kW inside delta – ideal for large motors.
- Inside delta reduces cable size and contactor cost – a smart upgrade.
- Check control supply: 100–250 V AC or 24 V DC.
- For harsh environments, the IP66 display and wide temperature range (–25…+60 °C) are key.
- Use the built‑in emergency mode for fire pumps and critical processes.
Compare with Similar Models
- ABB PSTX370-600-70 – 370 A, 200 kW @400 V, torque control + bypass
- ABB PSTX470-600-70 – 470 A, 250 kW @400 V, higher power
- ABB PST250-600-70 – 250 A, 132 kW @400 V, basic soft start
- ABB PST300-600-70 – 300 A, 160 kW @400 V, with inside delta
Contact Information
- Sales Inquiries: sales@powergearx.com
- Phone / WhatsApp: +86 18030005825
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/














There are no reviews yet.