Product details
ABB PM891K01 3BSE053241R1 Processor Unit
Powergear X Automation presents a fast and stable industrial CPU for the ABB 800xA platform.
Core Highlights
- The PM891K01 runs a sharp 450 MHz processor.
- The module offers 256 MB memory with 208 MB for user tasks.
- The unit delivers a fast 0.043 ms logic execution time.
- The processor supports 2 Ethernet channels at 10/100 Mbit/s.
- It fits ABB 800xA 6.0.2 and later versions.
Technical Data Summary
- CPU Type: MPC8270 with smooth data handling.
- Flash storage: 16 MB for firmware.
- Power supply: 24 V DC (19.2–30 V DC).
- Power use: 660–750 mA with 15.8–18 W dissipation.
- CEX bus load: up to 12 modules.
- Event queue supports up to 3000 signals per OPC client.
- Transmission rate: 36–86 events/sec, 113–143 data messages/sec.
- Real-time sync accuracy: 1 ms between AC800M units.
- I/O capacity: up to 84 modules with optical Modulebus.
Environmental Strength
- Operating range: 0 to +55°C.
- Storage: −40 to +70°C.
- Humidity: 5–95% non-condensing.
- Shock and vibration tested per IEC rules.
- Protection class: IP20.
- Altitude rating: 2000 m.
- Corrosion level: G3.
Control & Communication
- Network protocols: MMS and IAC for smooth traffic.
- Recommended backbone: 100 Mbit/s switched Ethernet.
- RS-232C service port (COM4) with 9600 baud.
- Switch-over time (in redundant mode): max 10 ms.
Mechanical Information
- Size: 186 mm × 174 mm × 94 mm.
- Weight with base: 1.6 kg.
Included Items
- One PM891K01 3BSE053241R1 CPU module.
- One TB850 CEX-bus terminator.
- One TB853 RCU link terminator.
- No license included.
- 12-month warranty.
- Shipping by FedEx, UPS, or DHL.
Operational Notes
- Use in industrial zones with strong EMC rules.
- Follow ABB’s grounding guide for safe links.
- Use clean power lines for stable function.
FAQ
- Q: How often should I check the system load?
- A: Review CPU load weekly to avoid long scan times.
- Q: Does the module need cooling?
- A: Keep steady airflow and avoid dust buildup.
- Q: Can I mix older AC800M units with this CPU?
- A: Match firmware levels to avoid sync errors.
- Q: What helps keep startup stable?
- A: Test flash integrity and check power lines often.
- Q: How do I improve Ethernet reliability?
- A: Use shielded cables and switch ports with low load.
Contact Information Inquiries:
sales@powergearx.com ,
+86 18030005825
Copyright © 2025 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
Partner: Ubest Automation Limited















There are no reviews yet.