Product details
Product Overview – 6EP1336-3BA10
- 6EP1336-3BA10 is a SITOP PSU8200 power supply.
- It delivers 24 V DC at 20 A output current.
- Input accepts 120-230 V AC or 110-220 V DC.
- This unit is stabilized and fully regulated.
- It suits industrial control panels and automation systems.
Key Features
- High efficiency – 94% typical, low power loss (31 W).
- Wide input range – 85…275 V AC or 88…350 V DC.
- Adjustable output – 24…28 V via potentiometer.
- Robust protection – short-circuit proof, overvoltage <31.8 V.
- Compact design – 90×125×125 mm, fits DIN rail.
Technical Specifications
- Brand: Siemens
- Model: 6EP1336-3BA10
- Series: SITOP PSU8200
- Type: Switched-mode power supply
- Input voltage (AC): 120…230 V (nominal), 85…275 V (range)
- Input voltage (DC): 110…220 V (nominal), 88…350 V (range)
- Output voltage: 24 V DC (adjustable 24…28 V)
- Output current: 20 A (rated), derating above +60 °C
- Efficiency: 94 % (typical)
- Power loss: 31 W (typical at full load)
- Hold-up time: ≥20 ms at 230 V AC
- Inrush current limit: ≤20 A at 25 °C
- Ripple (max): 100 mV, peak 200 mV
- Response delay: ≤1.5 s, soft-start no overshoot
- Short-circuit current: ~21.5 A (constant or latching)
- Overload capability: 150 % for 5 s/min
- LED indicators: Green (OK), Yellow (overload), Red (shutdown)
- Relay output: “24 V OK” – NO contact, 60 V DC / 0.3 A
Installation Guide
- Snap the unit onto a DIN rail (EN 60715 35×7.5/15).
- Connect input: L, N, PE – 0.2…4 mm² per terminal.
- Connect output: +, – – two terminals each, 0.2…4 mm².
- Leave 50 mm free space above and below for cooling.
- Use a 10 A circuit breaker (C-characteristic) for 1-phase.
Commissioning & Maintenance
- Check the green LED for output OK after power-up.
- Adjust output voltage with the built-in potentiometer.
- Yellow LED signals overload – reduce load or check fans.
- Red LED indicates latching shutdown – reset by power cycling.
- No routine maintenance needed; keep vents clear.
Compatibility
- Works with all 24 V DC loads up to 20 A.
- Parallel operation possible for up to 2 units (increased power).
- Compatible with buffer modules (accessory).
- Meets EN 61204-7 and EN 61558-2-16 safety standards.
Certifications & Approvals
- CE, UKCA, EAC, RCM – global market acceptance.
- UL/cULus Listed (File E197259) and CSA.
- Shipbuilding approvals – ABS, DNV.
- SEMI F47 – withstands voltage dips.
- Environmental Product Declaration available.
Package Contents
- 6EP1336-3BA10 power supply unit
- Quick start guide (multi-language)
- Warranty card (12 months)
Warranty & Shipping
- 12-month warranty – covers material and workmanship.
- 12-24 hour dispatch from our warehouse.
- Shipping via FedEx, UPS, or DHL with tracking.
Expert Review
- “This PSU delivers rock-solid 24 V even with fluctuating mains.” – Senior Power Engineer.
- “The 94% efficiency reduces panel heat and saves energy.” – Control System Integrator.
- “I like the adjustable output – it compensates for cable drops.” – Field Service Technician.
Manager’s Insight
- “Stock one model for both 120 V and 230 V regions – simplify logistics.”
- “The relay contact gives a remote alarm, great for unmanned sites.”
- “For critical loads, parallel two units for N+1 redundancy.”
Applicable Devices & Applications
- Devices: PLCs, I/O racks, sensors, actuators, HMI panels.
- Applications: Factory automation, process control, machine tools, conveyor systems.
- Ideal for marine, industrial, and commercial environments.
- Supports 24 V DC loads up to 480 W (20 A).
Frequently Asked Questions
- Can I use this with a 110 V DC input?
Yes, the input range covers 88…350 V DC, so 110 V DC is fine.
- What happens if the output is shorted?
The unit limits current to ~21.5 A – either constant or latching (selectable).
- How do I reset a latching shutdown?
Turn off the input power for 10 seconds, then restart.
- Is derating needed at high temperatures?
Yes, above +60 °C, reduce load by 3% per °C up to +70 °C.
- Can I mount it on a wall?
No, this model is only for DIN rail mounting.
Selection Guide – Experience-Based Tips
- For long cable runs, set output to 28 V to compensate for voltage drop.
- If you expect frequent overloads, choose the “constant current” mode.
- For sensitive electronics, add a buffer module to bridge short power dips.
- Calculate total load current – do not exceed 20 A continuously.
- For 2-phase operation, use a 2-pole circuit breaker as recommended.