Product Overview
The Allen-Bradley 440N-Z21SS2HN is a non-contact safety interlock switch. It belongs to the Guardmaster 440N SensaGuard series by Rockwell Automation. This rectangular plastic switch uses a standard code actuator. It suits machine guarding tasks that need high safety levels and washdown protection.
The switch offers 2 N.C. safety outputs and 1 N.O. auxiliary output. All outputs are solid-state. It reaches Cat. 4, PLe, SIL CL 3 ratings. The unit works on 24V DC. It carries IP66, IP67, and IP69K ratings. It fits food processing, packaging, and other harsh plants.
Technical Data
- Brand: Rockwell Automation
- Model: 440N-Z21SS2HN
- Series: Guardmaster 440N SensaGuard
- Product Type: Rectangular plastic non-contact safety switch with standard code actuator
- Sensing Range (Assured ON): 15 mm (0.59 in.)
- Sensing Range (Assured OFF): 25 mm (0.98 in.)
- Contact Configuration: 2 N.C. safety outputs, 1 N.O. auxiliary output, solid-state
- Operating Voltage: 24V DC, 10%/-15%, Class 2 SELV or PELV
- Outputs (OSSD): Safe state de-energized (2 x PNP, 0V), AUX energized (1 x PNP, 24V). Run state energized (2 x PNP, 24V), AUX de-energized (1 x PNP, 0V)
- Load Current: 200 mA maximum
- Voltage Drop: less than 1.5V
- Response Time (Off): 45 ms
- No-load Supply Current: less than 50 mA
- Frequency of Operating Cycle: 0.25 Hz
- Utilization Category: DC-12 and DC-13, 24V, 200 mA
- Temperature Range: -25 to +70°C (-13 to +158°F)
- Operating Humidity: 5 to 95% relative
- Environmental Tolerance: IP66, IP67, IP69K washdown rating
- Shock and Vibration: IEC 60068-2-27, 30 g, 11 ms; IEC 60068-2-6, 10 to 55 Hz
- Pollution Degree: IEC 60947-1, degree 3
- Rated Impulse Withstand Voltage: 1 kV
- Interference Immunity: ESD 8 kV air discharge; radiated EMF 20V/m; EFT 2 kV/5 kHz; conducted immunity 20V
- Protection: Short circuit, overload, reverse polarity, overvoltage, loss of ground
- Connection Type: 6-inch pigtail with 8-pin Micro (M12) connector
- Diagnostics: LED door indication and margin indication
- Case Material: Polycarbonate for sensor and actuator
- Safety Ratings: IEC 60947-5-3, Cat. 4, PLe, Type 4 interlocking, SIL CL 3
- Series Connection: Unlimited switches in series, see timing diagram
Installation Guide
- Mount the sensor on a flat, rigid surface.
- Align the actuator with the sensor face.
- Keep the gap below 15 mm for assured ON.
- Keep the gap above 25 mm for assured OFF.
- Use the 8-pin M12 connector for wiring.
- Connect to a 24V DC SELV or PELV supply.
- Do not exceed 200 mA load current.
- Check the LED door and margin indicators after mounting.
Setup and Maintenance Convenience
- The LED indicators show door status and sensing margin.
- Margin indication helps spot misalignment early.
- Solid-state outputs have no moving contacts to wear.
- The smooth plastic case resists washdown cleaning.
- Series wiring is unlimited for flexible cell design.
- Built-in protection cuts downtime from wiring faults.
Compatibility Notes
- Works with standard code actuators from the 440N SensaGuard line.
- Fits safety relays and controllers that accept PNP OSSD signals.
- Uses standard 8-pin M12 cordsets.
- Suits systems rated for Cat. 4, PLe, or SIL CL 3.
- Runs on common 24V DC machine power.
Certifications
- IEC 60947-5-3 safety standard
- Cat. 4, PLe per ISO 13849-1
- SIL CL 3 per IEC 62061
- Type 4 interlocking per ISO 14119
- IEC 61326-1 and IEC 61000-6-7 EMC compliance
- IP66, IP67, IP69K environmental ratings
Packing List
- 440N-Z21SS2HN sensor
- Standard code actuator
- 6-inch pigtail with 8-pin M12 connector
- Mounting hardware
- Installation instructions
FAQ
Q: What is the assured ON distance?
A: The assured ON distance is 15 mm. Keep the actuator within this gap for a valid safety signal.
Q: What is the assured OFF distance?
A: The assured OFF distance is 25 mm. The outputs turn off beyond this gap.
Q: How many safety outputs does it have?
A: It has 2 N.C. safety outputs and 1 N.O. auxiliary output. All are solid-state.
Q: Can I connect several switches in series?
A: Yes. The series connection is unlimited. Check the timing diagram for details.
Q: Does it survive washdown cleaning?
A: Yes. It holds IP66, IP67, and IP69K ratings. It suits food and beverage plants.
Q: What supply voltage does it need?
A: It needs 24V DC from a Class 2 SELV or PELV source. Tolerance is 10%/-15%.
Q: What is the response time?
A: The OFF response time is 45 ms. This helps safety circuits react fast.
Q: Which safety level does it reach?
A: It reaches Cat. 4, PLe, and SIL CL 3. It also meets Type 4 interlocking.
Q: Why does the margin LED blink?
A: A blinking margin LED means the actuator sits near the sensing limit. Adjust the gap to restore a strong signal.
Q: The safety outputs stay off after power-up. What should I check?
A: Check the actuator gap first. Then check the 24V supply and the M12 wiring. Also confirm the load is below 200 mA.
Q: How do I avoid nuisance stops on a vibrating machine?
A: Mount the sensor and actuator on rigid brackets. Keep the gap well under 15 mm. This holds the signal stable during shock and vibration.