Product details
Product Overview
- 440N-G02123 is a magnetic non-contact safety interlock switch from Allen-Bradley.
- It belongs to the Guardmaster Ferrogard FRS21 GD2 series by Rockwell Automation.
- The stainless steel housing resists impact, rust and washdown.
- Two N.C. safety contacts and one N.O. auxiliary contact handle guard monitoring.
- A standard actuator comes with the switch.
- The 3 m PVC cable speeds up wiring on site.
- The unit carries an IP68 rating for wet and dusty plants.
- This product is active and ready for new builds or spares.
Technical Data
- Brand: Allen-Bradley (Rockwell Automation)
- Model: 440N-G02123
- Series: Guardmaster Ferrogard FRS21 GD2
- Module type: Non-contact safety interlock switch
- Contact type: Reed
- Safety contacts: 2 N.C.
- Auxiliary contact: 1 N.O.
- Supply voltage: 24 VDC
- Switching current: 1 A maximum
- Actuation: Magnetic, non-contact
- Actuator: Standard type included
- Connection: 3 m PVC cable, fixed
- Housing material: Stainless steel
- Special features: None
- Temperature range: Follow the datasheet for the exact site limits
- Environmental resistance: IP68 dust and water protection
- Interference resistance: Reed design resists dust, dirt and stray light
- Measurement range, frequency response, sensitivity, linearity, resolution: Not applicable to this switch type
Installation Guide
- Mount the switch body on the fixed frame of the guard.
- Fit the standard actuator on the moving door.
- Keep the gap between switch and actuator within the datasheet range.
- Route the 3 m cable away from moving parts.
- Wire the two N.C. contacts into the safety circuit.
- Use the N.O. contact for status feedback only.
- Check alignment before you tighten the screws.
- Seal cable glands well to keep the IP68 rating.
Setup and Maintenance
- Test the switch with the door open and closed at each shift start.
- Clean the switch face to keep the magnetic gap stable.
- Check the actuator for looseness at each service visit.
- Inspect the cable jacket for cuts or crush marks.
- Replace the unit if the contacts fail a continuity test.
- No calibration is needed. The reed contacts work without setup.
Compatibility
- Works with standard Ferrogard actuators for the FRS21 series.
- Fits safety relays and safety controllers that accept N.C. inputs.
- The 24 VDC rating suits most machine control panels.
- The N.O. auxiliary contact links to PLC status inputs.
- Common in gate, guard door and hatch monitoring.
Certifications and Standards
- Built for machine safety interlock duties.
- Backed by Rockwell Automation and the Guardmaster brand.
- IP68 rating for harsh washdown and outdoor sites.
Packing List
- 1 x Allen-Bradley 440N-G02123 switch
- 1 x standard actuator
- 1 x 3 m PVC cable, pre-fitted
- 1 x document pack
FAQ
- Can I use this switch on a sliding gate?
- Yes. Keep the actuator gap tight and align both parts well.
- What does the N.O. contact do?
- It sends door status to a PLC. It is not a safety contact.
- Does dirt block the sensing?
- No. The reed design ignores dust, dirt and light.
- How much current can the contacts carry?
- Keep the load at or below 1 A at 24 VDC.
- Can I extend the cable?
- Yes, in a junction box. Keep the splice dry and shielded from strain.
- Do I need a safety relay?
- Most machines do. The two N.C. contacts feed the relay inputs.
- What if the machine will not start after fitting?
- Check the actuator gap first. Then test each N.C. contact for continuity.
- Is the switch good for washdown areas?
- Yes. The IP68 stainless steel body handles wet cleaning.
- How long does the switch last?
- Reed switches last for millions of cycles. Replace them after physical damage.
- Can I buy the actuator alone?
- Yes. Order the standard Ferrogard actuator as a spare part.
















There are no reviews yet.