Product details
Product Highlights
- Model 22A-A4P5H204 is a PowerFlex 4 AC drive from Allen-Bradley / Rockwell Automation.
- It takes single-phase 200…240 V AC input and gives 0.75 kW (1 HP) output at 4.5 A.
- Output is three-phase 0…230 V with a frequency range of 0…240 Hz.
- The replacement plate design fits right into existing panel cutouts.
- An integral brake IGBT is built in for fast stops.
- A built-in RS-485 DSI port supports Modbus RTU networking.
- This is a compact, low-cost choice for simple motor control.
Technical Data
- Brand and model
- Brand: Allen-Bradley (Rockwell Automation)
- Model: 22A-A4P5H204
- Series: PowerFlex 4 (22A)
- Type: AC adjustable-frequency drive
- Catalog code breakdown
- 22A = PowerFlex 4 family
- A = 240 V AC, single-phase
- 4P5 = 4.5 A output, 0.75 kW
- H = replacement plate, IP20 open type
- 2 = interface module code
- 0 = not filtered
- 4 = standard build
- Power and control
- Output power: 0.75 kW (1 HP)
- Continuous output: 4.5 A
- Carrier frequency: 2…16 kHz, default 4 kHz
- Overload: 150% for 60 s; 200% for 3 s
- Efficiency: 97.5% typical
- Speed regulation: ±2% with slip compensation
- Ramp times: 0…600 s, two sets
- Stop modes: Ramp, Coast, DC-Brake, Ramp-to-Hold, S Curve
- Inputs and outputs
- Digital inputs: 3 fixed + 2 programmable
- Analog input: 1, 0…10 V or 4…20 mA, DIP-selectable
- Relay output: 1 Form C, 3.0 A resistive at 30 V DC / 240 V AC
- Electrical
- Input range: 180…265 V AC, single-phase, 50/60 Hz
- Input current: 10.0 A, 2.25 kVA, 15 A fuse
- Power ride-through: 100 ms
- Overcurrent limit: 200% hardware, 300% trip
- Heat loss: 55 W total at rated load
- Environment
- Run temperature: -10…+50 °C for open type; +40 °C for NEMA 1
- Storage: -40…+85 °C
- Humidity: 0…95% non-condensing
- Shock: 15 g / 11 ms; vibration: 1 g, 5…2000 Hz
- Noise: 50 dBA at 1 m
- Altitude: 1000 m without derating
- Keep the air free of corrosive gas, vapor, or dust
- Physical
- Size: 175.0 × 104.8 × 94.0 mm overall
- Weight: 1.58 kg
- Frame: A
- Cooling: fan cooled
- Network and options
- Port: 1 × RS-485 DSI, up to 2 peripherals
- Protocol: Modbus RTU, codes 03, 06, 16
- Nodes: 1…247; speed: 1200…38400 bit/s
- Filters: use external L type 22-RF010-AL for CE
- NEMA 1 kit: 22-JBAA
- Brake resistor: 60 Ω min, AK-R2-091P500
Where It Fits
- Small conveyors and package handling lines
- Fans and blowers in light duty rooms
- Pumps for water supply and sumps
- Mixers and agitators on small tanks
- Machine tools and simple spindle drives
- Door and gate motion control
- Food and packing equipment in dry areas
- Retrofits where a plate drive drops into an old cutout
Install Guide
- Mount the plate into the panel cutout and fix the screws.
- Keep the heatsink clear so air can flow.
- Set input voltage with the DIP switches before power-up.
- Use a 15 A branch fuse or a listed motor protector.
- Add an external filter when CE limits apply.
- Wire the RS-485 link with terminating resistors at the ends.
- Add an external brake resistor for fast stops.
Setup and Care
- The LED keypad shows faults and settings on the spot.
- Set ramp and stop mode with simple parameters.
- Check the fan and heatsink at each service visit.
- Clear dust from the vents to avoid overheating.
- The plate design allows quick swap without rewiring the panel.
Certifications
- cULus Listed to UL 508C and CSA C22.2 No. 14
- CE: EMC 2014/30/EU and LVD 2014/35/EU
- KC mark: KCC-REM-RAA-22A
- IE2 efficiency under EU 2019/1781
- No Safe Torque Off and no seismic rating published
Packing List
- 22A-A4P5H204 replacement plate drive
- Fixed LED keypad
- Installation manual 22A-UM001L-EN-E
- Weight: 1.58 kg
FAQ
- Q: Will this drive run a three-phase motor from a single-phase line?
- A: Yes. It makes three-phase 0…230 V output from one-phase input.
- Q: Can I control it from a PLC over Modbus?
- A: Yes. The DSI port speaks Modbus RTU with codes 03, 06, and 16.
- Q: Do I need a separate filter for CE?
- A: Yes. This build has no internal filter. Add the L type unit.
- Q: From field practice, why does the drive trip on long motor cables?
- A: Cable length adds capacitance. Keep runs short and fit a filter.
- Q: From field practice, what causes a fast stop to fault?
- A: The brake resistor is too small or the stop time is too short.
- Q: From field practice, how do I cut RF noise in a panel?
- A: Use shielded cable. Bond the shield at both ends to PE.













There are no reviews yet.