Product details
170ENT11001 Communication Adapter – Modicon Momentum Ethernet Module
170ENT11001 is a communication adapter from Schneider Electric’s Modicon Momentum series. This module moves data fast. It supports 10 or 100 Mbit/s. It also uses Ethernet TCP/IP. Therefore, it fits many industrial networks.
- Brand: Schneider Electric
- Model: 170ENT11001
- Series: Modicon Momentum
- Type: Ethernet TCP/IP communication adaptor
- Weight: 0.15 lb (0.07 kg) net
- Origin: FR
Technical Data (Core Specifications)
- Measurement Range: Not applicable (communication adapter)
- Frequency Response: 10/100 Mbit/s transmission rate
- Sensitivity: Not applicable
- Linearity: Not applicable
- Resolution: Not applicable
- Temperature Range:
- Operating: 0 to 60°C (non-condensing)
- Storage: -40 to 85°C (non-condensing)
- Environmental Tolerance: IP20 protection class, TC protective treatment
- Anti-interference: CRC-32 control parameter for data integrity
- Baud Rate: 10 or 100 megabits per second
- Protocol: Ethernet TCP/IP
- Access Method: Master/Slave, peer-to-peer (P2P)
- Cable Type: Shielded twisted pairs
- Ethernet Port: 100BASE-TX, RJ45 connector
- Devices per Segment: 0 to 32
- Topology: Star network, multi-drop
- Status Indicators: 4 LEDs (3 green, 1 yellow)
- Max Cable Distance: 3,280 feet (1,000 meters)
- Addressing: Unique IEEE global address, user-assigned IP
- Module Configuration: BOOTP server for IP parameters
- Fail State: Fail safe
Installation Guide
- Mount the 170ENT11001 on a DIN rail or panel.
- Use shielded twisted pair cable for best performance.
- Connect RJ45 to a 100BASE-TX port.
- Keep cable length under 1,000 meters between devices.
- Assign IP via BOOTP server or manually.
- Check 4 LED indicators for status.
- Operate within 0 to 60°C non-condensing area.
Commissioning and Maintenance Convenience
- BOOTP server makes IP setup simple.
- LEDs show power, link, activity, and error.
- CRC-32 checks data automatically.
- No special tools needed for wiring.
- Supports star and multi-drop topologies.
- Hot-swap not recommended during operation.
Compatibility Notes
- Works with Modicon Momentum automation platform.
- Connects to any 100BASE-TX Ethernet network.
- Supports up to 32 devices per segment.
- Uses standard IEEE global addressing.
- Compatible with master/slave and peer-to-peer systems.
Certifications and Compliance
- CE marked.
- IP20 degree of protection.
- TC protective treatment.
- EAN: 3595862034302
- GTIN: 3595862034302
Packing List
- 1 x 170ENT11001 communication adapter
- Package weight: 8.219 oz (233 g)
- Package dimensions: 6.000 cm x 18.300 cm x 26.100 cm
- No cable or software included.
Warranty and Shipping
- 12-month warranty from date of delivery.
- Ships within 12–24 hours after payment.
- Carriers: FedEx, UPS, DHL.
- Tracking number provided.
- Returnable: Yes (see policy).
Expert Review
The 170ENT11001 is a solid choice for Modicon Momentum users. It offers dual-speed Ethernet. Setup is easy with BOOTP. The IP20 rating suits clean cabinets. CRC-32 adds data safety. It handles up to 32 nodes per segment. The 1,000-meter range gives layout freedom. However, this adapter is not for harsh washdown areas. But for standard factory networks, it works well. It is a reliable, no-fuss Ethernet bridge.
Manager’s Insight
Most customers buy this module to add Ethernet to older Momentum racks. It solves the “no network port” problem fast. The 10/100 Mbit/s auto-negotiation saves time. We see low return rates. The main mistake is forgetting the BOOTP server. Buy this if you need simple TCP/IP connectivity. Skip it if you need IP67 or wireless. For the price, it is a cost-effective upgrade.
Best Fit Devices and Applications
- Modicon Momentum PLC racks
- Factory automation cells
- SCADA networks
- Peer-to-peer controller links
- Star or multi-drop Ethernet topologies
- Industrial control panels with IP20 environment
- Legacy systems needing Ethernet TCP/IP
FAQ
Q: What is the main function of this module?
A: It connects Modicon Momentum devices to an Ethernet TCP/IP network.
Q: Can I use it outside?
A: No. It has IP20 protection. Use it in a clean, dry cabinet.
Q: How do I assign an IP address?
A: Use a BOOTP server. You can also assign a static IP.
Q: What is the maximum cable length?
A: The limit is 1,000 meters (3,280 feet) between devices.
Q: How many devices can share one segment?
A: You can connect 0 to 32 devices per segment.
Q: Does it come with a power supply?
A: No. You need to provide power separately.
Q: What is the lead time?
A: We ship in 12–24 hours via FedEx, UPS, or DHL.
Q: Is there a warranty?
A: Yes. 12-month warranty is included.
Q: I have never used BOOTP. Is it hard?
A: It is easy. Most engineers set it up in under 10 minutes.
Q: What if I need a different protocol?
A: This module only supports Ethernet TCP/IP. Look for other models for Modbus Plus or Profibus.
Q: Can I use a standard patch cable?
A: Use shielded twisted pair cable for best noise immunity.
Q: How do I know it is working?
A: Check the 4 LEDs. Three green and one yellow show link, activity, and errors.
Buying Guide
- Check your existing network speed. This module does 10/100 Mbit/s.
- Count your devices. Stay under 32 per segment.
- Measure cable runs. Keep under 1,000 meters.
- Confirm you have a BOOTP server or can assign a static IP.
- Make sure your enclosure meets IP20.
- Order if you need a fast, simple Ethernet adapter for Momentum.
- Contact us for bulk pricing or urgent shipping.
For inquiries: sales@powergearx.com or +86 18030005825 (WhatsApp).
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
















There are no reviews yet.