Product details
Product Overview
The 1606-XLS240E is a switched-mode power supply from the Allen-Bradley Bulletin 1606-XL series. It delivers a 24V DC output with 240W of power. A single-phase wide-range AC input covers 100 to 240V. The output adjusts from 24 to 28V DC and supplies up to 10A. Spring clamp terminals speed up wiring. A DC OK relay contact gives a simple status signal. BonusPower reserve power helps ride through short load peaks. This unit suits panel builders who need steady 24V rails.
Core Strengths
- Wide input range. One unit works on 100V to 240V AC lines.
- Adjustable output. Trim 24V up to 28V DC for line drop.
- Reserve power. BonusPower covers brief high-current bursts.
- Fast wiring. Spring clamp terminals cut install time.
- Simple status. The DC OK relay reports output health.
- Flexible mounting. Fits DIN rail or a flat wall.
Technical Specifications
- Brand: Allen-Bradley
- Model: 1606-XLS240E
- Series: Bulletin 1606-XL
- Module Type: Switched-mode power supply
- Output Voltage: 24V DC nominal, adjustable 24 to 28V DC
- Output Current: 10A maximum
- Rated Power: 240W
- Input Voltage: 100 to 240V AC nominal, single phase
- DC OK Signal: Relay contact present
- Reserve Power: BonusPower feature included
- Connection Type: Spring clamp terminals
- Mounting: DIN rail and wall mounting
- Operating Temperature: -25 to +70 °C
- Storage Temperature: -40 to +85 °C, non-operating
- Relative Humidity: 5 to 95 %
- Protection Rating: IP20
- Dimensions: 124 × 49 × 127 mm, unit body
- Weight: 0.78 kg
- Communication: None, DC OK relay contact only
Installation Guide
- Clip the unit onto a DIN rail or fix it to a flat wall.
- Keep clear space above and below for airflow.
- Feed 100 to 240V AC into the input terminals.
- Use spring clamps for a fast, tool-light wire fit.
- Set the output trim to the voltage your load needs.
- Wire the DC OK relay to your alarm or PLC input.
Setup and Maintenance
- Check the output LED after first power-up.
- Measure output at the terminals before loading.
- Confirm the DC OK contact changes state on fault.
- Clean the vents with dry air on a set schedule.
- Re-torque or reseat wires during yearly rounds.
Compatibility Notes
- Works with most 24V DC industrial loads.
- Fits standard DIN rail in control cabinets.
- No data bus. Use the relay contact for status only.
- Pairs well with Allen-Bradley Bulletin 1606 accessories.
Approvals and Standards
- UL 60950-1 listed.
- cUL certified for Canada.
- CE marked per Bulletin 1606 series standard.
- Lifecycle status: active on the official Rockwell page.
Package Contents
- One 1606-XLS240E power supply
- One quick start guide
- Protective packaging
FAQ
Q: Can this unit run on both 120V and 230V lines?
A: Yes. The wide-range input covers 100V to 240V AC.
Q: How much current can it deliver at 24V?
A: Up to 10A, which equals 240W of output power.
Q: Does it talk to a PLC over a network?
A: No. It has no data port. The DC OK relay is the only signal.
Q: What does BonusPower do for my load?
A: It supplies extra current for short peaks, such as motor starts.
Q: From experience, what causes a low output reading?
A: Loose spring clamps or a trim pot set too low. Check both first.
Q: From experience, how do I catch an overload early?
A: Wire the DC OK relay to an alarm. It flags trouble before a stop.
Q: From experience, why does the unit trip a breaker at start?
A: High inrush on cold start. Use a slow-blow breaker sized for it.
Q: Can I mount it sideways in a tight panel?
A: DIN rail and wall mounting both work. Keep airflow open.















There are no reviews yet.