Dettagli del prodotto
E82EV251K2C200 Lenze 8200 vector Frequency Inverter
E82EV251K2C200 is a Lenze 8200 vector built-in vector-controlled frequency inverter. It drives a 0.25kW 4-pole asynchronous motor in the 230 V class. The unit delivers 1.7 A nominal output current at 8 kHz. It handles 0…650Hz output frequency. This drive fits compact machines that need reliable speed and torque control. The C2xx variant ships senza filtro EMC integrato. A built-in brake transistor is included. The 8200 vector family is a legacy line. Lenze confirms a migration path to the i950 series. The i950 emulates 8200 vector behaviour through the i950 PROFIBUS module and the L_ICIP library.
Vantaggi principali
- Proven vector control for steady torque at low speed.
- 1.8 volte la coppia nominale overload for 60 s handles tough starts.
- Chopper di frenatura integrato cuts panel space and wiring.
- Flexible bus options cover most factory networks.
- Clear migration path to the i950 keeps your design future-proof.
Specifiche tecniche
- Marca: Lenze
- Modello: E82EV251K2C200
- Serie: vettore 8200
- Tipologia di prodotto: Inverter di frequenza a controllo vettoriale integrato
- Potenza nominale del motore: 0.25 kW tipici (motore asincrono a 4 poli)
- Corrente di uscita nominale: 1.7 A nominale alla frequenza di commutazione di 8 kHz
- massimo corrente di uscita: 2.5 A per 60 s (ciclo di variazione periodica del carico)
- Gamma di frequenza di uscita: 0…650Hz
- Frequenza di commutazione: 2/4/8/16 kHz selezionabili (impostazione di fabbrica 8 kHz)
- Classe di tensione di rete: 230 V
- Tensione di alimentazione: 1/N/PE 180…264 V AC (single-phase, 45…65 Hz)
- Versioni trifase: 3/PE 100…264 V CA
- Opzione di alimentazione CC: 260…370 V DC (except E82EV251/371 units)
- Capacità di sovraccarico: 1.8 volte la coppia nominale per 60 s
- Perdita di potenza: 30 W at Ir / 8 kHz (official 8200 vector catalogue 11/02 p.42)
- Filtro EMC integrato: No (C2xx variant)
- Transistor di frenatura integrato: Sì (chopper integrato fino a 11 kW)
- Porte integrate: Bus di sistema seriale RS232/485
- Protocolli: Bus di sistema Lenze; bus di campo tramite moduli plug-in
- Opzioni del bus di campo: PROFIBUS DP, CANopen, DeviceNet, INTERBUS, AS-Interface
- Slot di espansione: 2 control interfaces (3 slots above 15 kW)
- Temperatura di esercizio: -10…+55 °C (declassamento del 2.5%/°C al di sopra di +40 °C)
- Temperatura di conservazione: -25…+60°C
- Umidità relativa: Umidità relativa media dell'85%, nessuna condensa (classe climatica 3K3 secondo la norma EN 50178)
- Grado di protezione: IP20
- Dimensioni (H × W × D): 120 × 60 × 140 mm
- Peso: 0.8 kg
Guida all'installazione
- Mount the drive vertically on a flat panel. Keep the IP20 enclosure inside a cabinet.
- Reserve free space above and below for airflow. Heat rises, so never block the top.
- Use the single-phase 180…264 V AC supply for this 230 V class unit.
- Add an external EMC filter. This C2xx variant has no integrated filter.
- Tighten power terminals to the torque in the Lenze manual.
- Connect the brake resistor to the built-in chopper when you need fast stops.
- Keep motor cables short and screened. This lowers noise on the RS232/485 bus.
- Set the switching frequency to 8 kHz as a safe default. Raise it only when motor noise matters.
Messa in servizio e manutenzione
- Enter motor data from the nameplate. The drive then tunes itself to the motor.
- Use the Lenze keypad or a PC tool for fast parameter setup.
- Check the 1.8 x torque overload setting for your load cycle.
- Clean the heatsink every few months in dusty rooms. Dust blocks cooling.
- Inspect fan and terminal screws at each service visit.
- Log DC bus values to spot a weak brake resistor early.
- Keep spare plug-in modules on hand. Swap time is only minutes.
Note sulla compatibilità
- Works with standard 4-pole asynchronous motors in the 230 V class.
- Fits Lenze system bus networks out of the box.
- Aggiunge PROFIBUS DP, CANopen, DeviceNet, INTERBUS o AS-Interface tramite moduli plug-in.
- Two control interface slots allow mixed setups on one drive.
- No drop-in same-order-code replacement exists for newer drive lines.
- Official migration path: i950 with PROFIBUS module and L_ICIP library. Lenze AKB articles 321231 and 316137 cover this path for 8200 vector, 9300, 8400 and 9400.
- DC supply is not allowed on E82EV251/371 units. Check your unit code first.
Certificazioni e conformità
- Climatic class 3K3 per EN 50178 per l'umidità e l'ambiente.
- Designed for industrial cabinets with IP20 protection.
- EMC performance depends on an external filter. Plan it into the panel.
- Lifecycle status: official Lenze previous-products page is active. Last verified 2026-10.
Lista imballaggio
- 1 x E82EV251K2C200 inverter di frequenza
- 1 x printed quick-start guide
- 1 x terminal and connector set as shipped by Lenze
- Scatola protettiva con involucro antistatico
Garanzia e spedizione
- 12-mesi di garanzia sull'unità.
- Spedizione entro 12-24 ore dopo che il pagamento è stato accreditato.
- Opzioni Express: FedEx, UPS, DHL.
- Tracking number sent as soon as the parcel leaves our warehouse.
- Domande? Email sales@powergearx.com o chatta +86 18030005825 (WhatsApp).
Valutazione degli esperti
Migliori E82EV251K2C200 is a solid pick for small conveyors, pumps and fans that run on 230 V single phase. Vector control keeps torque steady at low speed. The built-in brake chopper saves panel space. The main limit is the missing EMC filter. Budget for an external filter and cabinet space. Buyers who plan a new line should compare the i950 path before locking in this legacy model.
Intuizione del manager
This drive sells well as a like-for-like spare. Plants with 8200 vector machines keep one on the shelf. Order the exact code E82EV251K2C200 to avoid wiring changes. For new builds, we advise the i950 with a PROFIBUS module. It copies 8200 vector behaviour and stays supported longer.
Applicazioni più adatte
- Small conveyors and packaging lines
- Pumps and fans with light variable loads
- Macchine tessili e per la lavorazione del legno
- Retrofit and spare-part service for 8200 vector panels
- Machines that need quick braking with a resistor
FAQ
- Does this unit include an EMC filter?
No. The C2xx variant ships without one. Add an external filter to meet EMC limits. - Can I use it on a 3-phase supply?
This model is for single-phase 180…264 V AC. Check the 3-phase versions for three-phase mains. - Qual è il sovraccarico massimo che può sopportare?
It delivers 1.8 x rated torque for 60 s. Size the motor with that in mind. - Is a brake resistor built in?
The brake transistor is built in. The resistor itself is external. - Can I feed it from a DC bus?
Yes on most units at 260…370 V DC. The E82EV251 and E82EV371 units are excluded. - How do I move to a newer drive?
Lenze confirms the i950 emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. - Quanto velocemente spedisci?
Orders leave in 12-24 hours by FedEx, UPS or DHL. - Qual è la garanzia?
12 mesi dalla consegna. - Experience tip: my motor hums at low speed.
Lower the switching frequency to 4 kHz and re-run motor identification. Hum often drops. - Experience tip: trips on start.
Check the overload setting against the 2.5 A for 60 s limit. A cold motor also needs more ramp time. - Buying guide: spare or new build?
Match the full code for spares. For new builds, price the i950 kit with its bus module first. - Buying guide: which bus module?
Pick the module your PLC already uses. One module type per network keeps spares simple.
Contatta il nostro team al sales@powergearx.com or +86 18030005825 for stock checks and migration advice.
Copyright © 2026 Powergear X Automation Limited. Tutti i diritti riservati.
Fonte originale: https://www.powergearx.com/















Non ci sono ancora recensioni.