उत्पाद विवरण
FCST2005 Fujikin Piezo Actuator Flow Controller for Reactive Gases
RSI एफसीएसटी2005 से फुजिकिन के अंतर्गत आता है एफसीएसटी टी2000 श्रृंखला. It is a piezo-actuated flow controller built for high-reactivity and low-stability gases. The diaphragm valve uses a gold-gasketed metal seal. This design limits particle generation and suits demanding semiconductor processes. The unit covers 5 SCCM से 5 SLM (N2 equivalent). A special 1-3 SCCM micro-flow option is also available. Accuracy reaches ±1% एसपी across 25-100% of set point. Analog 0-5 VDC and digital RS-485 or DeviceNet interfaces support easy integration. The standard version ships unheated for ambient operation.
तकनीकी डेटा
- ब्रांड: फुजिकिन
- आदर्श: एफसीएसटी2005
- सीरीज: एफसीएसटी टी2000 सीरीज (एफसीएस-टी2000 पीजो एक्चुएटर)
- पूर्ण पैमाने पर प्रवाह सीमा: 5 SCCM से 5 SLM (N2 समतुल्य)
- शुद्धता: ±1% एसपी (सेट पॉइंट का 25-100%); ±0.25% एफएस (2-25%)
- repeatability: FS 0.2% एफएस
- जवाब देने का समय: ≤1 सेकंड
- नियंत्रण सीमा (टर्नडाउन): 2-100% एफएस
- आपरेटिंग दबाव: Max 300 kPaG; required differential pressure 50-300 kPa; proof pressure 1 MPaG
- गीली सामग्री: SUS316L स्टेनलेस स्टील, PCTFE
- जवानों: धातु की सील (सोने की गैसकेट)
- वाल्व प्रकार: Piezo actuator diaphragm valve, N/O or N/C
- विद्युत इंटरफ़ेस: Analog 0-5 VDC (±15 VDC supply); Digital RS-485, DeviceNet
- बिजली की आपूर्ति: ±15 VDC; +15 VDC approx. 100 mA, -15 VDC approx. 50 mA
- परिचालन तापमान: 5-50 डिग्री सेल्सियस
- गर्म करने का विकल्प: नहीं (मानक बिना गर्म किया हुआ संस्करण)
- आयाम: 131 (ऊँचाई) × 124 (चौड़ाई) × 71 (गहराई) मिमी
- रिसाव अखंडता: ≤1×10⁻¹¹ Pa·m³/s He (बाहरी रिसाव)
- गैस के प्रकार: O3, halogen and reactive process gases; N2, Ar, He, H2 and semiconductor gases; special 1-3 SCCM micro-flow option
- अनुपालन: RoHS अनुरूप; CE; EP सतह फिनिश
मुख्य प्रदर्शन संबंधी नोट्स
- माप श्रेणी: 5 SCCM to 5 SLM covers micro and standard flows.
- प्रतिक्रिया: Settles within one second for fast process steps.
- Linearity and repeatability: ±1% S.P. accuracy and ±0.2% FS repeatability give stable dosing.
- संकल्प: Wide 2-100% FS control range supports fine adjustment.
- तापमान की रेंज: 5-50°C suits cleanroom and cabinet installs.
- पर्यावरण सहिष्णुता: Metal seals and SUS316L resist corrosive and oxidizing media.
- हस्तक्षेप प्रतिरोध: RS-485 digital signaling limits noise pickup in tool racks.
अधिष्ठापन गाइड
- Mount the unit on a clean, dry gas panel. Keep the base flat.
- Keep differential pressure between 50 and 300 kPa for stable control.
- Do not exceed 300 kPaG operating pressure or 1 MPaG proof pressure.
- Use compatible fittings. Flush lines before connection.
- Wire the ±15 VDC supply with correct polarity.
- Connect RS-485 or DeviceNet for digital control.
- Purge with dry N2 before reactive gas service.
सेटअप और रखरखाव में आसानी
- Zero and span checks run quickly through the analog interface.
- RS-485 allows remote setup and diagnostics.
- Metal-sealed diaphragm design reduces wear parts.
- Few components mean short service downtime.
- No heater keeps cabling and service simple.
- EP surface finish supports particle-sensitive lines.
अनुकूलता नोट्स
- Works with O3, halogens, and other reactive process gases.
- Handles N2, Ar, He, H2, and common semiconductor gases.
- Supports analog 0-5 VDC and digital RS-485 or DeviceNet hosts.
- Fits CVD, etch, flat panel display, and solar panel tools.
- PCTFE and SUS316L wetted parts match most corrosive gas lines.
प्रमाणन सूचना
- RoHS कॉम्प्लाइंट for restricted substance limits.
- CE marked for European market use.
- ईपी सतह फिनिश for high-purity gas paths.
- External leak rate meets ≤1×10⁻¹¹ Pa·m³/s He.
सूची पैकिंग
- 1 × FCST2005 flow controller
- 1 × अंशांकन प्रमाणपत्र
- 1 × operation manual
- 1 × connector kit for power and signal
- 1 × protective port caps
सामान्य प्रश्न
Q: Which gases can this controller handle?
A: It suits O3, halogens, and reactive process gases. It also works with N2, Ar, He, H2, and common semiconductor gases.
Q: What flow range does the FCST2005 cover?
A: The standard range is 5 SCCM to 5 SLM (N2 equivalent). A 1-3 SCCM micro-flow option exists for low-flow work.
Q: How accurate is the dosing?
A: Accuracy is ±1% S.P. from 25-100% of set point. From 2-25% it is ±0.25% FS. Repeatability is ±0.2% FS.
प्रश्न: क्या इसे गर्म जैकेट की आवश्यकता है?
A: No. The standard FCST2005 is unheated and runs at 5-50°C.
Q: What pressure does it need?
A: Keep differential pressure between 50 and 300 kPa. Maximum operating pressure is 300 kPaG.
प्रश्न: मैं इसे अपने उपकरण से कैसे कनेक्ट करूं?
A: Use the analog 0-5 VDC interface or digital RS-485 or DeviceNet. Supply is ±15 VDC.
Q: What does field experience show about uptime?
A: Users report stable control in O3 and etch lines. The metal seal and piezo drive limit drift. Most sites schedule annual zero checks and seal inspection.
Q: How do I handle a reactive gas line safely?
A: Purge with dry N2 before and after reactive service. Verify leak integrity at ≤1×10⁻¹¹ Pa·m³/s He before restart.
















अभी तक कोई समीक्षा नहीं।