Over 50,000 populære automatiseringsmodulkomponenter.

22A-A2P3H204 PowerFlex 4 Drive fra Allen-Bradley, 0.4 kW plade-VFD

0 anmeldelser
På lager
  • 100% ægte produkter på lager med hurtig levering.
  • 30-dages returret for kvalitetssikring.
  • 12 måneders garanti for ro i sindet.
SKU: 22A-A2P3H204
mærker:

Produkt detaljer

22A-A2P3H204 PowerFlex 4 AC Drive by Allen-Bradley

22A-A2P3H204 er en kompakt AC-drev fra Allen-Bradley, En del af PowerFlex 4 family. It takes single-phase 200…240 V input and gives 0.4 kW (0.5 HP) output at 2.3 A. A fixed keypad with LED display sits on the front. An RS-485 DSI port is built in. The drive ships as a replacement plate unit with IP20 open enclosure. It fits small machines that need simple speed control.

Tekniske data

  • Brand: Allen-Bradley (Rockwell Automation)
  • Model: 22A-A2P3H204
  • Serie: PowerFlex 4
  • Type: AC-frekvensomformer
  • Catalog code tree:
    • 22A — PowerFlex 4-familien
    • A — 240 V AC, 1-phase input
    • 2P3 — 2.3 A output, 0.4 kW / 0.5 HP
    • H — replacement plate drive, IP20 open type
    • 2 — interface module code
    • 0 — not filtered
    • 4 — standard type
  • Udgangseffekt: 0.4 kW (0.5 HP)
  • Kontinuerlig udgangsstrøm: 2.3 A
  • Udgangsspænding: 0…230 V, trefaset
  • Udgangsfrekvens: 0…240 Hz, programmerbar
  • Bærefrekvens: 2…16 kHz, nominel til 4 kHz
  • Overbelaste: 150 % i 60 sekunder, 200 % i 3 sekunder
  • Effektivitet: 97.5% typisk
  • Hastighedsregulering: ±2% af basishastighed, 40:1 område med slipkompensation
  • Accel and decel: two settings each, 0…600 s in 0.1 s steps
  • Stoptilstande: Rampe, Friløb, DC-bremse, Rampe-til-hold, S-kurve
  • Ramme størrelse: A
  • Køling: fan cooled for this rating

Kontrol I/O

  • Digitale indgange:
    • 3 dedicated: Stop, Start/Run FWD, Direction/Run REV
    • 2 programmerbare
    • 6 mA indgangsstrøm
    • SRC mode: 18…24 V DC = ON
    • SNK mode: 0…6 V DC = ON
  • Analog indgang:
    • 1 channel, DIP selectable
    • 0…10 V DC at 100 kΩ
    • 4…20 mA at 250 Ω
    • External pot: 1…10 kΩ, 2 W minimum
  • Relæudgang: 1 Form C, 3.0 A resistive, 0.5 A inductive
  • Encoderindgang: none published; the drive runs open loop only

Kommunikation

  • Indbygget port: 1 RS-485 DSI port
  • tilbehør: op til 2 pr. kørsel
  • Modbus RTU function codes:
    • 03 Read Holding Registers
    • 06 Write Single Register
    • 16 Write Multiple Registers
  • Network settings:
    • Node address A104: 1…247
    • Baud rate A103: 1200…38400 bit/s, default 9600
    • Format A107: RTU 8-N-1
    • Repeaters may be needed past 32 nodes
  • Udvidelse: no option-card slot; use the external DSI kit 22-XCOMM-DC-BASE instead
  • Fjernbetjeninger: 22-HIM-C2, 22-HIM-C2S, 22-HIM-A3

Elektrisk

  • Levere: 200…240 V AC, 1-phase, 50/60 Hz
  • Indgangstolerance: ± 10%
  • Indgangsområde: 180…265 V AC
  • Input rating: 1.15 kVA, 6.0 A, 10 A branch fuse
  • DC bus trip levels: 405 V overvoltage, 210 V undervoltage
  • Kraftfuld gennemkørsel: 100 ms fejlfri
  • Logik gennemgang: Minimum 0.5 s, typisk 2 s
  • Overstrøm: 200% hardwaregrænse, 300% øjeblikkelig fejl
  • Strømtab: 40 W i alt, 22 W ekstern plus 18 W intern
  • Bremsning: integral brake IGBT; external resistor of 60 Ω minimum, AK-R2-091P500 for 5% duty
  • EMC filter: none built in; L-type filter 22-RF010-AL for CE work

Miljøgrænser

  • Driftstemperatur:
    • -10…+50 °C for IP20 åben type
    • -10…+40 °C for IP30 / NEMA 1 with kit 22-JBAA
  • Opbevaring: -40 ... + 85 ° C
  • Fugtighed: 0…95%, no condensation
  • Chok: 15 g peak i 11 ms
  • Vibration: 1 g peak, 5…2000 Hz
  • Sund: 50 dBA ved 1 m
  • Højde: 1000 m uden derating
  • Luftkvalitet: keep away from corrosive gas, vapor and dust

Fysisk

  • Størrelse: 175.0 H × 104.8 B × 94.0 D mm
  • Vægt: 1.55 kg
  • Montering: replacement plate, fits inside a cabinet cutout

Bedst passende enheder og applikationer

  • Små transportbånd og indekseringsborde
  • Fans and blowers in light HVAC work
  • Pumps with gentle ramp needs
  • Blandere og omrørere på små tanke
  • Emballerings- og etiketteringsmaskiner
  • Dør- og portmotorer
  • Machine retrofits where a plate drive drops into an old cutout

Installationsvejledning

  • Cut the panel opening to the plate size, then fix the plate with its screws.
  • Keep the heatsink clear; this unit relies on fan airflow.
  • Use the 10 A branch fuse stated in the ratings table.
  • Add the 22-JBAA kit when the site needs NEMA 1 protection.
  • Fit the 22-RF010-AL line filter when CE EMC limits apply.
  • Shield motor cable or keep it short; 10 m is the CE limit with a filter.

Opsætning og vedligeholdelse

  • Set motor data in the parameter list before the first run.
  • Tune accel and decel times to suit the load.
  • Check fan airflow at each service visit.
  • Copy settings to spare drives through the DSI port.

Specifikationer

  • cULus-godkendt i henhold til UL 508C og CSA C22.2 nr. 14
  • CE to EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
  • KC registration KCC-REM-RAA-22A
  • Ecodesign (EU) 2019/1781 and UK SI 2021 No. 745, IE2 class met
  • No Safe Torque Off, no UL Type 4X, no seismic rating published

Pakkeliste

  • Én 22A-A2P3H204 drive, frame A
  • One replacement plate and fixing screws
  • One user manual 22A-UM001L-EN-E
  • One safety information sheet

Ofte stillede spørgsmål

Q: My old drive used a plate mount. Will this unit drop into the same hole?

A: Usually yes, if the cutout matches the 175 × 104.8 mm plate. Measure the old opening first, because frame A plates follow one size only.

Q: The motor hums at low speed. What should I try first?

A: Raise parameter A091 above the 4 kHz default. A higher carrier frequency quiets the motor, though it adds heat inside the drive.

Q: Can I run this drive from a 120 V outlet?

A: No. This catalog number needs 200…240 V single-phase. For 120 V sites, order the 100…120 V voltage code instead.

Q: How do I stop a long conveyor without the load rolling on?

A: Pick Ramp-to-Hold in P037. The drive holds torque at zero speed, so the belt stays put until you release it.

Q: A nearby panel needs network control. What is the cheapest path?

A: Use the built-in RS-485 port with Modbus RTU. For DeviceNet, ControlNet or EtherNet/IP, add the 22-XCOMM-DC-BASE kit with the right adapter.

Q: Should I worry about harmonics on a public grid?

A: Often yes. The manual lists the drive for private low-voltage networks. On a public network, add external harmonic mitigation and check with the utility.

Q: Does the drive keep running through a short power dip?

A: It rides through 100 ms of power loss and holds logic for 0.5 s minimum. Longer dips will trip the drive, so plan a restart routine.

Specifikationer

  • MærkeAllen-Bradley
  • VarenummerATV930U40N4
  • BetingelseOriginal splinterny

Kundeanmeldelser

Der er endnu ingen anmeldelser.

Be the first to review “22A-A2P3H204 PowerFlex 4 Drive by Allen-Bradley, 0.4 kW Plate VFD”

Din e-mailadresse vil ikke blive offentliggjort. Obligatoriske felter er markeret med *

Tilbage til toppen
Produktet er føjet til din indkøbskurv