,en Fujikin FCST2150 is a high-flow digital mass flow controller. It belongs to the Серыя FCST T2150. This unit handles Ад 51 да 150 SLM of N2 equivalent flow. A электрамагнітны прывад drives the diaphragm valve. The valve is normally closed. A metal seal with a gold gasket protects gas purity. The body uses SUS316L stainless steel. This model suits high-flow semiconductor gas delivery, CVD chamber purge, and bulk gas distribution. The FCST2150 delivers Дакладнасць ±2% ад поўнага дыяпазону і ±0.2% FS repeatability. Response time stays within one second. The design is compact and RoHS compliant. It also carries CE marking. Choose this model for stable, high-flow control in reactive gas lines.
Тэхнічныя характарыстыкі
- Марка: Фудзікін
- мадэль: FCST2150
- Серыя: FCST T2150 Series (FCS-T2150 High Flow Piezo/Solenoid)
- Поўны дыяпазон расходу: 51 to 150 SLM (N2 equivalent)
- дакладнасць: ± 2% ФС
- Паўтаральнасць: ± 0.2% ФС
- Час водгуку: ≤1 секунда
- Дыяпазон рэгулявання: Ад 2 да 100% поўнага дыяпазону
- Тыпы газу: N2, Ar, He, and semiconductor process gases
- Працоўны ціск: max 400 kPaG
- Неабходны перапад ціску: 200 to 350 kPa (51 to 100 SLM), 250 to 350 kPa (101 to 150 SLM)
- Ціск доказу: 1 МПаГ
- Змочваюцца матэрыялы: SUS316L stainless steel, PCTFE, FKM
- Пячатка: metal seal with Au gold gasket
- Тып клапана: solenoid actuator, diaphragm valve, N/C only
- Электрычны інтэрфейс: analog 0 to 5 VDC, ±15 VDC supply
- Спажыванне энергіі: +15 VDC approx. 100 mA, -15 VDC approx. 200 mA
- Працоўная тэмпература: 5 да 50 ° C
- Варыянт з падагрэвам: не, стандартная версія без падагрэву
- памеры: 136 (H) x 163.4 (W) x 108 (D) mm
- Фітынгі: 3/8 UJR
- External leak integrity: ≤1×10⁻¹¹ Па·м³/с He
- паверхню: Паверхневая аздабленне EP
Ключавыя заўвагі па прадукцыйнасці
- Дыяпазон вымярэнняў: wide 51 to 150 SLM span covers most high-flow tools.
- Частотны дыяпазон: full stroke settles in one second or less.
- Linearity and sensitivity: ±2% FS accuracy supports repeatable process recipes.
- дазвол: 2 to 100% FS control range gives fine low-end trim.
- Тэмпературны дыяпазон: 5 to 50°C suits cleanroom and cabinet installs.
- Устойлівасць да ўздзеяння навакольнага асяроддзя: proof pressure of 1 MPaG adds safety margin.
- Перашкодаўстойлівасць: analog 0 to 5 VDC signal works with shielded cabling.
Кіраўніцтва па ўстаноўцы
- Змантаваць FCST2150 in any stable orientation.
- Keep the unit level for best zero stability.
- Выкарыстоўваць 3/8 UJR fittings for leak-tight joints.
- Confirm differential pressure before power-up.
- Set 200 to 350 kPa for flows of 51 to 100 SLM.
- Set 250 to 350 kPa for flows of 101 to 150 SLM.
- Провад ±15 В пастаяннага току to the correct pins.
- Route the analog signal away from power cables.
- Purge the line with dry N2 before first run.
- Check for external leaks after assembly.
Настройка і абслугоўванне
- Zero the analog output at no flow.
- Calibrate against a certified flow standard.
- Log drift values during scheduled checks.
- Заменіце Au gold gasket at service intervals.
- Трымайце metal seal free of particles.
- Use dry, oil-free gas only.
- Store spare parts in clean bags.
- The compact body eases in-cabinet access.
сумяшчальнасць
- Працуе са стандартам 0 да 5 пастаяннага току аналагавыя кантролеры.
- прыступы 3/8 UJR gas panels and manifolds.
- Handles N2, Ar, He, and common semiconductor gases.
- Matches Fujikin T2000 series gas panel layouts.
- Pairs with EP-finish tubing for purity loops.
Сертыфікацыя і адпаведнасць
- RoHS сумяшчальны.
- CE пазначаны.
- Паверхневая аздабленне EP for high-purity service.
ўпаковачны ліст
- Адзін Fujikin FCST2150 рэгулятар масавага расходу.
- Адзін сертыфікат каліброўкі.
- Адно кароткае кіраўніцтва па пачатку.
- One fitting kit for 3/8 UJR ports.
- One protective cap set.
Часта задаваныя пытанні
- Q: Can I run this unit at 150 SLM with low inlet pressure?
A: No. You need 250 to 350 kPa differential pressure at that flow. - Q: Is the valve normally open?
A: No. The FCST2150 ships as N/C only. - Q: Does it come with a heater?
A: Не. Гэта стандартная версія без падагрэву. - Q: How often should I check zero drift?
A: Most fabs check monthly during the first year. - Q: What causes slow response in the field?
A: A clogged inlet filter or low differential pressure is the usual cause. - Q: Can I swap this unit with a T2000 low-flow model?
A: Check pressure and fitting match first. Flow span differs. - Q: Why does my reading drift after a gas change?
A: Gas correction factors differ. Recalibrate for the new gas. - Q: What is the most common install mistake?
A: Reversed flow direction and unshielded signal wiring.

















Там няма ні аднаго водгуку.