- FCST1005MF-HT is a heated mass flow controller from Fujikin.
- -a aiddir FCST T1000 Seriyası.
- Moreover, the heated flow path holds 50 ° C ilə 80 ° C arasında.
- Therefore, it stops condensation in condensable gas lines.
- In addition, a metal Au gasket seal gives very low leak rates.
- As a result, it suits liquefied sources and high-vapor-pressure gases.
- It also fits CVD and etch tools with heated delivery.
- Finally, this product is cari və təsdiqlənib November 2026.
Texniki Features
- Brand: Fujikin
- Model: FCST1005MF-HT
- Series: FCST T1000 Seriyası Yüksək temperatur
- Tam miqyaslı axın diapazonu: 10 SCCM to 5 SLM, N2 equivalent
- Qaz növləri: customer-specified process gas; heated for condensable and high-vapor-pressure gases
- Dəqiqlik: ±1% FS from 2% to 100% FS
- Təkrarlanma: ±% 0.2 FS
- Cavab müddəti: 1 saniyə və ya daha az
- Dizayn: covered within ±1% FS accuracy
- Sensitivity and resolution: tuned for low-flow control from 10 SCCM
- Nəzarət aralığı: 2% to 100% FS turndown
- Əməliyyat temperatur: 50 ° C ilə 80 ° C arasında heated; custom calibration temperature available
- İşləmə təzyiqi: maximum 400 kPaG
- Islanmış materiallar: SUS316L stainless steel with PCTFE seats
- Möhürlər: metal Au gasket
- Valf növü: normal olaraq açıq və ya normal olaraq bağlı olan, körüklü metal diafraqma klapanı
- Sızma bütövlüyü: ≤1×10⁻¹¹ Pa·m³/s He with metal seal
- Ölçü: 125 H × 124 E × 70 D mm
- Elektrik interfeysi: analog 0-5 VDC with ±15 VDC supply; +24 VDC option with 0-5 VDC or 4-20 mA; digital RS-485 and DeviceNet on T1000MF models
- Elektrik təchizatı: ±15 VDC for 0-5 VDC analog; +24 VDC option
- Ətraf mühitə müqavimət: stable control across the heated range
- Müdaxilə müqaviməti: CE marked for industrial use
Quraşdırma Kılavuzu
- First, mount the unit in a clean, dry location.
- Then leave space for the heated body and airflow.
- Next, confirm line pressure stays at or below 400 kPaG.
- After that, connect ±15 VDC or +24 VDC power as ordered.
- Then wire the analog or digital signal per the site plan.
- Also use metal gasket fittings for tight joints.
- Before gas flows, check external leak integrity.
- Finally, warm the flow path to setpoint before calibration.
Quraşdırma və Baxım Rahatlığı
- Moreover, the heated body removes cold spots in vapor lines.
- Therefore, users avoid condensation and clogging.
- In addition, the remote control substrate option eases panel layout.
- Also, the metal diaphragm valve limits wear and particle risk.
- Furthermore, analog and digital options ease controller swaps.
- Meanwhile, the EP surface finish supports clean service.
- As a result, routine checks focus on zero, heat, and leak tests.
Uyğunluq Qeydləri
- Works with 0-5 VDC and 4-20 mA control systems.
- In addition, it supports RS-485 and DeviceNet on T1000MF models.
- Moreover, it fits condensable and high-vapor-pressure gases.
- Also, it suits CVD and etch tools with heated delivery lines.
- Furthermore, metal Au gasket seals match high-purity panels.
- However, users must supply heater and control power as specified.
- Therefore, review gas dew point before setting temperature.
Sertifikatlar
- CE işarələnmiş.
- Həm də belədir RoHS uyğun.
- Moreover, the EP surface finish meets clean gas delivery needs.
Siyahısı Qablaşdırma
- Bir Fujikin FCST1005MF-HT heated MFC.
- Also, one configuration label with model and range data.
- In addition, one quick start guide.
- Moreover, one certificate of compliance.
- Furthermore, interface and valve options as ordered.
- Finally, cables and accessories only if selected.
FAQ
- Why does this model need heat?
The heater keeps the flow path at 50°C to 80°C. Therefore, condensable gases stay vaporized and do not clog lines. - How tight is the seal?
It uses a metal Au gasket. As a result, leak integrity reaches ≤1×10⁻¹¹ Pa·m³/s He. - What flow range does it cover?
It covers 10 SCCM to 5 SLM of N2 equivalent. Moreover, accuracy stays at ±1% FS from 2% to 100%. - Which interfaces can I order?
Analog 0-5 VDC and 4-20 mA are available. In addition, RS-485 and DeviceNet come on T1000MF models. - Can I set a custom calibration temperature?
Yes. The factory can calibrate at a customer-specified temperature. However, confirm this at order time. - Quraşdırma zamanı nəyi yoxlamalıyam?
First, confirm line pressure stays below 400 kPaG. Also check seal tightness and heater wiring before warm-up. - What is a common field experience issue?
Slow warm-up often causes early condensation. Therefore, wait for full heat soak before opening process gas. - Which valve action should I pick?
Both normally open and normally closed are offered. Therefore, choose based on your fail-safe plan.