Product details
Produk Hoogtepunte
- model 22A-A4P5H204 is a PowerFlex 4 AC drive from Allen-Bradley / Rockwell Automation.
- Dit neem single-phase 200…240 V AC input and gives 0.75 kW (1 HP) output at 4.5 A.
- Uitset is three-phase 0…230 V met 'n frekwensiebereik van 0…240 XNUMX Hz.
- Die replacement plate design fits right into existing panel cutouts.
- An integrale rem IGBT is built in for fast stops.
- A ingeboude RS-485 DSI-poort supports Modbus RTU networking.
- Hierdie is 'n compact, low-cost choice for simple motor control.
Tegniese data
- Handelsmerk en model
- Merk: Allen-Bradley (Rockwell Automation)
- model: 22A-A4P5H204
- Reeks: PowerFlex 4 (22A)
- tipe: WS-verstelbare frekwensie-aandrywer
- Catalog code breakdown
- 22A = PowerFlex 4 family
- A = 240 V AC, single-phase
- 4P5 = 4.5 A output, 0.75 kW
- H = replacement plate, IP20 open type
- 2 = interface module code
- 0 = not filtered
- 4 = standard build
- Krag en beheer
- Uitset krag: 0.75 kW (1 HP)
- Deurlopende uitset: Die 4.5
- Draer frekwensie: 2…16 kHz, default 4 kHz
- oorlading: 150% vir 60 s; 200% for 3 s
- Doeltreffendheid: 97.5% tipies
- Spoedregulering: ± 2% with slip compensation
- Ramp times: 0…600 s, two sets
- Stopmodusse: Oprit, Uitrol, GS-rem, Oprit-na-Hou, S-kromme
- Insette en uitsette
- Digitale insette: 3 fixed + 2 programmable
- Analoog insette: 1, 0…10 V or 4…20 mA, DIP-selectable
- Aflos uitset: 1 Vorm C, 3.0 A resistive at 30 V DC / 240 V AC
- Elektriese
- Invoerreeks: 180…265 V AC, single-phase, 50/60 Hz
- Invoerstroom: Die 10.0, 2.25 kVA, 15 A fuse
- Kragdeurrit: 100 Me
- Overcurrent limit: 200% hardware, 300% trip
- Hitte verlies: 55 W total at rated load
- omgewing
- Looptemperatuur: -10 ...+50 ° C for open type; +40 °C for NEMA 1
- Storage: -40 ...+85 ° C
- Humiditeit: 0…95% nie-kondenserend
- skok: 15 g / 11 ms; vibration: 1 g, 5…2000 Hz
- Geraas: 50 dBA op 1 m
- Hoogte: 1000 m sonder ontslag
- Keep the air free of corrosive gas, vapor, or dust
- Fisiese
- grootte: 175.0 × × 104.8 94.0 mm algehele
- Gewig: 1.58 kg
- Frame: A
- Afkoeling: fan cooled
- Network and options
- Port: 1 × RS-485 DSI, up to 2 peripherals
- Protokol: Modbus RTU, codes 03, 06, 16
- nodes: 1 ... 247; speed: 1200…38400 bit/s
- Filters: use external L type 22-RF010-AL vir CE
- NEMA 1 kit: 22-JBAA
- Remweerstand: 60 Ω min, AK-R2-091P500
Waar Dit Pas
- Klein vervoerbande and package handling lines
- Aanhangers en blasers in light duty rooms
- Pompe for water supply and sumps
- Mengers en roerders on small tanks
- Masjien gereedskap and simple spindle drives
- Door and gate bewegingsbeheer
- Food and packing equipment in dry areas
- heraanpassing where a plate drive drops into an old cutout
Installeer gids
- Mount the plate into the panel cutout and fix the screws.
- Hou die heatsink clear so air can flow.
- Set input voltage with the DIP-skakelaars voor aanskakeling.
- Gebruik 15 A branch fuse or a listed motor protector.
- Voeg 'n external filter when CE limits apply.
- Wire the RS-485 link with afsluitweerstande at the ends.
- Voeg 'n external brake resistor for fast stops.
Opstelling en versorging
- Die LED-sleutelbord shows faults and settings on the spot.
- Set ramp and stop mode with simple parameters.
- Gaan die fan and heatsink at each service visit.
- Clear dust from the vents to vermy oorverhitting.
- The plate design allows quick swap without rewiring the panel.
Certificaties
- cULus gelys volgens UL 508C en CSA C22.2 No. 14
- CE: EMC 2014/30/EU and LVD 2014/35/EU
- KC mark: KCC-REM-RAA-22A
- IE2 efficiency under EU 2019/1781
- Geen Veilige wringkrag af en nee seismiese rating published
Pak lys
- 22A-A4P5H204 replacement plate drive
- vaste LED-sleutelbord
- Installasie handleiding 22A-UM001L-EN-E
- Gewig: 1.58 kg
FAQ
- Q: Will this drive run a three-phase motor from a single-phase line?
- A: Yes. It makes three-phase 0…230 V output from one-phase input.
- Q: Can I control it from a PLC over Modbus?
- A: Yes. The DSI port speaks Modbus RTU with codes 03, 06, and 16.
- Q: Do I need a separate filter for CE?
- A: Yes. This build has no internal filter. Add the L type unit.
- Q: From field practice, why does the drive trip on long motor cables?
- A: Cable length adds capacitance. Keep runs short and fit a filter.
- Q: From field practice, what causes a fast stop to fault?
- A: The brake resistor is too small or the stop time is too short.
- Q: From field practice, how do I cut RF noise in a panel?
- A: Use shielded cable. Bond the shield at both ends to PE.















Daar is nog geen resensies nie.